Eaton PXM3000MA15-2B6AS10 Enclosed Meter - NEMA 12

Part Number: PXM3000MA15-2B6AS10
Eaton logo
Manufacturer
Eaton
Part number
PXM3000MA15-2B6AS10

Quick Summary

Eaton enclosed meter is a rugged power monitoring solution for industrial panels and electrical rooms. Engineers often struggle with limited visibility and scalability in complex power architectures, which this unit addresses by delivering dual 480V 3-phase metering with provisions for future expansion. Key attributes include a NEMA 12 enclosure for indoor protection, BACnet/IP and Modbus RTU/TCP communications for seamless integration with building management and control systems, and a scalable architecture that supports evolving metering needs. This combination provides timely energy data, improved operational awareness, and a clear path to compliant reporting, while aligning with existing automation platforms and business processes.

Product Information

Extended Description

PXM3000MA15-2B6AS10 Eaton: 2-PXM3000(MA15,No Opt I/O),Provisions for future 4-PXM3k,NEMA12(480V),1-480V 3PH/4W Main Fuse Disconnect(PXM3k#1),1-208V 3PH/4W MFD(PXM3k#2),4-480V 3PH/4W MFD(future PXM3k),6-Door mounted ETH Jack,CT Shorting Blocks
Product Name
Eaton enclosed meter
Catalog Number
PXM3000MA15-2B6AS10
UPC
786689857950
Product Length/Depth
12 in
Product Height
30 in
Product Width
24 in
Product Weight
122 lb
Voltage rating
480V
Power supply
480V
Enclosure
NEMA 12
Enclosure size
30inH x 24inW x 12inD
Number of meters
2
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
BACnet/IP Modbus RTU/TCP
Degree of protection
NEMA 12
Feature Dual-meter capability enables simultaneous monitoring of two independent loads → Business Impact Enables accurate energy accounting and demand profiling across critical processes → Application Ideal for panel boards and electrical rooms in manufacturing facilities. Feature NEMA 12 enclosure provides rugged indoor protection → Business Impact Reduces maintenance, minimizes dust and moisture ingress, and extends component life → Application Indoor industrial environments with stringent cleanliness and reliability requirements. Feature BACnet/IP and Modbus RTU/TCP communications → Business Impact Simplifies integration with building management systems and SCADA, improving data centralization and control → Application New installations or retrofits in facilities pursuing standard automation protocols. Feature Provisions for future 4-PXM3k expansion and CT shorting blocks → Business Impact Future-proofing reduces total cost of ownership and downtime during upgrades → Application Long-term utility in plants planning phased meter rollouts. Feature Display on meter faceplate and two meters per enclosure → Business Impact Intuitive visualization speeds commissioning and troubleshooting, shortening project timelines → Application Quick-start for engineers during installation. Feature 480V 50/60 Hz operation and 3PH/4W configuration → Business Impact Broad compatibility with common industrial power systems, reducing rewiring risk and compatibility issues → Application Suitable for mainstream industrial facilities seeking reliable power monitoring and easy integration.

Get a Quick Quote for a Eaton PXM3000MA15-2B6AS10

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXM3000MA15-2B6AS10? Enquire Now

FAQs

The unit requires a suitable 30inH x 24inW x 12inD enclosure with a 122 lb weight class, two meter slots, and CT shorting blocks. Ensure mounting supports are rated for this weight, and verify clearance for the door-mounted ETH jack and future I/O expansion provisions. Pre-plan wire routing to minimize interference with MFDs and main disconnects.
Operating at 480V with 50/60 Hz, the PXM3000MA15-2B6AS10 supports 3-phase/4-wire configurations. It includes a main fuse disconnect for the PXM3k section and provisions for a future 4-PXM3k, along with CT shorting blocks. Follow local electrical codes for conductor sizing, routing, and protective enclosures to ensure safe commissioning.
Yes. The device offers BACnet/IP and Modbus RTU/TCP communications, enabling seamless integration with modern building management systems and SCADA platforms. This interoperability supports centralized energy monitoring, demand management, and export of metering data to analytics dashboards, improving operational visibility and control.
Absolutely. The design includes provisions for a future 4-PXM3k along with CT shorting blocks, allowing phased expansion without replacing the meter housing. This reduces downtime and total cost of ownership as facility power monitoring needs grow or change.
Routine maintenance is minimized by the rugged NEMA 12 enclosure and robust wiring ground for indoor environments. ROI is driven by improved energy visibility, faster fault isolation, and regulatory reporting efficiency, which collectively reduce energy waste and support more informed procurement and process optimization decisions.