Eaton P3BHFD3200GN Circuit Breaker Plug-In Unit - IEEE/UL
Part Number: P3BHFD3200GN
Quick Summary
Eaton Pow-R-Way III circuit breaker plug-in unit provides reliable fault protection for busway assemblies in industrial power distribution. When space is tight and system loads are rising, configuring plug-in protection can become complex, risking downtime and miswiring. This Eaton unit is IEEE Certified, UL 857 listed, and CSA/ANSI certified, signaling compliance and interoperability across regions. Designed for fast, safe plug-in installation on Pow-R-Way III busway, it helps engineering teams shorten commissioning, reduce spare parts, and lower lifecycle costs. With a 200A rating, high interrupt ratings, 100% Neutral, and 50% Internal Ground, it delivers robust protection while simplifying maintenance in power management and distribution environments.
Product Information
Extended Description
P3BHFD3200GN Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, HFD, Plug, Breaker, F Frame (15-225 A), 200A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, 100% Neutral, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3200GN
UPC
786683007887
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
IEEE Certified UL 857 ANSI CSA Certified
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Internal
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
200A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Three-pole, F-frame plug-in unit designed for Pow-R-Way III busway systems delivers a compact, easy-to-install protection module that reduces panel space requirements and accelerates commissioning. The 200A amperage rating paired with 100 kAIC at 240/480 Vac (and 25 kAIC at 600 Vac) provides robust fault tolerance, minimizing unplanned downtime in manufacturing lines and data centers. A 100% Neutral and 50% Internal Ground configuration ensures reliable neutral integrity and grounded fault paths, improving protection for sensitive loads. NEMA compliance plus IEEE, UL 857, ANSI and CSA certifications support regional regulatory conformity, enabling faster approval cycles and lower risk in multi-region projects. Dimensions of 12.36 in length, 21.2 in height, and 5.43 in width simplify space planning, while the 25 lb weight supports straightforward on-site handling and replacements. The unit ships with a one-year warranty from installation, or 18 months from shipment, whichever comes first, reinforcing supplier confidence and lifecycle planning for busway architectures.
Get a Quick Quote for a Eaton P3BHFD3200GN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BHFD3200GN?
Enquire Now
FAQs
The P3BHFD3200GN is a plug-in three-pole unit designed specifically for Eaton Pow-R-Way III busway platforms. It fits the F-frame breaker design, supports 200A service, and integrates with standard busway panels. This compatibility minimizes field wiring changes, reduces installation time, and simplifies spare parts management for new builds or upgrades.
Key ratings include 200A amperage and interrupt ratings of 100 kAIC at 240/480 Vac and 25 kAIC at 600 Vac. Certifications include IEEE Certified, UL 857, ANSI, and CSA Certified, with NEMA compliance. These credentials help ensure regulatory acceptance across regions and provide confidence in safe operation within industrial power distribution systems.
The plug-in design enables rapid field replacement of a single protective module without disassembling the entire switchgear, reducing downtime. Field-replaceable components, a clear warranty window (one year from installation or 18 months from shipment), and standardized busway interfaces combine to lower maintenance costs, improve uptime, and simplify inventory planning for spare parts.
Yes. The combination of a three-pole 200A breaker, high interrupt ratings, 100% Neutral, and 50% Internal Ground provides robust fault protection and reliable pathing for critical loads. Its fast plug-in installation and established certifications support consistent performance in high-demand environments like automation, packaging, and continuous-process facilities.
Plan for a Pow-R-Way III busway installation with a three-pole F-frame breaker. The unit measures 12.36 in long, 21.2 in high, and 5.43 in wide, weighing 25 lb. Ensure proper clearance for wiring access, space for neutral connection, and alignment with busway standoff mounting. Verify grounding requirements (50% Internal Ground) and maintain compliance with NEMA and regional codes.