Eaton enclosed meter PXM3000MA15-2A4AAS2 - CE
Part Number: PXM3000MA15-2A4AAS2
Quick Summary
Eaton enclosed meter provides precise energy monitoring for panel boards and industrial facilities. This compact, four-meter enclosure delivers accurate, centralized visibility across all feeders, helping teams optimize energy use and reduce demand charges. The device is designed to withstand demanding environments and deliver reliable data with 0.2% accuracy per ANSI/IEEE C12.20 and IEC 687 standards, while CE marking ensures global compliance. With native Modbus RTU/TCP, BACnet/IP, SNMP, and DNP connectivity, it integrates smoothly into modern building and process control architectures. By consolidating four meters in a single NEMA 12 enclosure, it simplifies installation, reduces panel footprint, and accelerates commissioning—delivering tangible business value and faster ROI through better energy insight and fault detection.
Product Information
Extended Description
PXM3000MA15-2A4AAS2 Eaton: 4-PXM3000(MA15,No Optional I/O),NEMA12(120/240V,No CPT),4-3PH/4W Main Fuse Disconnect (one per PXM),Control Power Fuse Disconnect per PXM,CT Shorting Block per PXM,
Product Name
Eaton enclosed meter
Catalog Number
PXM3000MA15-2A4AAS2
UPC
786687080367
Product Length/Depth
24 in
Product Height
12 in
Product Width
30 in
Product Weight
100 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
120/240V
Power supply
120/240 Vac
Enclosure
NEMA 12
Enclosure size
30inH x 24inW X 12inD
Number of meters
4
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
Modbus RTU/TCP, BACnet/IP, SNMP, DNP
Metering devices, protective relays, software and connectivity
Metering devices, protective relays, software and connectivity
Eaton's Enclosed Meters
Feature: Four-meter, four-channel energy measurement in a single enclosure reduces wiring and panel footprint. This integrated approach speeds commissioning and ensures synchronized data across all feeders for accurate, holistic energy management. Business Impact: Lower wiring costs, faster project timelines, and consistent energy data across multiple circuits. Application: Ideal for multi-feed panels in manufacturing floors and data centers seeking unified energy monitoring. Enclosure and electrical specs support safe deployment in industrial environments: a NEMA 12 enclosure handles 120/240 Vac operation, with a four-puse? main fuse disconnect per PXM, plus a CT shorting block per PXM. This configuration simplifies field wiring, improves fault isolation, and ensures regulatory compliance during commissioning. Business Impact: Safer installations, reduced commissioning time, and improved maintenance traceability. Application: Ideal for compliant installations in control panels and switchgear rooms. Connectivity options enable integration with existing automation stacks: Modbus RTU/TCP, BACnet/IP, SNMP, and DNP provide flexible data access. The meter faceplate offers clear local visibility, while four meters inside one box support scalable deployment in plants, data centers, and process lines. Business Impact: Enhanced SCADA integration, real-time monitoring, and scalable asset management. Application: Builds resilience in energy dashboards and demand-response programs. Physical footprint and weight support installation in limited spaces: 30 in H x 24 in W x 12 in D, approximately 100 lb, enabling straightforward mounting in typical electrical rooms. With 0.2% accuracy per ANSI/IEEE C12.20 and IEC 687 and CE marking, the unit delivers reliable revenue-grade data for compliance and optimization. Business Impact: Lower lifecycle costs, reliable billing data, and smoother audits. Application: Suitable for large-scale commercial and industrial deployments requiring precise energy accounting.
Get a Quick Quote for a Eaton PXM3000MA15-2A4AAS2
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton PXM3000MA15-2A4AAS2?
Enquire Now
FAQs
Yes. The PXM3000MA15-2A4AAS2 is designed to house four meters within a NEMA 12 enclosure rated for 120/240 Vac operation. This configuration simplifies panel layouts, reduces wiring complexity, and supports reliable commissioning while maintaining compliance with common industrial enclosures.
The meter features 0.2% accuracy per ANSI/IEEE C12.20 and IEC 687, with CE Marking for global use. It operates at 50/60 Hz and supports 120/240 V, delivering revenue-grade data suitable for billing, energy management, and compliance reporting in industrial environments.
Ideal for multi-feed panel applications in manufacturing, data centers, and process plants, the device provides Modbus RTU/TCP, BACnet/IP, SNMP, and DNP connectivity. This enables seamless integration with SCADA, BMS, and energy dashboards, delivering centralized visibility across feeders and improved demand management.
Compliance is supported by CE marking and ANSI/IEEE C12.20 IEC 687 certification. Installation considerations include using the 30inH x 24inW x 12inD enclosure, accounting for a 100 lb weight, proper cabling to the 120/240V supply, and ensuring correct fuse disconnects per PXM for safe operation.
Consolidating four meters into one enclosure reduces wiring, inventory, and field labor, accelerating commissioning and enabling centralized data analytics. The unit’s reliable 0.2% accuracy and durable NEMA 12 enclosure support long-term energy visibility, contributing to faster payback through improved energy efficiency and reduced maintenance overhead.