Eaton P3BFD3060NSP circuit breaker plug-in unit - NEMA

Part Number: P3BFD3060NSP
Manufacturer
Eaton
Part number
P3BFD3060NSP

Quick Summary

Eaton P3BFD3060NSP circuit breaker plug-in unit protects busway systems in industrial power distribution. Maintenance downtime and arc-flash risk rise when breakers aren’t easily serviceable or properly grounded. CSA, IEEE, and UL certifications underscore safety and compliance across North American installations. With 60 A ratings and 65 kAIC interrupt capability, it supports scalable, code-compliant power distribution while reducing total cost of ownership. Designed for sprinkler-proof plug-in assemblies and full busway compatibility, it minimizes field rework and accelerates panel builds. Its 100% Neutral option and 50% integral grounding streamline installation in complex electrical rooms. Warranty Coverage follows Eaton policy with support from a global service network.

Product Information

Extended Description

P3BFD3060NSP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit,Sprinkler-proof plug,Busway,Three-pole,FD,Plug,Breaker,F Frame (15-225 A),60A,65 kAIC at 240 Vac,25 kAIC at 480 Vac,18 kAIC at 600 Vac,100% Neutral,50% Integral/Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BFD3060NSP
UPC
786685180076
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
CSA Certified IEEE Certified UL 857 ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
60A
Interrupt rating
65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Special features
Sprinkler-proof plug-in
Feature: Sprinkler-proof plug-in design for Pow-R-Way III breakers and busway assemblies. Impact: Reduces moisture ingress and corrosion risk, increasing reliability and reducing maintenance downtime in challenging environments. Application: Ideal for life-safety zones, selected outdoor installations, and humid factory floors where water exposure is a concern. Feature: 60A amperage rating with substantial interrupt capability (65 kAIC at 240 VAC, 25 kAIC at 480 VAC, 18 kAIC at 600 VAC). Impact: Provides robust short-circuit protection with high fault current tolerance, protecting downstream equipment and improving overall system uptime. Application: Suitable for medium-size feeders and modular power distribution schemes in manufacturing lines. Feature: 100% Neutral and 50% Integral/Housing Ground options. Impact: Enhances fault-clearing performance and simplifies chassis grounding schemes, reducing installation complexity. Application: Critical for multi-panel busway configurations and safer neutral distribution in complex panels. Feature: Busway-compatible plug-in design with three-pole configuration. Impact: Speeds up installation, facilitates modular expansions, and minimizes field wiring errors. Application: Perfect for data centers, warehouses, and process plants using Eaton Pow-R-Way III busways. Feature: Comprehensive compliance footprint (CSA, IEEE, UL 857, ANSI; NEMA Compliant). Impact: Eases regulatory approvals and helps meet stringent industry standards across North America. Application: Essential for regulated facilities in oil, gas, and utilities where traceability and conformity matter. Feature: Sprinkler-proof plug-in features and ergonomic design. Impact: Improves safety margins and allows quicker service access in restricted spaces. Application: Critical in sprinkler-protected rooms and dense electrical closets where reliable protection is required.

Get a Quick Quote for a Eaton P3BFD3060NSP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BFD3060NSP? Enquire Now

FAQs

To install the P3BFD3060NSP, confirm compatibility with the Pow-R-Way III busway, ensure proper sizing for the 60A rating, and align grounding options with the facility's grounding scheme. Use the sprinkler-proof plug-in design to minimize moisture exposure during insertion, and verify 100% neutral configuration for balanced loads. Plan for a clean 12.36 inch depth and 5.43 inch width to fit the intended panel space, and follow Eaton’s mounting guidelines to streamline commissioning.
The 60A rating denotes the maximum continuous current the device is intended to carry, while the interrupt ratings (65 kAIC at 240V, 25 kAIC at 480V, 18 kAIC at 600V) define the maximum fault current the breaker can interrupt safely. This combination provides substantial protection for busways and feeders, reducing the risk of equipment damage during short circuits. Ensure system fault current levels are within these limits during protective device coordination studies.
Yes. The unit features a sprinkler-proof plug-in design that minimizes moisture ingress and corrosion risk, supporting reliable operation in environments with humidity or exposure to water sprays. This makes it well-suited for life-safety zones, industrial plants, and areas near cooling towers or wash-down stations where environmental conditions can challenge electrical protection devices.
The P3BFD3060NSP carries CSA Certified, IEEE Certified, UL 857, and ANSI certifications and is NEMA Compliant. These marks indicate adherence to recognized safety and performance standards, facilitating regulatory approvals in North America and helping ensure safe operation, proper interoperability, and smoother acceptance testing in regulated facilities.
Long-term maintenance is simplified by the plug-in design and sprinkler-proof construction, which reduces service time and exposure while preserving system uptime. The device’s high interrupt ratings provide protection against costly fault events, supporting a lower total cost of ownership. ROI is driven by faster panel upgrades, reduced downtime, and consistent compliance with evolving electrical codes.