Eaton P3BKDC3125N Circuit Breaker Plug-in Unit - 200 kAIC

Part Number: P3BKDC3125N
Manufacturer
Eaton
Part number
P3BKDC3125N

Quick Summary

The Eaton P3BKDC3125N circuit breaker plug-in unit provides plug-in overcurrent protection for busway power distribution. Maintenance downtime and compatibility with modern busway systems are common project bottlenecks. This unit carries ANSI and CSA certifications, IEEE listing, UL 857, and NEMA compliance to support safe, reliable operation. Optimized for Pow-R-Way III busway installations, this three-pole K-frame unit helps you meet a 125A rating with high interrupt ratings while delivering 100% neutral and 50% integral or housing grounding. By aligning with these standards, you gain safer, faster installs, reduced maintenance costs, and improved uptime for critical industrial facilities.

Product Information

Extended Description

P3BKDC3125N Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, KDC, Plug, Breaker, K Frame (70-400 A), 125A, 200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 50 kAIC at 600 Vac, 100% Neutral, 50% Integral or Housing Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKDC3125N
UPC
786683001335
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
ANSI CSA Certified IEEE Certified UL 857
Circuit Breaker Frame
K
Design
Pow-R-Way III
Grounding Options
50% Integral/Housing
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
125A
Interrupt rating
200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 50 kAIC at 600 Vac
Neutral Options
100%
Application
Busway
Product Category
Plug
Pow-R-Way III busway integration with a three-pole, K-frame design improves standardization and reduces commissioning time for busway-distribution in manufacturing and warehouses. The unit delivers a 125A rating with interrupt ratings of 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 50 kAIC at 600 VAC, translating to lower fault energy and minimized downtime in heavy-load environments. With 100% neutral and 50% integral or housing grounding, system balance and fault clearance are enhanced, supporting safer operations and easier maintenance in modern facilities. The plug-in format enables rapid replacements and simpler field service without extensive rewiring, while UL 857, ANSI, CSA, IEEE, and NEMA compliance provide confidence for regulatory-aligned installations in industrial plants, data centers, and distribution hubs. This combination improves lifecycle costs by reducing spare-part complexity and facilitating scalable upgrades as load profiles evolve.

Get a Quick Quote for a Eaton P3BKDC3125N

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BKDC3125N? Enquire Now

FAQs

The P3BKDC3125N is designed for Pow-R-Way III busway installations, featuring a three-pole K-frame circuit breaker that plugs directly into the busway. This compatibility minimizes integration steps, reduces field wiring, and enables faster commissioning in industrial facilities and warehouses relying on Eaton’s Pow-R-Way III family.
This unit provides a 125A amperage rating with interrupt ratings of 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 50 kAIC at 600 VAC. It offers 100% neutral and 50% integral or housing grounding, making it suitable for high-current busway applications while maintaining safe fault handling.
The P3BKDC3125N carries ANSI and CSA certifications, IEEE listing, UL 857 recognition, and NEMA compliance. This combination supports regulatory-aligned safety and performance across industrial, data-center, and distribution environments.
Yes. The plug-in design coupled with a three-pole K-frame configuration enables rapid replacement with minimal downtime. Its busway compatibility and standardized form factor reduce field modification needs, making maintenance and upgrades more predictable and cost-effective in busy production lines.
The product is covered under Eaton’s Selling Policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. This provides assurance for performance, parts availability, and access to Eaton’s distributor and technical support for sustained uptime.