Eaton P3BHFWF3040GN Pow-R-Way III Plug-in - 100 kAIC

Part Number: P3BHFWF3040GN
Manufacturer
Eaton
Part number
P3BHFWF3040GN

Quick Summary

Eaton Pow-R-Way III circuit breaker plug-in unit protects busway systems with reliable, modular protection for industrial distribution. Engineers routinely struggle with limited space, wiring complexity, and the need to meet strict short-circuit ratings as plants evolve. This unit carries NEMA compliance along with ANSI UL 857, CSA Certification, and IEEE Certification, ensuring regulatory alignment across projects. Its plug-in design and 40A rating deliver fast installation, scalable protection, and lower lifecycle costs for power distribution networks. With 100% neutral and 50% internal grounding, it supports safe neutral distribution and grounding strategy within busway assemblies.

Product Information

Extended Description

P3BHFWF3040GN Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, HFWF, Plug, Breaker, F Frame (15-225 A), 40A, 100 kAIC 220-240, 70 kAIC at 380-415 Vac, 14 kAIC at 660-690 Vac, 100% Neutral, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BHFWF3040GN
UPC
782116629183
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI UL 857 CSA Certified IEEE Certified
Circuit Breaker Frame
F
Design
Pow-R-Way III
Grounding Options
50% Internal
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
40A
Interrupt rating
100 kAIC 220-240, 70 kAIC at 380-415 Vac, 14 kAIC at 660-690 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
The unit employs a three-pole, F-frame breaker optimized for plug-in busway modules. This topology delivers balanced protection and a compact footprint, helping you fit protection right where power enters a bank of busways. It’s designed for seamless integration with Eaton's Pow-R-Way III family, reducing installation steps and replacement time on the line. High interrupt ratings provide robust fault-current handling—100 kAIC at 220-240V, 70 kAIC at 380-415V, and 14 kAIC at 660-690V—minimizing the need for oversizing and enhancing system safety in motor and high-load busway applications. Neutral distribution is 100% with 50% internal grounding, improving fault management and personnel safety. The device meets NEMA compliance and ANSI UL 857, CSA, and IEEE certifications, supporting compliance-driven projects and procurement. Its footprint and plug-in design simplify retrofit and expansion, reducing downtime and lifecycle costs in evolving facilities. Designed for compatibility with the Pow-R-Way III family, it offers straightforward maintenance, rapid part replacement, and predictable performance in harsh industrial environments.

Get a Quick Quote for a Eaton P3BHFWF3040GN

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BHFWF3040GN? Enquire Now

FAQs

Yes. The P3BHFWF3040GN is a three-pole, F-frame plug-in circuit breaker designed specifically for Pow-R-Way III busway configurations. It integrates with the Pow-R-Way III family to enable rapid installation, straightforward replacements, and scalable protection across busway sections. Verify catalog alignment (P3BHFWF3040GN) and busway section compatibility before pairing with existing equipment.
The 100 kAIC rating at 220-240V indicates the maximum fault current this breaker can interrupt safely at that voltage range. This rating helps protect downstream equipment in medium- to high-current busway circuits, reducing the risk of damage during short-circuit events and allowing for a more compact protective solution without oversizing.
This unit is NEMA compliant and carries ANSI UL 857, CSA Certified, and IEEE Certified markings. These certifications ensure compliance with North American electrical codes and industry best practices, facilitating procurement, qualification testing, and regulatory acceptance in commercial and industrial installations.
The device measures 12.36 in in depth, 21.2 in in height, and 5.43 in in width, with a shipping weight around 25 lb. These dimensions support planning in crowded electrical rooms or panel banks and help ensure compatible packaging within busway assemblies and adjacent components.
Using this plug-in unit reduces installation time through a plug-in design, lowers wiring complexity, and enables modular protection upgrades as the plant expands. The 40A rating with 100% neutral and 50% internal grounding supports safer, scalable power distribution, while high interrupt ratings improve protection reliability and reduce total cost of ownership over the system lifecycle.