Eaton PXM3000MA15-2B6AS8 Enclosed Meter - NEMA 12

Part Number: PXM3000MA15-2B6AS8
Eaton logo
Manufacturer
Eaton
Part number
PXM3000MA15-2B6AS8

Quick Summary

The Eaton enclosed meter provides accurate energy measurement for electrical panels in industrial facilities. Installing metering in harsh environments can complicate wiring, access, and compliance with safety procedures. This model uses a rugged NEMA 12 enclosure and supports 480V systems at 50/60 Hz, with room for future expansion via CT blocks and a door-mounted ETH jack. While explicit SIL, CE, or IP ratings aren’t listed in the provided data, the enclosure and communication options deliver reliable protection and integration. For engineers evaluating efficiency gains or predictive maintenance, this solution pairs well with BACnet/IP and Modbus RTU/TCP networks, delivering clear value for energy visibility and utility-grade reporting within industrial power management workflows.

Product Information

Extended Description

PXM3000MA15-2B6AS8 Eaton: 1-PXM3000(MA15,No Opt I/O),Provisions for 5-PXM3k,NEMA12(480V),1-480V 3PH/4W Main Fuse Disconnect(PXM3k#1),5-480V 3PH/4W MFD(future PXM3k),6-Door mounted ETH Jack,CT Shorting Blocks
Product Name
Eaton enclosed meter
Catalog Number
PXM3000MA15-2B6AS8
UPC
786689857936
Product Length/Depth
12 in
Product Height
30 in
Product Width
24 in
Product Weight
122 lb
Voltage rating
480V
Power supply
480V
Enclosure
NEMA 12
Enclosure size
30inH x 24inW x 12inD
Number of meters
1
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
BACnet/IP Modbus RTU/TCP
Degree of protection
NEMA 12
Rugged enclosure and compact footprint: The 30inH x 24inW x 12inD NEMA 12 enclosure protects the enclosed meter’s electronics in dusty or damp industrial spaces, reducing field maintenance and extending service life. The 122 lb weight and sturdy panel mount simplify installation in control rooms and switchgear areas. Future-ready expansion: Provisions for up to five PXM3k meters and a future 1-480V 3PH/4W main disconnect support scalable energy monitoring, protecting capital through phased upgrades while keeping current installations intact. This enables multi-point metering without panel redesign. Integrated communications: BACnet/IP and Modbus RTU/TCP enable seamless integration with EMS/SCADA, reducing data silos and accelerating commissioning. CT shorting blocks and a door-mounted ETH jack simplify wiring and remote access. Readiness for installation and service: Faceplate display provides quick reads for technicians and improves fault diagnosis, while the enclosure’s protective features support long-term reliability.

Get a Quick Quote for a Eaton PXM3000MA15-2B6AS8

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXM3000MA15-2B6AS8? Enquire Now

FAQs

Plan for a 480V, 3‑phase, 4‑wire distribution and place the meter in a clean, accessible enclosure. Mount the unit on a sturdy panel, install CT shorting blocks as required, and connect the 1‑main fuse disconnect if you enable the PXM3k option. Then attach the ETH jack and communication cables, set 50/60 Hz, and verify readings on the faceplate.
This meter supports BACnet/IP and Modbus RTU/TCP, enabling seamless integration with building management systems, SCADA, and energy management software. Configure IP addressing for BACnet, assign Modbus registers, and validate data accuracy across devices. The communications flexibility reduces project risk and accelerates commissioning while delivering consistent energy data to central dashboards.
Yes. The PXM3000MA15-2B6AS8 is designed for 480V operation with 50/60 Hz and includes a 1‑meter, 480V 3‑phase/4‑wire main disconnect option. It ships in a NEMA 12 enclosure and provides provisions for future expansion using additional PXM3k modules, offering scalable metering for growing plant distributions. This combination supports phased upgrades without panel redesign, reducing downtime and capital spend.
The enclosure dimensions are 30 inches high by 24 inches wide by 12 inches deep, with a total weight of 122 pounds. This footprint suits wall-mount or stand-up installations in electrical rooms or control panels. The meter’s faceplate display is designed for quick field readings, while CT shorting blocks and the ETH jack are positioned for straightforward wiring and service access.
The unit provides provisions for future expansion with up to five PXM3k modules, CT shorting blocks, and a door-mounted ETH jack. This design supports scaling to additional metering points across a facility, minimizes retrofit complexity, and maintains consistent interface standards for BACnet/IP and Modbus RTU/TCP as you grow. Simplifying project planning and delivering faster ROI.