Eaton P3BKD3200GN Pow-R-Way III circuit breaker - 65 kAIC

Part Number: P3BKD3200GN
Manufacturer
Eaton
Part number
P3BKD3200GN

Quick Summary

Eaton Pow-R-Way III circuit breaker plug-in unit protects busway systems with a reliable 200A three-pole design. This solution addresses common installation challenges in crowded electrical rooms by delivering a plug-in, KD-compatible option that reduces field wiring and downtime. ANSI IEEE Certified, CSA Certified, and UL 857 listed, the unit aligns with strict industry standards while supporting 100% neutral and 50% internal grounding. For engineers and procurement teams, it offers predictable performance, straightforward replacement, and optimized total cost of ownership in mid to large-scale power-distribution layouts.

Product Information

Extended Description

P3BKD3200GN Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, KD, Plug, Breaker, K Frame (70-400 A), 200A, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac, 100% Neutral, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKD3200GN
UPC
786683000666
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI IEEE Certified CSA Certified UL 857
Circuit Breaker Frame
K
Design
Pow-R-Way III
Grounding Options
50% Internal
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
200A
Interrupt rating
65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Feature → Business Impact → Application: Three-pole, KD plug-in unit with K-frame design enables quick installation and space optimization in busway configurations, reducing commissioning time and field labor. Application: Perfect for 200A busway feeders where compact, modular protection is required. Feature → Business Impact → Application: 65 kAIC at 240V, 35 kAIC at 480V, and 25 kAIC at 600V provide scalable protection across voltage tiers, minimizing fault energy and equipment damage. Application: Critical feeders in manufacturing lines and data-center margins. Feature → Business Impact → Application: 100% Neutral and 50% Internal Ground options simplify grounding schemes and neutral management, improving fault detection and system reliability. Application: Suitable for complex electrical rooms with strict grounding practices. Feature → Business Impact → Application: Cover dimensions and weight (13.29 in L, 34.41 in H, 7.79 in W, 53 lb) support predictable rack and busway compatibility. Application: Space-constrained installations requiring precise footprint. Feature → Business Impact → Application: NEMA Compliant and UL 857, ANSI IEEE Certified, CSA Certified assurance reduces compliance risk and eases project approvals. Application: Regulatory-driven deployments in diverse markets. Feature → Business Impact → Application: Plug-in, three-pole breaker with KD design reduces spare parts inventory and improves maintenance turnaround times. Application: Operations teams seeking lower maintenance windows and faster replacements.

Get a Quick Quote for a Eaton P3BKD3200GN

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BKD3200GN? Enquire Now

FAQs

The P3BKD3200GN is a three-pole KD plug-in unit designed for KD busway configurations with a K-frame. Ensure proper alignment with the busway, secure mounting, and confirm 100% neutral and 50% internal grounding as specified. Verify compliance with NEMA, UL 857, and ANSI/IEEE standards during installation to ensure safe operation and easy future replacement.
The unit provides 65 kAIC at 240V, 35 kAIC at 480V, and 25 kAIC at 600V. These ratings support robust fault protection for mid-range to higher-energy feeders in industrial facilities, reducing fault energy transfer and protecting downstream equipment.
Yes. The P3BKD3200GN carries UL 857 certification, along with ANSI/IEEE and CSA certifications, and is NEMA compliant. These certifications help ensure regulatory compliance, safer operation, and easier project approvals across North American facilities.
Plan for a footprint of 13.29 in (length) × 34.41 in (height) × 7.79 in (width) with an approximate weight of 53 lb. This helps with rack or enclosure sizing, cable routing, and maintenance accessibility in space-constrained electrical rooms.
The plug-in design streamlines replacement and reduces field labor, while the high interrupt ratings and busway compatibility minimize downtime during faults. Combined with strong certifications and grounding options, this translates to lower maintenance costs, faster service, and improved system reliability over the product life cycle.