Eaton P3BHFD3225 Circuit Breaker Plug-In Unit - UL 857

Part Number: P3BHFD3225
Manufacturer
Eaton
Part number
P3BHFD3225

Quick Summary

P3BHFD3225 Eaton Pow-R-Way III circuit breaker plug-in unit provides high-current protection for busway feeders. Engineers wrestling with lengthy commissioning and retrofit risk will value its quick plug-in design and robust fault tolerance. UL 857, IEEE Certified, and CSA Certified ensure safety, interoperability, and regulatory alignment, while ANSI compliance supports broader industrial standards. As a 225 A solution with 100 kAIC ratings, it delivers reliable protection and predictable performance, helping data centers and manufacturing facilities reduce downtime and optimize maintenance costs. In short, this plug-in unit combines trusted Eaton engineering with scalable protection for modern power distribution.

Product Information

Extended Description

P3BHFD3225 Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, HFD, Plug, Breaker, F Frame (15-225 A), 225A, 100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFD3225
UPC
786683007894
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
UL 857 IEEE Certified CSA Certified ANSI
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
225 A
Interrupt rating
100 kAIC at 240 Vac, 100 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Feature: Three-pole plug-in unit rated at 225 A with interrupt ratings of 100 kAIC at 240 Vac and 100 kAIC at 480 Vac, plus 25 kAIC at 600 Vac. Business Impact: Delivers robust fault current handling for busway feeders, reducing risk of cascading outages and enabling safer, more reliable equipment protection in critical lines. Application: Suitable for industrial distribution panels and data-center busway systems that demand high fault withstand and quick, plug-in replacement. Feature: Pow-R-Way III plug-in design with F-frame compatibility. Business Impact: Speeds installation and commissioning, minimizes field wiring errors, and lowers total cost of ownership through faster maintenance cycles. Application: Warehouse, manufacturing floor, and high-density electrical rooms requiring modular protection solutions. Feature: Grounding options showing 50% integral/housing grounding. Business Impact: Improves fault path reliability and safety, simplifying compliance with grounding practices in busway installations. Application: Large-scale power distribution where reliable grounding reduces arc-flash exposure and improves operator safety. Feature: Comprehensive compliance suite (UL 857, IEEE, CSA, ANSI). Business Impact: Ensures regulatory conformity and broad interoperability with other equipment, reducing procurement and integration risk. Application: Any industrial facility needing certified protection components within a UL 857 framework. Feature: Physical footprint and weight (12.36 in L, 21.2 in H, 5.43 in W, 25 lb). Business Impact: Predictable enclosure fitment and ease of handling during retrofit or expansion, enabling clean installation in constrained spaces. Application: Retrofit projects, panel upgrades, and modular busway expansions.

Get a Quick Quote for a Eaton P3BHFD3225

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFD3225? Enquire Now

FAQs

P3BHFD3225 uses the Pow-R-Way III plug-in design with an F-frame configuration, engineered for Eaton busway contexts. Ensure three-pole, 225 A listing matches your busway feeder rating, and follow UL 857 installation guidelines. The unit’s 12.36 in length, 21.2 in height, and 5.43 in width help confirm enclosure fit and spacing.
The unit is rated for 225 A with interrupt ratings of 100 kAIC at 240 Vac and 100 kAIC at 480 Vac, plus 25 kAIC at 600 Vac. These levels provide strong fault current protection for busway feeders in demanding industrial environments.
Yes. The product carries UL 857 certification with IEEE, CSA, and ANSI certifications, ensuring electrical safety, interoperability, and regulatory compliance across typical industrial applications.
P3BHFD3225 measures 12.36 in in length, 21.2 in in height, and 5.43 in in width, with a shipping weight of approximately 25 lb. These metrics support accurate layout, clearance, and handling during retrofits or upgrades.
The unit supports 50% integral or housing grounding, giving flexibility for ground fault paths in busway configurations and helping meet site-specific safety and grounding practices.