Eaton P3BFD3030SP Pow-R-Way III breaker - UL/CSA

Part Number: P3BFD3030SP
Manufacturer
Eaton
Part number
P3BFD3030SP

Quick Summary

Pow-R-Way III circuit breaker plug-in unit provides reliable overcurrent protection for busway-powered electrical installations. Engineers often face sprinkler-proof plug-in reliability and field-replacement challenges in evolving busway architectures. This unit carries UL 857, IEEE Certified, CSA Certified, and ANSI listings, aligning with strong industrial safety and cross-vendor compatibility. By leveraging its three-pole F-frame design and sprinkler-proof plug-in features, it delivers scalable protection with reduced maintenance downtime, fitting seamlessly into modern power distribution schemes and helping minimize total cost of ownership.

Product Information

Extended Description

P3BFD3030SP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Sprinkler-proof plug-in, Busway, Three-pole, FD, Plug, Breaker, F Frame (15-225 A), 30A, 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BFD3030SP
UPC
786685380322
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
UL 857 IEEE Certified CSA Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
30A
Interrupt rating
65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Special features
Sprinkler-proof plug-in
Sprinkler-proof plug-in design provides safe, field-replaceable protection in sprinkler-rated environments, reducing installation risk and downtime while simplifying maintenance in critical facilities. This contributes to improved safety compliance and faster fault isolation in busway layouts, enabling technicians to swap modules without rewiring. The 30A amperage rating with 65 kAIC at 240 VAC, 25 kAIC at 480 VAC, and 18 kAIC at 600 VAC delivers robust short-circuit protection for compact power distribution footprints, supporting reliable operation of motors and drives in plant floors and data centers. Three-pole, F-frame construction with 50% integral/housing grounding offers dependable three-phase protection and flexible grounding options, streamlining integration with existing busway systems and minimizing grounding complexity. The plug-in design, coupled with NEMA compliance and compatibility with Pow-R-Way III busways, reduces installation time and potential wiring errors, while the sprinkler-proof feature adds resilience in safety-critical applications. Certifications (UL 857, IEEE, CSA, ANSI) simplify procurement and regulatory alignment, helping aerospace, food & beverage, and manufacturing environments maintain compliance without vendor lock-in. The included warranty (one year from installation or eighteen months from shipment) provides added assurance for long-term return on investment.

Get a Quick Quote for a Eaton P3BFD3030SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BFD3030SP? Enquire Now

FAQs

Yes. The P3BFD3030SP is designed as a sprinkler-proof plug-in circuit breaker for Pow-R-Way III busways, featuring a three-pole F-frame configuration and grounding options that align with standard Eaton busway installations. Its plug-in design reduces field wiring and speeds commissioning while maintaining NEMA compliance.
The unit provides 65 kAIC at 240 VAC, 25 kAIC at 480 VAC, and 18 kAIC at 600 VAC with a 30A rating. Specify these ratings to match your system fault current levels and motor inrush profiles, ensuring rapid fault isolation and preventing equipment damage in three-phase busway distributions.
Yes. The device carries UL 857, IEEE Certified, CSA Certified, and ANSI listings, supporting safety compliance and interoperability across vendors. This simplifies regulatory approvals for plant electrical rooms, data centers, and manufacturing facilities that require validated, standards-based protection.
The sprinkler-proof plug-in design streamlines replacements with minimal downtime and reduced wiring, lowering maintenance labor costs and improving mean time to repair (MTTR). Combined with strong interrupt ratings and modularity, it enables scalable protection that adapts to changing busway configurations, delivering a faster return on investment through reduced downtime.
The unit is a three-pole, F-frame breaker with 50% integral/housing grounding. It weighs 25 lb and fits within a 12.36 in depth, 21.2 in height, and 5.43 in width footprint. Plan for these dimensions and grounding option to ensure clean integration with existing busways and to simplify grounding conductor routing.