Eaton PXM1K-BIPP Power Xpert Meter 1000 - BACnet/IP
Part Number: PXM1K-BIPP
Quick Summary
The Eaton PXM1K-BIPP Power Xpert meter 1000 communication module provides BACnet/IP connectivity for energy monitoring and building automation across commercial and industrial facilities. This module is designed to simplify integration, reducing commissioning time and data silos that hinder real-time insight. While many users struggle with disparate metering data, this card offers a unified communication path and web push capabilities to keep operators informed. Expect verified performance in 60 Hz environments with Modbus TCP alongside BACnet/IP, enabling smooth interoperability with existing control systems. The business value is clear: faster deployments, improved energy visibility, and proactive maintenance support, powered by a compact, reliable comms card that fits your Eaton Power Xpert Meter 1000 ecosystem.
Product Information
Extended Description
PXM1K-BIPP Eaton: Eaton Power Xpert meter 1000 communication module, BACnet/IP and Modbus TCP with Web/HTTP Push
Product Name
Eaton Power Xpert meter 1000 communication module
Catalog Number
PXM1K-BIPP
UPC
786687034940
Product Length/Depth
2.9 in
Product Height
1 in
Product Width
2.25 in
Product Weight
0.2 lb
Warranty
1 year
Compliances
Contact Manufacturer
Type
Comm Card
Used with
PXM1000
Communication
BACnet/IP
Frequency rating
60 Hz
Power Xpert Meters
Power Xpert Meters
Power Xpert Meter 1000 meter software version 3.7.3
Eaton Specification Sheet - PXM1K-BIPP
Feature → Business Impact → Application: BACnet/IP and Modbus TCP communications provide versatile integration with predominant building management systems, resulting in faster project timelines and a reduction in engineering hours. This dual-protocol capability reduces the need for multiple gateways and simplifies fleet-wide monitoring of energy usage, improving accuracy and reliability across facilities. Application: data centers, campuses, and manufacturing plants benefit from centralized energy data that supports demand response and peak shaving strategies, ultimately lowering operating costs. Feature → Web/HTTP Push notifications and remote visibility enable proactive alerts and quick fault isolation, reducing downtime and maintenance expense. Application: remote sites and distributed facilities gain immediate situational awareness without site visits, improving uptime and service levels. Feature → Compact form factor (2.9 in L, 1 in H, 2.25 in W) and lightweight (0.2 lb) design simplify retrofit and new installations, lowering installation time and vibration concerns in panel environments. Application: upgrades to legacy meters and new builds where space is at a premium. Feature → 1-year warranty and Eaton support create a predictable total cost of ownership and robust post-installation assistance. Application: procurement and operations teams gain confidence in long-term reliability. The module’s compatibility with PXM1000 ensures a seamless upgrade path and consistent data schemas for scalable energy programs, while the 60 Hz electrical specification matches common power infrastructure in many regions. Overall, the PXM1K-BIPP enables accelerated time-to-value for energy visibility initiatives and durable system integration with minimal risk.
Get a Quick Quote for a Eaton PXM1K-BIPP
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton PXM1K-BIPP?
Enquire Now
FAQs
Installation is straightforward when pairing the PXM1K-BIPP with the PXM1000 unit. Verify that your control system supports BACnet/IP and Modbus TCP protocols and confirm the site operates at 60 Hz. Ensure proper panel mounting clearance, connect the comm card per Eaton’s wiring diagrams, and perform a commissioning checklist that includes device discovery, IP addressing, and test messaging to BACnet/IP and Modbus TCP endpoints.
The module supports dual communication protocols, enabling seamless data exchange with most building management and energy management systems. This reduces gateway complexity, accelerates data consolidation, and improves interoperability across vendor equipment. In energy projects, you can leverage real-time metrics for demand response, peak shaving, and fine-grained monitoring without custom adapters.
Designed for use with Power Xpert Meter 1000 devices, the PXM1K-BIPP fits the intended delivery program as a Comm Card. Plan for panel space, ensure proper cabling access, and align network addressing with your IT/OT security policies. Post-install, validate communication with test commands and confirm that data is populating in your energy monitoring dashboards.
The data sheet indicates Compliances: Contact Manufacturer, so verify with Eaton for CE marking, IP rating, and any SIL-related certifications applicable to your installation. It is essential to confirm regulatory compliance for your region and whether additional certifications are needed for safety and reliability in your specific application.
Expected ROI comes from faster integration, reduced commissioning labor, and improved energy insight for operational optimization. The module carries a 1-year warranty, with Eaton support available for ongoing maintenance and firmware updates. Regular health checks on BACnet/IP and Modbus TCP endpoints help sustain data integrity and minimize unplanned downtime.