Eaton P3BEHD3060GN Pow-R-Way III - 18 kAIC at 240 Vac
Part Number: P3BEHD3060GN
Quick Summary
The Eaton Pow-R-Way III circuit breaker plug-in unit protects busway feeds while simplifying installation in industrial power-distribution systems. Engineers frequently contend with complex wiring, uneven grounding, and balancing neutral paths; this unit addresses those challenges with 100% neutral and a 50% internal ground option. It carries UL 857, IEEE, CSA, and ANSI certifications, enabling compliant deployments across varied facility environments. By pairing a compact three-pole E-frame design with a 60A rating and 18 kAIC at 240 Vac, it delivers reliable fault protection and predictable maintenance cycles. For procurement teams, the solution also offers a familiar Eaton warranty and strong lifecycle economics through reduced downtime and easier spares management.
Product Information
Extended Description
P3BEHD3060GN Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, EHD, Plug, Breaker, E Frame (15-225 A), 60A, 18 kAIC at 240 Vac, 14 kAIC at 480 Vac, 100% Neutral, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BEHD3060GN
UPC
786683005685
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
UL 857 IEEE Certified CSA Certified ANSI
Circuit Breaker Frame
E
Design
Pow-R-Way III
Grounding Options
50% Internal
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
60A
Interrupt rating
18 kAIC at 240 Vac, 14 kAIC at 480 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Feature: Three-pole E-frame plug-in design compatible with Pow-R-Way busway. Business impact: streamlines installation and minimizes field wiring errors by using standardized mounting and terminals. Application: ideal for rapid deployment in busway distribution projects across automotive, food & beverage, and general industrial facilities. Feature: 60A amperage rating with 18 kAIC at 240 Vac and 14 kAIC at 480 Vac. Business impact: higher fault-tolerance protects downstream equipment and reduces damage risk. Application: suitable for motor loads and feeders in mid-size industrial systems. Feature: 100% Neutral with 50% internal grounding. Business impact: improves fault path clarity and safety, simplifying protective-device coordination. Application: essential for systems requiring robust grounding schemes in multi-branch busways. Feature: UL 857, IEEE, CSA, ANSI certifications and NEMA compliance. Business impact: ensures regulatory alignment and easier supplier qualification, reducing audit delays. Application: global manufacturing setups and compliant electrical rooms. Feature: Plug-in unit for easy replacement and maintenance within existing busway structures. Business impact: minimizes downtime during maintenance and parts replacement; reduces total cost of ownership. Application: OEMs and service teams integrating Pow-R-Way III into standard power-distribution assemblies. Warranty and support: Eaton’s 25-000 policy provides a one-year minimum from installation or eighteen months from shipment, whichever occurs first, supporting ongoing reliability and serviceability.
Get a Quick Quote for a Eaton P3BEHD3060GN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BEHD3060GN?
Enquire Now
FAQs
Installers should verify busway alignment and mounting clearances, ensure correct plug-in mounting on the E-frame assembly, and connect the neutral path to maintain 100% neutral. Confirm grounding scheme adheres to 50% internal grounding as specified, and follow the unit’s NEMA-compliant guidelines to support safe, reliable protection of busway feeders.
The P3BEHD3060GN provides a 60A amperage rating with 18 kAIC at 240 Vac and 14 kAIC at 480 Vac. It is UL 857 and IEEE certified, with CSA and ANSI certifications, and is NEMA compliant, ensuring broad regulatory compatibility and market acceptance across regions.
Yes. The unit is designed as a three-pole E-frame plug-in configuration, optimized for Pow-R-Way III busway systems. This compatibility simplifies replacement and upgrades within existing busway architectures while preserving protective coordination and mechanical fit.
With 100% neutral, 50% internal grounding, and a robust 60A/18 kAIC at 240Vac protection profile, the device enhances fault detection and clears faults quickly, reducing downtime. The plug-in design also streamlines replacement and maintenance tasks, lowering labor costs and ensuring quicker field service.
The unit is covered by Eaton’s warranty policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. This ensures post-installation support, predictable service intervals, and access to Eaton’s technical resources for ongoing reliability and spare availability.