Eaton P3BHFD3060 circuit breaker plug-in unit - UL 857

Part Number: P3BHFD3060
Manufacturer
Eaton
Part number
P3BHFD3060

Quick Summary

Eaton Pow-R-Way III circuit breaker plug-in unit is a busway protection device designed for plug-in installation in industrial power distribution. Engineers often face downtime and complex retrofits when upgrading protection in modular busway systems, making quick, reliable integration essential. This unit carries UL 857, IEEE Certified, CSA Certified, and ANSI standards, with NEMA compliance supporting rugged field performance. For installers and procurement teams, the compact three-pole design, 60A rating, and 50% integral grounding translate into faster commissioning and lower total cost of ownership, while maintaining safety and regulatory compliance in demanding environments.

Product Information

Extended Description

P3BHFD3060 Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, HFD, Plug, Breaker, F Frame (15-225 A), 60A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3060
UPC
786683007498
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
UL 857 IEEE Certified CSA Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
60A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Feature: Three-pole F-frame, Pow-R-Way III design provides a compact, plug-in form factor that fits standard busway configurations. Business Impact: Reduces installation complexity and commissioning time, improving project timelines and minimizing field labor costs. Application: Ideal for modular busway systems in manufacturing plants and processing facilities. Feature: Amperage rating of 60A with high interrupt capability (100 kAIC at 240 Vac and 480 Vac, 25 kAIC at 600 Vac). Business Impact: Delivers robust fault protection for critical loads, reducing the risk of equipment damage and downtime. Application: Used for feeders and distribution legs in heavy industry. Feature: Grounding options at 50% integral/housing simplify grounding schemes and reduce external hardware. Business Impact: Streamlines safety compliance and lowers component count. Application: Suitable for new builds and upgrades in controlled environments. Feature: Compliance and certifications including UL 857, IEEE, CSA, ANSI, and NEMA compliance. Business Impact: Ensures regulatory acceptance across regions, easing procurement and maintenance planning. Application: Meets electrical code requirements for industrial power distribution. Feature: Physical dimensions and weight (12.36 in L, 21.2 in H, 5.43 in W, 25 lb) enable straightforward rack and enclosure fitting. Business Impact: Facilitates shipping, handling, and field installation with predictable clearances. Application: Compatible with standard electrical enclosures and busway interfaces. Feature: Warranty terms (1 year from installation or 18 months from shipment) provide post-sale protection. Business Impact: Reduces risk during commissioning and supports long-term maintenance planning. Application: Useful for asset management programs and service contracts.

Get a Quick Quote for a Eaton P3BHFD3060

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3060? Enquire Now

FAQs

The P3BHFD3060 is engineered as a three-pole plug-in unit within the Pow-R-Way III family, designed specifically for busway protection. It integrates with standard Pow-R-Way III interfaces, supports straightforward plug-in installation, and leverages the F-frame design for reliable mounting in compatible busway enclosures. This ensures fast field retrofit, minimized downtime, and predictable performance across modular distribution schemes.
Key ratings include a 60A amperage, 100 kAIC interrupt rating at 240 Vac and 480 Vac, and 25 kAIC at 600 Vac. It is a three-pole, F-frame breaker with 50% integral grounding. These specifications enable robust protection for busway feeders and allow operations to continue safely during faults, meeting industrial protection standards.
Yes, the unit is designed to meet stringent industry standards and is NEMA compliant, with UL 857, IEEE, CSA, and ANSI certifications backing its reliability. Its plug-in configuration minimizes field wiring errors and supports consistent protection in demanding environments such as manufacturing plants and processing facilities.
The P3BHFD3060 carries UL 857, IEEE Certified, CSA Certified, and ANSI certifications, with additional NEMA compliance. These certifications ensure electrical safety, performance reliability, and broad regulatory acceptance, which simplifies procurement, compliance audits, and maintenance planning.
Installation is streamlined by the plug-in design within the Pow-R-Way III platform, reducing commissioning time and field wiring complexity. The 60A rating with high interrupt capability protects critical loads, potentially lowering downtime and maintenance costs. With regulatory certifications in place and a clear warranty, the unit supports predictable lifecycle costs and faster return on investment.