Eaton P3BHFD3030SP Circuit Breaker Unit - NEMA Compliant

Part Number: P3BHFD3030SP
Manufacturer
Eaton
Part number
P3BHFD3030SP

Quick Summary

The Eaton P3BHFD3030SP circuit breaker plug-in unit provides dependable overcurrent protection for three-pole busway systems in industrial facilities. Designers face challenges like sprinkler-proof assemblies, limited installation space, and the need to coordinate high interrupt ratings across multiple voltages without sacrificing accessibility. It carries UL 857, CSA, and IEEE certifications, with ANSI standards ensuring consistent performance, and it’s designed for NEMA-compliant applications where safety and reliability matter. Powered by the Pow-R-Way III platform, it offers a 30 A rating and sprinkler-proof plug-in features that cut installation time, reduce wiring complexity, and improve maintenance efficiency. Overall, the unit's grounding options, busway compatibility, and rugged housing deliver measurable business value through lower total cost of ownership and safer, more flexible protection.

Product Information

Extended Description

P3BHFD3030SP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Sprinkler-proof plug-in, Busway, Three-pole, HFD, Breaker, F Frame (15-225 A), 30A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3030SP
UPC
786685243146
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI CSA Certified IEEE Certified UL 857
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
30A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Special features
Sprinkler-proof plug-in
Sprinkler-proof plug-in design enhances safety in fire-suppression environments, reducing the risk of compromised protection during maintenance or reconfiguration and enabling faster retrofit projects in facilities with sprinkler systems. Business impact: improved uptime and reduced retrofit costs in manufacturing and processing plants; application: sprinkler-protected busway installations where quick, safe plug-in protection is needed. Pow-R-Way III architecture simplifies busway integration, delivering faster installation and fewer wiring connections, which translates to lower labor costs and quicker project turnover. Application: new builds and expansions in automotive, metal, and chemical processing facilities seeking scalable power distribution. The unit’s three-pole F-frame breaker rated at 30 A with 100 kAIC at 240/480 VAC and 25 kAIC at 600 VAC provides strong fault protection for high-demand equipment operating on multiple voltages. Application: machine trains and conveyors with diverse power requirements. Grounding options offer 50% integral or housing grounding, easing mounting in confined spaces and simplifying compliance with grounding practices. Application: compact switchgear enclosures and tight plant layouts where ground fault reliability matters. Certifications including UL 857, CSA, IEEE, and ANSI standards validate compliance across regulated markets, reducing procurement risk and speeding qualification. Application: purchasing for regulated facilities with strict certification requirements. Dimensions and weight enable precise space planning: 12.36 in depth, 21.2 in height, 5.43 in width, and 25 lb weight support straightforward mounting and enclosure compatibility. Application: retrofits and new installations where enclosure fit is critical.

Get a Quick Quote for a Eaton P3BHFD3030SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3030SP? Enquire Now

FAQs

The P3BHFD3030SP is designed for direct plug-in into Pow-R-Way III busway configurations. Verify pole count, frame type (F), and grounding option (50% integral/housing). Mount within compatible enclosures, connect to the busway run, and secure the unit per the manufacturer’s installation guidelines. The 12.36 in depth, 21.2 in height, and 5.43 in width fit standard busway footprints, reducing field tailoring and downtime.
This unit features a 30A amperage rating, with interrupt ratings of 100 kAIC at 240 VAC and 100 kAIC at 480 VAC, and 25 kAIC at 600 VAC. It is a three-pole, F-frame breaker designed for busway applications, delivering robust protection for multi-volt installations common in material handling, manufacturing, and processing facilities.
Yes. The P3BHFD3030SP includes sprinkler-proof plug-in capabilities, which simplifies safe operation in environments with fire suppression systems. This feature helps maintain protection integrity during maintenance or reconfiguration, reducing exposure to curtailment or downtime in sprinkler-equipped facilities.
The unit carries UL 857, CSA Certification, IEEE Certification, and ANSI compliance. These certifications support regulatory acceptance across North American markets and help streamline procurement for regulated facilities while confirming performance and safety standards.
Installation is accelerated by its plug-in busway design and compact footprint, reducing field wiring and labor costs. The high interrupt ratings improve protection for critical equipment, potentially lowering downtime costs; plus, the unit’s compliance and warranty support simplify maintenance planning and asset lifecycle management.