Eaton P3BFDC3200N Circuit Breaker Plug-in Unit - UL 857 Certified

Part Number: P3BFDC3200N
Manufacturer
Eaton
Part number
P3BFDC3200N

Quick Summary

The Eaton P3BFDC3200N circuit breaker plug-in unit provides reliable protection for Pow-R-Way III busway systems in industrial facilities. With common upgrade paths and tight install windows, it minimizes downtime during panel retrofits and reduces field wiring complexity. Certified to IEEE, CSA, ANSI, and UL 857 standards, it delivers trusted safety and regulatory alignment for critical operations. Operating as a 3-pole breaker in a Pow-R-Way III busway, it matches a 200A amperage rating with 100% neutral, optimized for scalable power distribution and easier maintenance. Engineered for NEMA compliance and rugged industrial environments, it supports fast replacements and predictable performance in harsh conditions.

Product Information

Extended Description

P3BFDC3200N Eaton: Pow-R-Way III Busway, Circuit Breaker Plug-in Unit, 3-Pole, 200 AMP, FDC Frame Type, 100% Neutral
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BFDC3200N
UPC
786683008471
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Compliances
NEMA Compliant
Certifications
IEEE Certified CSA Certified ANSI UL 857
Circuit Breaker Frame
F
Grounding Options
50% Integral/Housing
Type
Breaker
Amperage Rating
200A
Interrupt rating
200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 35 kAIC at 600 Vac
Neutral Options
100%
Feature: 3-pole, 200A amperage with a 200 kAIC at 240V interrupt rating; Business Impact: robust protection for high-demand loads, minimizes fault-related downtime; Application: Pow-R-Way III busway distribution in manufacturing lines. Feature → Business Impact → Application. Feature: 100% Neutral option; Business Impact: ensures balanced neutral currents and stable operation for sensitive equipment; Application: data processing and control panels within industrial facilities. Feature: 50% Integral grounding option; Business Impact: simplifies grounding schemes, reduces installation time and error; Application: plug-in unit installations in crowded electrical rooms. Feature: NEMA compliant with IEEE, CSA, ANSI, UL 857 certifications; Business Impact: regulatory alignment and safer procurement; Application: compliance-focused deployments across facilities. Feature: Compact footprint with 12.36 in depth, 21.2 in height, 5.43 in width, 25 lb weight; Business Impact: easier integration into existing busway racks and limited spaces; Application: retrofit projects and modular distribution updates.

Get a Quick Quote for a Eaton P3BFDC3200N

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BFDC3200N? Enquire Now

FAQs

Yes. The P3BFDC3200N is a 3-pole circuit breaker plug-in unit specifically designed for Pow-R-Way III busways, featuring a 200A rating and a 50% grounding option. It uses the FDC frame type and supports 100% neutral, ensuring seamless integration with existing busway installations and straightforward field replacements.
The unit provides a 200A amperage rating with interruption capabilities of 200 kAIC at 240V, 100 kAIC at 480V, and 35 kAIC at 600V. It is built as a 3-pole breaker with a 100% neutral option, suitable for high-demand industrial loads while maintaining safety margins in diverse switching scenarios.
Industries relying on modular Pow-R-Way III busways, such as manufacturing, process plants, and heavy equipment environments, benefit most. The 200A rating, high interrupt margins, and plug-in design enable rapid upgrades, reduced downtime, and scalable power distribution for critical loads in demanding industrial settings.
It carries IEEE and CSA certifications, along with ANSI and UL 857 compliance, and is NEMA compliant. These certifications support regulatory alignment, safety assurance, and reliable supplier qualification for industrial procurement programs.
Plan for a plug-in replacement in Pow-R-Way III busways with attention to grounding (50% integral), neutral connections, and frame compatibility (FDC). Regular inspections of neutral terminations and tightness, along with scheduled tests of interrupt performance, help minimize unplanned downtime and extend service life, delivering predictable maintenance costs and improved ROI.