Eaton P3BHFD3015SP Circuit Breaker Plug-in - Sprinkler-Proof

Part Number: P3BHFD3015SP
Manufacturer
Eaton
Part number
P3BHFD3015SP

Quick Summary

The Eaton P3BHFD3015SP circuit breaker plug-in unit provides reliable protection for busway systems in industrial power distribution. Engineers frequently face compatibility and space constraints during upgrades, leading to project delays and extra wiring costs. It carries IEEE certification, UL 857 listing, CSA certification, and ANSI compliance, reinforcing safety and regulatory alignment. As part of Eaton's Pow-R-Way III family, it enables quick plug-in installation and robust busway protection, reducing commissioning time and total cost of ownership. This combination translates to faster project turnover and safer startups in critical facilities, while maintaining regulator-ready documentation for audits and maintenance planning.

Product Information

Extended Description

P3BHFD3015SP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Sprinkler-proof plug-in, Busway, Three-pole, HFD, Breaker, F Frame (15-225 A), 15A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3015SP
UPC
786685243436
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
IEEE Certified UL 857 CSA Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
15A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Special features
Sprinkler-proof plug-in
Sprinkler-proof plug-in design minimizes risk and simplifies service in sprinkler-protected areas. The fast-connect plug-in format enables rapid changes without tools, minimizing outage time during maintenance or replacements. Application: busway installations in industrial facilities where safety and uptime are critical. Designed for Pow-R-Way III busway systems, the three-pole F-frame fits precisely, reducing field trimming and misalignment. This tight fit translates to fewer spare parts and quicker commissioning, especially in crowded electrical rooms. The unit’s high interrupt rating delivers dependable protection: 100 kAIC at 240 and 480 Vac, and 25 kAIC at 600 Vac, with a 15A amperage rating supporting balanced feeder runs while maintaining selectivity with downstream devices. Core dimensions and a 25 lb shipment weight support straightforward installation: 12.36 in deep, 5.43 in wide, 21.2 in tall. Grounding options provide flexible installation with 50% integral or housing grounding, reducing wiring complexity. Compliance and safety are reinforced by NEMA compliance and certifications (IEEE, UL 857, CSA, ANSI), backed by Eaton’s established support and documentation, simplifying audits and maintenance planning. Warranty coverage includes one year from installation or eighteen months from shipment, whichever occurs first, aiding long-term budgeting.

Get a Quick Quote for a Eaton P3BHFD3015SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3015SP? Enquire Now

FAQs

Install as a three-pole F-frame Pow-R-Way III plug-in unit within compatible busway enclosures. The device measures 12.36 in depth, 5.43 in width, and 21.2 in height, with a 25 lb weight, facilitating a straightforward drop-in replacement. Use the sprinkler-proof plug-in design to minimize downtime and ensure correct grounding (50% integral or housing). Verify 15A rating and 100 kAIC at 240/480 Vac, with 25 kAIC at 600 Vac, to match system protection needs.
The P3BHFD3015SP is rated at 15A with an interrupt rating of 100 kAIC at 240 Vac and 480 Vac, and 25 kAIC at 600 Vac. This combination supports reliable short-circuit protection for busway feeders, enabling selective coordination with downstream protective devices and reducing the risk of cascading failures in industrial environments.
Yes. The unit features a sprinkler-proof plug-in design, specifically intended for use in sprinkler-protected facilities. Its busway compatibility and robust ratings make it suitable for critical infrastructure where uptime and safety are paramount, such as manufacturing lines, data centers, and process facilities with stringent fire-suppression requirements.
This Eaton plug-in unit carries IEEE certification, UL 857 listing, CSA certification, and ANSI compliance, along with NEMA compliance. These certifications support safety, regulatory alignment, and ease audits across industrial installations, ensuring the device meets industry-best practices for electrical protection in heavy-duty environments.
The product is covered by Eaton's policy: one year from installation or eighteen months from shipment, whichever occurs first. Quick plug-in installation, minimal downtime, and proven reliability reduce commissioning time and maintenance costs, contributing to lower total cost of ownership and faster project ROI in busy facilities.