Eaton P3BFD3200N Pow-R-Way III plug-in - UL 857
Part Number: P3BFD3200N
Quick Summary
Eaton P3BFD3200N Pow-R-Way III circuit breaker plug-in unit protects busway distributions in industrial facilities. It delivers reliable overcurrent protection for 240, 480, and 600 V systems with a 200 A rating, reducing the risk of damaging faults and unplanned downtime. The design supports rapid maintenance with high interrupt ratings of 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, and 18 kAIC at 600 Vac, while offering 100% Neutral and 50% Integral Ground options for safer, more dependable operation. Certified to NEMA standards and UL 857, with CSA, IEEE, and ANSI listings, this unit meets rigorous regulatory requirements. For buyers, the combination of plug-in convenience, robust protection, and compatibility with Busway translates to lower lifecycle costs and simpler spares management across facilities.
Product Information
Extended Description
P3BFD3200N Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, FD, Plug, Breaker, F Frame (15-225 A), 200A, 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac, 100% Neutral, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BFD3200N
UPC
786683007115
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
CSA Certified IEEE Certified UL 857 ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
200A
Interrupt rating
65 kAIC at 240 Vac, 25 kAIC at 480 Vac, 18 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Feature → Business Impact → Application: The P3BFD3200N is a three-pole Pow-R-Way III plug-in breaker rated at 200 A, delivering 65 kAIC at 240 V, 25 kAIC at 480 V, and 18 kAIC at 600 V, which translates to superior fault protection for sensitive motor loads and critical busway sections in manufacturing lines. This high interrupt capacity reduces arc-flash exposure and equipment damage, improving uptime in continuous processes and packaging lines. Application: Busway distribution in industrial facilities requiring reliable, scalable overcurrent protection and quick field replacements. Feature → Business Impact → Application: 100% Neutral with 50% Integral Ground provides a complete fault path, enhancing safety and simplifying grounding strategies for control panels and switchgear assemblies. Application: Electrical rooms and panelized power distribution where accurate grounding is essential for protection coordination and compliance. Feature → Business Impact → Application: Plug-in design enables fast removal and replacement, minimizing downtime during maintenance or when upgrading busway segments. Application: Field service scenarios where quick swaps are essential to maintain production targets. Feature → Business Impact → Application: NEMA compliant and UL 857 with CSA/IEEE/ANSI certifications ensure regulatory acceptance, simplifying audits and installation approvals. Application: New builds and retrofits in regulated industries like food & beverage, water treatment, and metals manufacturing. Feature → Business Impact → Application: Compact form factor and weight (12.36 in L, 21.2 in H, 5.43 in W, 25 lb) supports easier fit alongside existing busway infrastructure and reduces installation penalties. Application: Tight-space installations and retrofits in engineering facilities where space optimization matters. Feature → Business Impact → Application: One-year warranty (or 18 months from shipment) lowers total cost of ownership by reducing risk and providing long-term support for spare part planning. Application: Asset lifecycle planning and maintenance budgeting in large-scale automation deployments.
Get a Quick Quote for a Eaton P3BFD3200N
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BFD3200N?
Enquire Now
FAQs
To install, verify system de-energization, mount the plug-in unit in the designated busway slot, connect the three-pole inputs per the wiring diagram, attach the 100% Neutral and 50% integral/ housing grounding as specified, and secure all terminations. Ensure clearances and torque values meet manufacturer guidelines and confirm compliance with UL 857 and NEMA requirements during commissioning.
The device provides a 200 A amperage rating with interrupt ratings of 65 kAIC at 240 Vac, 25 kAIC at 480 Vac, and 18 kAIC at 600 Vac. It features 100% Neutral and 50% integral grounding, and is suitable for three-pole busway installations in industrial environments.
Yes. It carries UL 857 certification and is CSA and IEEE certified, with ANSI listings and NEMA compliance. These certifications support regulatory approvals, safety compliance, and interoperability within typical industrial control and power distribution systems.
The unit comes with a one-year warranty from the date of installation or eighteen months from shipment, whichever comes first. This ensures coverage for manufacturing defects and provides a basis for spare parts planning and support through Eaton's technical services.
The breaker measures 12.36 in in depth, 21.2 in in height, and 5.43 in in width, with an approximate weight of 25 lb. These dimensions fit standard busway enclosures and support straightforward integration into existing layouts without significant rework.