Eaton P3BFD3040NSP Plug-in Circuit Breaker - 65 kAIC

Part Number: P3BFD3040NSP
Manufacturer
Eaton
Part number
P3BFD3040NSP

Quick Summary

The Eaton P3BFD3040NSP plug-in circuit breaker protects busway systems in industrial environments. Engineers often face sprinkler-proof environments, tight spaces, and slow retrofits that complicate protection upgrades. It carries ANSI, CSA, UL 857, and IEEE certifications, plus NEMA compliance, delivering reliable regulatory alignment. Designed for Pow-R-Way III busway installations, its 100% neutral and 50% integral grounding simplify wiring and maintenance while delivering robust fault protection. This combination supports safer, faster project execution and long-term operating efficiency for critical power distribution.

Product Information

Extended Description

P3BFD3040NSP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit,Sprinkler-proof plug,Busway,Three-pole,FD,Plug,Breaker,F Frame (15-225 A),40A,65 kAIC at 240 Vac,25 kAIC at 480 Vac,18 kAIC at 600 Vac,100% Neutral,50% Integral/Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BFD3040NSP
UPC
786685180052
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI CSA Certified UL 857 IEEE Certified
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
40A
Interrupt rating
65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Special features
Sprinkler-proof plug-in
Three-pole, F-frame design provides consistent three-phase protection for busway runs, reducing coordination errors and arc-flash risk. The business impact is safer commissioning and smoother maintenance, especially in dense plant layouts where space constraints are common. This is ideal for Pow-R-Way III installations where reliable phase balance is crucial. Sprinkler-proof plug-in construction minimizes moisture ingress and foreign-object intrusion, delivering higher uptime in facilities with fire suppression requirements. The resulting benefit is lower unplanned downtime and fewer field re-works during maintenance windows, particularly in harsh environments or high-humidity areas. The unit offers 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, and 18 kAIC at 600 Vac, enabling fault-current withstand for robust industrial profiles. This translates to improved protection for heavy machinery, conveyors, and automation panels with high short-circuit demands. Its 100% Neutral option and 50% Integral/Housing grounding simplify grounding schemes, reducing wiring complexity and installation time across multi-panel busways. In practice, technicians appreciate quick plug-in mounting, standardized busway integration, and consistent performance across varying fault levels. With a compact footprint—12.36 in long, 21.2 in high, 5.43 in wide—and a modest 25 lb weight—the P3BFD3040NSP fits standard enclosures and supports safer, faster retrofits in evolving facilities. The design aligns with NEMA compliance and provides a dependable, scalable solution for growing power distribution needs.

Get a Quick Quote for a Eaton P3BFD3040NSP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BFD3040NSP? Enquire Now

FAQs

Install as a three-pole plug-in unit designed for Pow-R-Way III busways. Ensure proper alignment with the busway interface, attach to a compatible enclosure, and connect the grounding strap per the 50% integral/housing grounding option. Verify 100% neutral termination and secure mounting to prevent vibration or loosening under load. Always follow Eaton installation guidelines for safe commissioning.
The device is rated at 40A with interrupt ratings of 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, and 18 kAIC at 600 Vac. It is a three-pole, F-frame design featuring 100% neutral and 50% integral grounding. These specs enable reliable fault current handling across typical industrial duty cycles while maintaining coordination with other Pow-R-Way III breakers.
Yes. The unit features a sprinkler-proof plug design and is built for use in spaces with fire suppression systems. This adds an extra layer of protection against moisture and debris, reducing maintenance issues and improving uptime in facilities with sprinkler installations.
The P3BFD3040NSP carries ANSI, CSA certification, UL 857, and IEEE certification, along with NEMA compliance. These certifications help with regulatory audits, safety assurances, and compatibility with broad industrial standards, simplifying procurement and system integration.
Adoption delivers faster installation, standardized Pow-R-Way III integration, and improved uptime due to sprinkler-proof design and reliable fault protection. The unit’s grounding options and 100% neutral simplify wiring, while its compact footprint supports space-efficient panel layouts, reducing both capex and Opex over the system lifecycle.