Eaton P3BHFD3150SP Circuit Breaker Plug-in - NEMA Compliant

Part Number: P3BHFD3150SP
Manufacturer
Eaton
Part number
P3BHFD3150SP

Quick Summary

The Eaton Pow-R-Way III circuit breaker plug-in unit is designed to deliver reliable overcurrent protection for sprinkler-proof busway installations. Contractors and engineers often face the challenge of matching plug-in modules to dense layouts while preserving safety, reliability, and installation efficiency. This device carries UL 857, ANSI, CSA, and IEEE certifications, underscoring regulatory compliance and cross-panel interoperability. Its three-pole, 150 A frame with 100 kAIC at 240/480 Vac (and 25 kAIC at 600 Vac) supports scalable protection without complicating field wiring. With a sprinkler-proof plug-in design and 50% integral/housing grounding options, it simplifies installation and reduces downtime in commercial and industrial power distribution networks.

Product Information

Extended Description

P3BHFD3150SP Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Sprinkler-proof plug-in, Busway, Three-pole, HFD, Breaker, F Frame (15-225 A), 150A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3150SP
UPC
786685243221
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI CSA Certified IEEE Certified UL 857
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
150A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Special features
Sprinkler-proof plug-in
Feature: Sprinkler-proof plug-in design provides robust protection in sprinklered environments. Business Impact: Enhances safety margins while reducing field routing complexity and potential wiring errors. Application: Ideal for sprinkler-protected busway feeders in warehouses, data centers, and manufacturing floors, where quick, reliable plug-in protection minimizes commissioning time. Feature: High interrupt ratings deliver strong fault current control. Business Impact: Limits equipment damage and system downtime during short-circuit events, improving overall availability. Application: Suitable for 100 kAIC fault scenarios at 240/480 VAC, with continued protection at 600 VAC. Feature: Grounding options offer flexible installation. Business Impact: Cuts wiring and testing time while improving fault path reliability. Application: 50% integral/housing grounding supports adaptable integration into diverse busway configurations. Feature: Busway compatibility and modular design enable faster deployment. Business Impact: Reduces installation labor and panel footprint, accelerating project timelines. Application: Three-pole, 150 A Pow-R-Way III modules scale with growing power distribution needs. Feature: Regulatory certifications and robust construction mitigate compliance risk. Business Impact: Simplifies approval processes and contractor acceptance. Application: UL 857, ANSI, CSA, IEEE certified, NEMA compliant housing ensure field readiness and cross-site interoperability.

Get a Quick Quote for a Eaton P3BHFD3150SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3150SP? Enquire Now

FAQs

The P3BHFD3150SP is a three-pole, 150 A circuit breaker plug-in unit designed for sprinkler-proof busway installations. It integrates with Pow-R-Way III modules and busway feeders, enabling modular protection in dense panel layouts. Its NEMA compliance and UL/ANSI/CSA/IEEE certifications support seamless integration in commercial and industrial power distribution environments.
The unit offers a 150 A amperage rating with interrupt ratings of 100 kAIC at 240 VAC and 480 VAC, plus 25 kAIC at 600 VAC. This combination supports high fault current scenarios typical in industrial facilities while maintaining short-circuit response times and protecting downstream equipment and wiring.
Yes. The unit is specifically designed as a sprinkler-proof plug-in for busway systems, with a 50% integral/housing grounding option that simplifies grounding. Its modular three-pole, F-frame design reduces field wiring and allows rapid swap-ins or upgrades, improving project timelines and reliability in distributed power networks.
The P3BHFD3150SP carries UL 857 certification along with ANSI and CSA certifications, and IEEE compatibility. These certifications confirm regulatory compliance, interoperability across control panels, and assurance that the device meets performance and safety standards required in regulated industries.
Plan for sprinkler-proof installation, busway clearance, and grounding routing given the 50% integral grounding option. The unit’s 12.36 in depth, 21.2 in height, and 5.43 in width define a compact footprint, while its 25 lb weight supports straightforward handling during maintenance. The protection level and modularity contribute to reduced downtime and long-term ROI.