Eaton P3BKDC3150G Circuit Breaker Plug-in - IEEE CSA UL 857
Part Number: P3BKDC3150G
Quick Summary
Powerful and reliable, the Eaton Pow-R-Way III circuit breaker plug-in unit protects busway distributions in industrial facilities. The plug-in design minimizes wiring complexity and accelerates commissioning, addressing the common challenge of lengthy installation times. Key certifications include UL 857, IEEE certification, CSA certification, and NEMA compliance, supporting regulatory alignment across diverse facilities. By delivering a 150A rating with a three-pole K-frame and robust protection, it enables predictable performance while simplifying spare parts planning and maintenance. This combination translates to higher uptime, lower total cost of ownership, and a scalable path for future busway expansions in growing plants.
Product Information
Extended Description
P3BKDC3150G Eaton: Eaton Pow-R-Way III circuit breaker plug-in unit, Busway, Three-pole, KDC, Plug, Breaker, K Frame (70-400 A), 150A, 200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 50 kAIC at 600 Vac, None, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKDC3150G
UPC
786683001366
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA Compliant
Certifications
IEEE Certified ANSI CSA Certified UL 857
Circuit Breaker Frame
K
Design
Pow-R-Way III
Grounding Options
50% Internal
Number Of Poles
Three-pole
Type
Breaker
Amperage Rating
150A
Interrupt rating
200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 50 kAIC at 600 Vac
Application
Busway
Product Category
Plug
Three-pole plug-in unit with a K-frame design provides rugged protection for busway installations, aligning quickly with minimal toolkit. The plug-in approach reduces field terminal connections, lowers installation time, and minimizes human error during assembly. This translates into shorter commissioning windows, less on-site disruption, and a smoother expansion path when adding new feeder sections within a live production line. The solution also supports standardized testing procedures and predictable maintenance routines by consolidating protection into a single modular unit. With a 150A amperage rating and high interrupt capability—200 kAIC at 240 Vac, 100 kAIC at 480 Vac, and 50 kAIC at 600 Vac—the device delivers immediate fault clearance for critical loads. This protects motors, drives, and instrumentation while improving coordination with upstream protective devices. In practice, engineers can confidently scale power distribution without overrating downstream equipment or sacrificing reliability during peak demand. The architecture also enables straightforward integration with existing Eaton control schemes and busway accessories. 50% Internal Grounding supports a reliable fault path inside the unit, reducing the need for extended external grounding schemes in tight enclosures. This feature simplifies panel layout in cramped spaces and enhances EMI performance in manufacturing cells with dense equipment. The grounding option also supports safer maintenance work by ensuring predictable fault paths during testing. For retrofit projects, it enables faster updates without reworking the grounding strategy across an entire panel. Compliance and certification are baked in: UL 857, IEEE certification, CSA certification, and NEMA alignment. This mix of standards simplifies supplier audits, speeds procurement, and helps meet project specs for automotive, food & beverage, and general manufacturing environments. By choosing a unit that aligns with these requirements, panel builders reduce rework and boost design confidence across the lifecycle of the installation. The product’s documented certification trail also streamlines commissioning tests and regulatory reviews. Physical attributes support install planning: dimensions of 13.29 in depth, 34.41 in height, and 7.79 in width, with an approximate weight of 53 lb. The busway-ready footprint and plug-in interface enable modular expansion and straightforward replacement, while the unit’s robust construction withstands industrial environments. Warranty coverage follows Eaton’s policy—one year from installation or eighteen months from shipment—ensuring a defined service window and predictable maintenance budgets, a key consideration for maintenance managers and spec writers alike.
Get a Quick Quote for a Eaton P3BKDC3150G
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BKDC3150G?
Enquire Now
FAQs
Plan for a three-pole, K-frame plug-in interface and ensure space for a footprint of 13.29 in depth, 34.41 in height, and 7.79 in width. The unit weighs 53 lb and is designed for busway distribution, enabling faster commissioning and minimizing field wiring. Verify enclosure fit and ensure proper alignment with compatible busway components to maintain protective coordination.
The device is rated for 150A, with interrupt ratings of 200 kAIC at 240 Vac, 100 kAIC at 480 Vac, and 50 kAIC at 600 Vac. This enables rapid fault clearance for critical loads and supports coordination with upstream protection devices, allowing scalable protection for motors, drives, and feeders in busway systems.
It carries IEEE Certified, ANSI CSA Certified, and UL 857 with NEMA compliance. These certifications simplify regulatory audits, streamline procurement, and help meet project specs across automotive, manufacturing, and general industrial environments, reducing rework and accelerating approvals.
The unit offers 50% internal grounding, providing a reliable fault path inside the module and reducing the need for extensive external grounding in tight enclosures. This supports improved EMI performance and safer maintenance in dense, high-traffic panels.
Warranty follows Eaton’s policy: one year from date of installation or eighteen months from date of shipment, whichever occurs first. This coverage assists with maintenance budgeting and ensures support for field replacements or component refurbishments during the early lifecycle of the installation.