Eaton P60G11S0712CU Mini-Power Center - UL Listed
Part Number: P60G11S0712CU
Quick Summary
The Eaton P60G11S0712CU Mini-Power Center is a compact single-phase transformer package designed for reliable power distribution in industrial panels and commercial equipment. It consolidates transformer, enclosure, and wiring access into one rugged unit, helping engineers overcome space constraints and procurement complexity. This product carries ANSI IEEE Certified, UL Listed, and CSA Certified marks, ensuring regulatory compliance and safe operation across diverse markets. With a 7.5 kVA rating, primary 600 V and secondary 120/240 V, it supports critical control circuits and auxiliary feeds while minimizing voltage drop in moderate-load environments. Wall-mount installation, robust copper windings, and a NEMA 3R enclosure translate to improved uptime, easier service, and consistent performance in demanding industrial settings.
Product Information
Extended Description
P60G11S0712CU Eaton: 7.5 KVA Mini Power Center 1PH 600-120/240 115C RISE 12 spaces
Product Name
Eaton Mini-Power center
Catalog Number
P60G11S0712CU
UPC
786680226366
Product Length/Depth
8.9 in
Product Height
29.5 in
Product Width
11.9 in
Product Weight
200 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NAFTA
Certifications
ANSI IEEE Certified UL Listed CSA Certified
Coil material
Copper
Enclosure
NEMA 3R
Frame
284
Insulation
180 °C
Mounting
Wall Mount
Tap size
2 at -5% FCBN
Type
Mini-power center
Wiring connection
M60G11E
Frequency rating
60 Hz
kVA
7.5 kVA
Kva Rating
7.50 kVA
Phase
Single-phase
Primary voltage
600 V
Secondary Voltage
120/240 V
Sound Level
NEMA ST-20
Temperature rise
115 °C rise
Volt ampere rating
7.5 kVA
Modification 1
NEMA 3R
Weathershield
Not required
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton's Transformer Flex Center
Eaton Specification Sheet - P60G11S0712CU
7.5 kVA single-phase transformer with a 600 V primary and 120/240 V secondary provides scalable power for control panels and machine wiring. Business impact: increased headroom reduces nuisance tripping and short-circuit stress while enabling simpler circuit design for automation systems. Application: ideal for panel boards in manufacturing lines and commercial equipment rooms. Copper winding construction offers high electrical conductivity and reliability, improving thermal performance and reducing energy losses over time. Business impact: lower maintenance cost and longer service life in high-load environments; Application: frequent start‑ups of motors and drives. NEMA 3R enclosure with wall-mount capability supports outdoor or partially sheltered installations; Business impact: outdoor-ready deployment without costly weather shields; Application: facility exteriors or protected outdoor enclosures. Tap size of 2 at -5% FCBN and wiring connection M60G11E enable flexible voltage regulation and straightforward field wiring; Business impact: minimizes voltage mismatch risk and accelerates installation; Application: field adjustability for evolving electrical loads. Insulation rated to 180 °C and temperature rise of 115 °C deliver robust thermal margins; Business impact: enhanced safety and reliability during peak loading; Application: harsh industrial climates and continuous operation. The unit’s weight (200 lb) and dimensions (29.5 in H × 11.9 in W × 8.9 in D) guide install planning and mounting clearances; Business impact: streamlined space planning and compliance with footprint requirements; Application: retrofit in existing panels or new builds. Certifications ANSI IEEE Certified, UL Listed, CSA Certified and NAFTA compliance reduce procurement risk; Business impact: faster approvals and unified supplier ecosystem; Application: regulated facilities and cross-border projects. Warranty terms (one year from installation or 18 months from shipment) provide predictable total cost of ownership and support during initial deployment; Application: risk management for capital projects.
Get a Quick Quote for a Eaton P60G11S0712CU
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P60G11S0712CU?
Enquire Now
FAQs
The P60G11S0712CU uses a NEMA 3R enclosure suitable for outdoor or semi-exposed locations, with a wall-mount design to simplify installation. Ensure adequate clearance for ventilation and access to taps, and use appropriate weather-protected conduit entries. The M60G11E wiring connection supports standard field wiring practices, aiding a straightforward, code-compliant setup.
This unit provides a 7.5 kVA single-phase transformer with a 600 V primary and 120/240 V secondary, optimized for control panels and machine feeds. The copper windings and 60 Hz rating deliver reliable voltage conversion with low losses, supporting PLCs, drives, and control circuits while maintaining voltage stability during load fluctuations.
Yes. The transformer uses standard connection practices (M60G11E) and a common 7.5 kVA rating compatible with Eaton and many third-party distribution panels. Its wall-mount, NEMA 3R enclosure and copper windings simplify integration into existing enclosures, enabling smoother retrofits and consistent electrical performance across Eaton-powered systems.
The unit carries ANSI IEEE certification, UL listing, and CSA certification, with NAFTA compliance. These marks support regulatory approvals, supplier qualification, and cross-border procurement, reducing the risk of non-compliance during audits or inspections in manufacturing, healthcare, and data-center environments.
With a 7.5 kVA rating and durable copper windings, the transformer delivers reliable service with low energy losses and minimal maintenance. The one-year warranty (or 18 months from shipment) protects initial deployments, while a robust enclosure and installation flexibility reduce downtime and field service visits—resulting in lower lifecycle costs and faster project payback.