Eaton P3BHFD3100SP circuit breaker plug-in unit - Sprinkler-proof

Part Number: P3BHFD3100SP
Manufacturer
Eaton
Part number
P3BHFD3100SP

Quick Summary

The Eaton Pow-R-Way III circuit breaker plug-in unit protects busway systems with reliable, plug-in protection. Engineers often struggle with sprinkler-protected environments and difficult wiring during power-distribution upgrades. It carries CSA, UL 857, IEEE and ANSI certifications, plus NEMA compliance for broader regulatory acceptance. Designed for busway protection, this 3-pole 100A F-frame breaker offers fast install and predictable maintenance, supporting reliability and cost efficiency. In practice, engineers see improved uptime, streamlined maintenance scheduling, and safer shutdowns in mixed voltage busway environments. By leveraging the unit's 100 kAIC ratings and sprinkler-proof design, you reduce downtime and extend service life, strengthening total cost of ownership.

Product Information

Extended Description

P3BHFD3100SP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Sprinkler-proof plug-in, Busway, Three-pole, HFD, Breaker, F Frame (15-225 A), 100A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3100SP
UPC
786685243207
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
CSA Certified UL 857 IEEE Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
100A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Special features
Sprinkler-proof plug-in
Feature: Sprinkler-proof plug-in design facilitates safe operation in environments with sprinkler systems. Business Impact: Increases system reliability and reduces risk during maintenance, leading to fewer unplanned outages. Application: Ideal for busway-based distributions in commercial, institutional, and light-industrial facilities, where sprinkler protection is a concern and downtime costs matter. Feature: Three-pole, F-frame construction with a 100A rating. Business Impact: Delivers robust current handling with standardized footprint, enabling straightforward retrofits and scalable protection. Application: Suitable for mid-range busway circuits and modular panels where space and reliability are critical.Feature: High interrupt ratings of 100 kAIC at 240 and 480 VAC, and 25 kAIC at 600 VAC. Business Impact: Provides generous fault-current margin, improving safety margins and reducing downstream damage during short circuits. Application: Fits sites with high short-circuit potential, such as data centers, manufacturing lines, and high-density equipment rooms.Feature: Grounding options of 50% integral or housing. Business Impact: Simplifies installation with flexible grounding paths, reducing wiring complexity and installation time. Application: Useful in mixed grounding schemes common in large facilities and retrofit projects.Feature: Compliance and certification package (NEMA compliant, CSA, UL 857, IEEE, ANSI). Business Impact: Eases procurement and commissioning within regulated environments, expediting approvals and audits. Application: Supports architecture and engineering standards compliance across diverse industries.Feature: Busway compatibility and sprinkler-proof plug-in design. Business Impact: Shortens installation cycles and minimizes downtime during upgrades, enabling faster project realization. Application: Particularly advantageous in retrofit projects targeting busway-based distributions with strict protection requirements.

Get a Quick Quote for a Eaton P3BHFD3100SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3100SP? Enquire Now

FAQs

P3BHFD3100SP is designed for seamless integration within Pow-R-Way III busway layouts. It features a sprinkler-proof plug-in design, 50% integral/housing grounding, and an F-frame three-pole enclosure. When installing, verify busway compatibility, ensure proper mounting clearances, and use the provided mounting hardware. This minimizes commissioning time and supports reliable, modular protection over the system lifecycle.
The unit provides a 100A amperage rating with a three-pole configuration. It offers interrupt ratings of 100 kAIC at 240 VAC and 480 VAC, and 25 kAIC at 600 VAC. It is suitable for busway distribution in facilities requiring high fault-current resilience, with compliance to NEMA, UL 857, and ANSI standards for safety and performance.
Yes. The sprinkler-proof plug-in design is specifically intended for environments where sprinklers are present. Benefits include enhanced enclosure integrity during fires or sprinkler discharge events, reduced risk of arc faults spreading, and safer maintenance under such conditions. This makes it a strong choice for commercial, institutional, and industrial spaces with stringent protection requirements.
The P3BHFD3100SP carries CSA Certified, UL 857, IEEE Certified, and ANSI certifications, along with NEMA compliance. These standards confirm reliability, electrical safety, and performance under regulatory scrutiny. They simplify procurement for regulated projects and support passing audits and commissioning for critical power distribution applications.
With a one-year warranty from installation or an 18-month window from shipment, maintenance planning is straightforward. The unit’s modular plug-in design reduces downtime during replacements, and its high interrupt ratings minimize downstream outages. Combined with reliable busway protection, this translates to lower maintenance costs and improved uptime, delivering a favorable total cost of ownership over the system lifecycle.