Eaton P3BKD3250N Pow-R-Way III circuit breaker plug-in unit - 65 kAIC

Part Number: P3BKD3250N
Manufacturer
Eaton
Part number
P3BKD3250N

Quick Summary

The Eaton P3BKD3250N Pow-R-Way III circuit breaker plug-in unit provides reliable fault protection for busway power distribution systems. This plug-in solution helps maintain service by enabling quick maintenance with minimal downtime during replacements. Engineers often face space constraints and complex wiring in high-density environments; this unit supports fast plug-in installation for safe isolation and accelerated commissioning. It carries CSA, IEEE, UL 857, ANSI, and NEMA compliance, ensuring broad regulatory acceptance across facilities. With a 250 A rating and 65 kAIC interrupt at 240 Vac (35 kAIC at 480 Vac, 25 kAIC at 600 Vac), plus 100% Neutral and 50% integral grounding, it delivers scalable, code-compliant protection for busway applications while aligning with maintenance budgets and lifecycle costs.

Product Information

Extended Description

P3BKD3250N Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, KD, Plug, Breaker, K Frame (70-400 A), 250A, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac, 100% Neutral, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKD3250N
UPC
786683000734
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
CSA Certified IEEE Certified UL 857 ANSI
Circuit Breaker Frame
K
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
250 A
Interrupt rating
65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Feature: Plug-in Pow-R-Way III design enables rapid field upgrades with minimal wiring. This reduces downtime and labor costs during routine maintenance or expansion. It is ideal for busway feeder sections in large industrial plants. | Feature: Three-pole, 250 A frame with 65 kAIC at 240 Vac provides robust short-circuit protection. This level of interrupt rating safeguards equipment, protects personnel, and minimizes collateral damage during faults. The design supports high-demand loads common in motor control centers and conveyor systems feeding busway networks. | Feature: Neutral and grounding options include 100% Neutral and 50% Integral/Housing Grounding. This configuration supports reliable return paths and flexible grounding schemes to meet diverse electrical codes. For engineers, it reduces design trade-offs when distributing neutral currents across multi-branch busways. In practice, it translates to safer startup sequences and better fault clearance reliability in demanding environments. | Feature: Compliance and certifications cover NEMA, CSA, IEEE, UL 857, and ANSI. This ensures the product meets widely adopted North American standards, easing procurement across multi-site operations and simplifying supplier qualification. It also supports regulatory inspections and helps sustain warranty coverage by demonstrating adherence to recognized safety and performance benchmarks. | Feature: Clear physical footprint and mounting flexibility with dimensions of 34.41 in height, 7.79 in width, 13.29 in depth and a nominal 53 lb weight. These metrics help planners allocate rack space, schedule shipping, and fit the unit into existing busway housings. The unit carries a one-year warranty from installation or 18 months from shipment, providing a predictable lifecycle and cost of ownership.

Get a Quick Quote for a Eaton P3BKD3250N

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BKD3250N? Enquire Now

FAQs

The P3BKD3250N is designed for busway feeder installations in industrial settings. It is a three-pole, plug-in circuit breaker that supports rapid replacement and modular power distribution, fitting standard busway housings and KD plug configurations. Ideal for manufacturing lines, material handling facilities, and data-center feeder sections seeking scalable, reliable protection with minimal downtime.
A 65 kAIC interrupt rating at 240 Vac enables safe interruption of high fault currents, reducing equipment damage and fire risk. This rating is crucial for mid-to-large motor loads and high inrush scenarios typical in busway networks. It also aligns with IEEE and UL standards, supporting high-reliability electrical systems in industrial environments.
Yes. The P3BKD3250N offers 100% neutral and 50% integral or housing grounding, allowing flexible neutral distribution and adaptable grounding schemes to meet diverse codes. This configuration simplifies wiring, supports compliant grounding layouts, and enhances fault clearance reliability in dense busway installations.
It carries CSA Certified, IEEE Certified, UL 857, ANSI, and is NEMA compliant. This ensures broad regulatory acceptance across North American facilities, simplifies supplier qualification, and reduces compliance risk during audits and cross-site procurement in multi-site operations.
Maintenance is minimized by the plug-in design, enabling quick replacements and testing with minimal downtime. The unit carries a one-year warranty from installation or eighteen months from shipment, giving a predictable lifecycle. For total cost of ownership, rely on its robust interrupt ratings and compatibility with standard busway housings to minimize spare parts and downtime.