Eaton P3BKD3100 Pow-R-Way III Plug-In Unit - UL 857

Part Number: P3BKD3100
Manufacturer
Eaton
Part number
P3BKD3100

Quick Summary

The Eaton P3BKD3100 Pow-R-Way III circuit breaker plug-in unit protects busway installations by interrupting faults in three-pole configurations. Engineers often struggle with compatibility and maintenance when sourcing plug-in breakers for busway systems. This unit carries IEEE Certified, CSA Certified, ANSI, and UL 857 marks, with NEMA compliance for broad regulatory alignment. In practice, it supports reliable power distribution, simplifies preventive maintenance, and reduces downtime, delivering tangible value for manufacturers and integrators managing complex electrical distributions.

Product Information

Extended Description

P3BKD3100 Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, KD, Plug, Breaker, K Frame (70-400 A), 100A, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac, None, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKD3100
UPC
786683000475
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
IEEE Certified ANSI CSA Certified UL 857
Circuit Breaker Frame
K
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
100A
Interrupt rating
65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Feature: Three-pole KD plug-in breaker in Pow-R-Way III design → Business Impact: Robust protection for busway main lines and motor circuits → Application: Industrial facilities requiring dependable three-pole protection and quick plug-in replacement. Feature: 100A amperage rating with high interrupt capability (65 kAIC at 240V, 35 kAIC at 480V, 25 kAIC at 600V) → Business Impact: Superior fault current handling reduces arc-flash exposure and protects downstream equipment → Application: High-current busway installations and critical loads. Feature: 50% integral/housing grounding → Business Impact: Safer, code-compliant grounding path with simplified installation → Application: Ground-sensitive environments and modular distribution systems. Feature: Compliance suite (IEEE, CSA, ANSI, UL 857, NEMA) → Business Impact: Streamlined regulatory approvals and risk mitigation → Application: Regulated manufacturing and data-center environments. Feature: Compact dimensions (13.29 in L, 7.79 in W, 34.41 in H) and 53 lb weight → Business Impact: Easier retrofits, forklift-friendly shipping, and space-conscious layouts → Application: Retrofit projects and tight machinery rooms. Feature: 25-000 warranty terms (1 year from install or 18 months from shipment) → Business Impact: Clear warranty coverage reduces lifecycle risk and total cost of ownership → Application: Procurement planning and long-term maintenance strategies.

Get a Quick Quote for a Eaton P3BKD3100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BKD3100? Enquire Now

FAQs

When installing the P3BKD3100, ensure compatibility with three-pole busway configurations and KD frame fit. Verify mounting clearance, confirm grounding path (50% integral/housing), and follow Eaton's wiring diagrams to avoid percussive faults. The plug-in design supports quick replacement during maintenance windows, minimizing downtime.
The unit is rated at 100A with interrupt ratings of 65 kAIC at 240V, 35 kAIC at 480V, and 25 kAIC at 600V. This makes it suitable for high fault-current environments and motor-heavy processes. Use these ratings to calculate upstream protection coordination and ensure busway sections stay within safe thermal limits.
Yes. Designed for busway systems with three-pole breakers, it delivers dependable protection for main and feeder circuits. Its grounding option, frame compatibility (K frame), and plug-in convenience support scalable protection schemes in manufacturing, data centers, and process facilities where modular distribution is critical.
The P3BKD3100 carries IEEE Certified, CSA Certified, ANSI, and UL 857 certifications, along with NEMA compliance. These marks demonstrate safety, interoperability, and regulatory alignment, reducing risk during audits and helping procurement meet stringent industry standards for industrial power distribution.
The plug-in design minimizes maintenance downtime by enabling rapid replacement without extensive rewiring. With a defined warranty window (one year from install or 18 months from shipment) and robust fault ratings, facilities can lower total cost of ownership through predictable service intervals, fewer cabinet removals, and improved uptime metrics.