Eaton Pow-R-Way III circuit breaker plug-in unit protects feeder circuits in industrial busway systems. In fast-moving electrical environments, downtime and wiring errors can drive costly outages; this plug-in unit is designed for quick, reliable protection with straightforward maintenance. It carries IEEE Certified, CSA Certified, and UL 857 certifications to meet rigorous safety and performance standards, and it remains NEMA compliant for rugged field use. With 50% internal grounding and 100% neutral options, fault paths are better managed and wiring is simplified. The solution provides a 400A amperage rating and high interrupt ratings, delivering dependable protection in demanding plant distributions while fitting the compact Pow-R-Way III busway architecture.
Product Information
Extended Description
P3BKDC3400GN Eaton: Pow-R-Way III Busway, Circuit Breaker Plug-in Unit, 3-Pole, 400 AMP, KDC Frame Type, 50% Internal Ground and 100% Neutral
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BKDC3400GN
UPC
786683001663
Product Length/Depth
13.29 in
Product Height
34.41 in
Product Width
7.79 in
Product Weight
53 lb
Compliances
NEMA Compliant
Certifications
IEEE Certified CSA Certified ANSI UL 857
Circuit Breaker Frame
K
Grounding Options
50% Internal
Type
Breaker
Amperage Rating
400A
Interrupt rating
200 kAIC at 240 Vac, 100 kAIC at 480 Vac, 50 kAIC at 600 Vac
Neutral Options
100%
Feature: 400A amperage rating with 200 kAIC interrupt capacity ensures robust short-circuit protection for high-load busway feeders. Business Impact: Reduces arc exposure and protects critical equipment, lowering risk of unplanned downtime. Application: Suitable for large manufacturing lines and distribution panels powered by Pow-R-Way III busways. Feature: 3-Pole, K frame breaker with plug-in unit configuration simplifies replacement and maintenance. Business Impact: Enables fast swaps and easy upgrades without extensive wiring work, reducing maintenance time by hours per year. Application: Ideal for modular power distribution setups in compact switchgear enclosures. Feature: Grounding Options of 50% Internal and 100% Neutral. Business Impact: Improves fault path management and neutral return accuracy, enhancing system stability during faults. Application: Critical in facilities requiring precise grounding schemes and reliable fault clearance. Feature: Compliance and certifications including IEEE Certified, CSA Certified, and UL 857 with NEMA compliance. Business Impact: Streamlines regulatory approvals and audits, reducing project risk. Application: Essential for industrial facilities with rigorous safety and performance standards. Feature: Compact physical footprint with dimensions 13.29 in L x 34.41 in H x 7.79 in W and 53 lb weight. Business Impact: Facilitates integration into crowded switchgear spaces and reduces enclosure rework. Application: Fits standard Pow-R-Way III busway compartments for scalable distribution.
Get a Quick Quote for a Eaton P3BKDC3400GN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BKDC3400GN?
Enquire Now
FAQs
For proper installation, mount the unit as a 3-pole breaker plug-in within the Pow-R-Way III busway sections, ensuring alignment with the K-frame housing and compatible enclosure depth. Confirm 13.29 in length, 34.41 in height, and 7.79 in width fit within the designated compartment, and connect grounding per the 50% internal grounding option while leveraging 100% neutral if required by the circuit design.
This unit features a 400A amperage rating and a 200 kAIC interrupt rating at 240 VAC, with lower ratings at higher voltages (100 kAIC at 480 VAC, 50 kAIC at 600 VAC). These specs indicate strong fault-current capability for rapid clearance and reduced equipment damage, suitable for heavy-duty busway feeds in industrial environments.
Yes. The product carries IEEE Certified, CSA Certified, and UL 857 certifications, along with NEMA compliance. This combination supports regulatory acceptance, safer operation, and reliable performance in regulated industrial facilities, helping with audits and safety program requirements.
The unit uses a K-frame breaker compatible with Pow-R-Way III busways, designed for plug-in installation. Verify the enclosure supports the unit’s dimensions and confirm grounding options align with facility grounding practices. The 13.29 in L x 34.41 in H x 7.79 in W size supports compact installations while maintaining serviceability.
The plug-in design minimizes downtime during replacement, reducing maintenance labor and troubleshooting time. High interrupt ratings reduce the likelihood of arc-related damage, while 50% internal grounding and 100% neutral options simplify fault management and wiring. Together, these features support longer mean time between outages and lower total cost of ownership.