Eaton P3BHFD3200 Pow-R-Way III circuit breaker plug-in unit - UL 857

Part Number: P3BHFD3200
Manufacturer
Eaton
Part number
P3BHFD3200

Quick Summary

The Eaton P3BHFD3200 Pow-R-Way III circuit breaker plug-in unit protects busway feeders in industrial electrical distributions. Maintaining reliable breaker coordination and quick replacement in crowded switchgear is a common challenge for operators and maintenance teams. This unit carries UL 857, CSA Certified, IEEE Certified, and ANSI alignment, ensuring safety, reliability, and cross‑vendor compatibility in critical power systems. Designed for power management & distribution applications, it supports fast plug‑in installation, scalable busway protection, and reduced lifecycle costs.

Product Information

Extended Description

P3BHFD3200 Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, HFD, Plug, Breaker, F Frame (15-225 A), 200A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3200
UPC
786683007856
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
UL 857 CSA Certified IEEE Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
200A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Three-pole, F-frame construction delivers a 200A amperage rating for dependable protection of busway feeders. This improves fault handling and breaker coordination, reducing unplanned outages in manufacturing and distribution facilities. It's well suited for Eaton Pow-R-Way III busway installations where quick plug-in integration is required. High interrupt ratings—100 kAIC at 240/480 Vac and 25 kAIC at 600 Vac—provide reliable fault interruption under diverse supply conditions. This reduces equipment damage and improves safety margins in facilities with high short-circuit currents. Ideal for three-pole plug-in protection within busway systems in data centers and manufacturing lines. Grounding options offer 50% integral or housing ground, simplifying field wiring and grounding planning. This flexibility lowers labor costs during installation and minimizes miswiring risk. It's especially beneficial in retrofits or modular busway expansions where space is at a premium. UL 857, CSA Certified, IEEE Certified, and ANSI alignment provide broad regulatory assurance and cross-vendor compatibility. This simplifies procurement, reduces approval cycles, and supports audit-ready documentation across facilities in regulated industries. Compact footprint with dimensions of 12.36 in length, 21.2 in height, and 5.43 in width, weighing 25 lb, enables integration into existing panels and busway enclosures. The plug-in design supports fast maintenance and straightforward replacement, minimizing downtime during service and spares stocking. Warranty policy offers one year from installation or 18 months from shipment, whichever occurs first, ensuring coverage during initial commissioning.

Get a Quick Quote for a Eaton P3BHFD3200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3200? Enquire Now

FAQs

Yes. The P3BHFD3200 is a three-pole plug‑in unit designed for Pow-R-Way III busway installations. It uses the F-frame design and a 200A rating to align with typical Eaton busway configurations, ensuring straightforward mounting, wiring, and compatibility with standard catalog components in new builds or retrofit projects.
The unit provides 100 kAIC interrupt rating at 240 Vac and 480 Vac, and 25 kAIC at 600 Vac. These ratings support effective short‑circuit interruption across common industrial power networks, reducing equipment damage and improving safety during fault events.
Yes. With a 200A rating and high interrupt capabilities, the P3BHFD3200 is well suited for busway feeders in data centers and heavy manufacturing environments. Its plug‑in design facilitates rapid deployment and maintenance, while grounding options and certifications support critical infrastructure requirements.
This unit carries UL 857 certification, CSA certification, IEEE alignment, and ANSI standards. These certifications support regulatory compliance, cross‑vendor interoperability, and easier procurement for facilities operating under strict electrical codes.
Warranty covers one year from installation or 18 months from shipment, whichever occurs first. The plug‑in design minimizes downtime during maintenance, simplifies spares management, and reduces labor costs during retrofit projects, contributing to lower total cost of ownership over the system lifecycle.