Eaton PXM3000MA15-2A4E Enclosed Meter - ANSI/IEEE 0.2%

Part Number: PXM3000MA15-2A4E
Eaton logo
Manufacturer
Eaton
Part number
PXM3000MA15-2A4E

Quick Summary

Eaton enclosed meter is a reliable energy measurement solution for industrial panel power distribution. For engineers and procurement teams, the challenge is obtaining accurate, multi-circuit data without sacrificing enclosure protection in harsh environments. This unit carries ANSI/IEEE Std C12.20 (0.2% accuracy) and IEC 687 (0.2%), with CE Marking, ensuring measurement integrity across global facilities. By combining four meters in a single NEMA 12 enclosure with a robust 24x24x12 in footprint, it minimizes panel space and wiring complexity. The integrated Modbus RTU/TCP, BACnet/IP, SNMP, and DNP capabilities facilitate seamless data exchange with your MES, SCADA, and building automation systems. In short, you gain reliable energy insight, faster commissioning, and a scalable foundation for ongoing energy management initiatives.

Product Information

Extended Description

PXM3000MA15-2A4E Eaton: 4-PXM3000(MA15,No Optional I/O),NEMA12(120/240V,No CPT),1-3PH/4W Main Fuse Disconnect,Control Power Fuse Disconnect per PXM,CT Shorting Block per PXM,6-port Ethernet Switch with Vdc Power Supply, each PXM CAT5/6 to open Ethernet Switch Port
Product Name
Eaton enclosed meter
Catalog Number
PXM3000MA15-2A4E
UPC
786687080381
Product Length/Depth
24 in
Product Height
12 in
Product Width
24 in
Product Weight
100 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
120/240V
Power supply
120/240 Vac
Enclosure
NEMA 12
Enclosure size
24inH x 24inW x 12inD
Number of meters
4
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
Modbus RTU/TCP, BACnet/IP, SNMP, DNP
Protected enclosure, NEMA 12, guards the meter inside against dust, moisture, and corrosion, extending service life in demanding industrial environments. This reduces unplanned maintenance and downtime, delivering more reliable data even in hot, dirty, or humid factory floors. It is ideal for panel-mounted energy monitoring in manufacturing lines and utility rooms where reliability is non-negotiable. Four meters integrated in a single 24x24x12 in enclosure save cabinet space and simplify wiring. The multi-circuit capability enables true per-feed or per-phase energy insight without deploying separate meters, lowering installation time and capital cost. This setup supports scalable energy management across growing facilities. Built-in six-port Ethernet switch with DC power enables plug-and-play network integration. With Modbus RTU/TCP, BACnet/IP, SNMP, and DNP support, it aligns with standard automation stacks and SCADA systems, reducing engineering time and risk of data silos. The on-device switch simplifies topology and improves data latency for real-time energy analytics. Certified accuracy and compliance are central to this meter: ANSI/IEEE C12.20 0.2% accuracy and ANSI/IEEE C62.41, IEC 687 0.2% recognized performance metrics, plus CE marking for European use. This combination boosts confidence in energy reporting, supports regulatory reporting, and minimizes audit findings. Operators gain trusted data for chargeback, demand response, and energy budgeting. With 120/240 VAC power, 50/60 Hz operation, and a 24x24x12 enclosure, the PXM3000MA15-2A4E slides into standard industrial panels and MES-ready networks. Its rugged design reduces field service calls and supports long-term maintenance strategies. For engineers, it's a future-proof foundation for expanding metering and smarter energy workflows.

Get a Quick Quote for a Eaton PXM3000MA15-2A4E

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXM3000MA15-2A4E? Enquire Now

FAQs

Install the unit in a standard 24x24 inch enclosure with proper ventilation. Mount securely to support the 100 lb weight, route CAT5/6 cables to the built-in 6-port Ethernet switch, connect to 120/240 VAC, and verify 50/60 Hz compatibility. Ensure cable entry seals maintain NEMA 12 protection and minimize thermal buildup for stable metering.
The meter uses ANSI/IEEE C12.20 compliant measurement with 0.2% accuracy, plus IEC 687 evaluation. This high-precision data improves chargeback, energy budgeting, and regulatory reporting, reducing discrepancies between measured and billed energy and supporting accurate demand-response programs.
Yes. The PXM3000MA15-2A4E provides comprehensive protocol support, enabling seamless data sharing with standard SCADA, MES, and building automation systems. This reduces wiring complexity, accelerates data unification, and enables real-time energy analytics across multiple facility subsystems without separate meters.
The meter is CE compliant and carries ANSI/IEEE Std C12.20 (0.2% accuracy), ANSI/IEEE Std C62.41, and IEC 687 (0.2% accuracy). These certifications support regulatory compliance, enable cross-border deployment, and bolster confidence in long-term metering integrity for audits.
By combining four meters in one enclosure and integrating a robust Ethernet switch, this solution reduces panel space, wiring, and installation time. The durable NEMA 12 enclosure lowers maintenance downtime, while accurate, network-enabled data supports proactive energy management and faster fault detection, delivering a favorable total cost of ownership over time.