Eaton P3BHFD3110 Pow-R-Way III plug-in unit - IEEE/UL
Part Number: P3BHFD3110
Quick Summary
The Eaton Pow-R-Way III circuit breaker plug-in unit protects busway power distribution in industrial facilities. Engineers often grapple with bulky protection devices, challenging busway integration, and lengthy commissioning timelines; this plug-in unit streamlines installation and maintenance. Certifications include IEEE Certified, CSA Certified, ANSI, and UL 857 listings, all supported by NEMA compliance for rugged, field-ready performance. This solution leverages a compact form factor and robust ratings to deliver reliability, reduced downtime, and predictable lifecycle costs. By combining plug-in simplicity with high interrupt ratings, it supports scalable power protection while aligning with modern maintenance strategies and total-cost-of-ownership goals.
Product Information
Extended Description
P3BHFD3110 Eaton: Pow-R-Way III Busway, Circuit Breaker Plug-in Unit, 3-Pole, 110 AMP, HFD Frame Type
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3110
UPC
786683007696
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Compliances
NEMA Compliant
Certifications
IEEE Certified CSA Certified ANSI UL 857
Circuit Breaker Frame
F
Grounding Options
50% Integral/Housing
Type
Breaker
Amperage Rating
110A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Is a Pow-R-Way III circuit breaker plug-in unit designed for busway power distribution. Feature highlights include a 3-Pole design in the HFD frame, 110A amperage rating, and 100 kAIC interrupt ratings at 240/480 Vac, with reduced installation complexity and standardized maintenance. Business impact: installation time is shortened due to plug-in compatibility with Pow-R-Way busways, leading to lower labor costs and faster commissioning. Application: ideal for manufacturing lines and process areas requiring reliable fault protection in busway-fed distribution. Feature: 50% integral grounding option ensures effective fault paths, enhancing personnel safety and system uptime. Business impact: improved safety compliance and reduced grounding retrofit costs in retrofit projects. Application: retrofit projects in aging facilities benefit from seamless integration with existing busway infrastructure. Feature: NEMA compliance and multi-organization certifications (IEEE, CSA, ANSI, UL 857) provide regulatory assurance for global deployments, reducing risk in cross-border projects. Business impact: smoother procurement, lower risk of non-conformance, and enhanced customer confidence in maintenance planning. Application: utility-scale panels and OEM installations where standardized protection units simplify spare parts strategy. Feature: compact dimensions (12.36 in depth, 21.2 in height, 5.43 in width) and a 25 lb weight support straightforward mounting in limited spaces. Business impact: saves enclosure space, reduces shipping and handling costs, and enables flexible layout planning. Application: tight-control panels and switchgear rooms benefiting from space-efficient protection modules.
Get a Quick Quote for a Eaton P3BHFD3110
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BHFD3110?
Enquire Now
FAQs
The P3BHFD3110 is designed for Pow-R-Way III busway protection, with a 3-Pole configuration in the F frame. Installation benefits include plug-in mounting within compatible busways, compact depth (12.36 in) and overall form factor, and 25 lb weight for easier handling. The unit supports straightforward field wiring and quick replacement, reducing downtime during upgrades or maintenance.
Key specifications include a 110A amperage rating and a 100 kAIC interrupt rating at 240 Vac and 480 Vac (25 kAIC at 600 Vac). The product is intended for 3-Pole operation with NEMA compliance and UL 857, IEEE, CSA, and ANSI certifications, ensuring robust protection across standard industrial voltages.
Yes. It carries IEEE Certified, CSA Certified, ANSI, and UL 857 certifications and is NEMA compliant. These certifications support regulatory acceptance across industries and regions, enabling safer operation, easier audits, and smoother procurement for regulated environments.
The unit’s compact dimensions—12.36 in depth, 21.2 in height, and 5.43 in width—coupled with a 25 lb weight, enable installation in confined panel spaces and existing enclosures. Its plug-in design reduces wiring complexity and allows fast field replacement without extensive downtime.
By combining plug-in simplicity with high interrupt ratings and broad certifications, the P3BHFD3110 minimizes commissioning time, reduces spare parts variety, and lowers maintenance labor. Its reliability in busway systems translates to less unscheduled downtime and improved uptime metrics, delivering measurable ROI over the system life cycle.