Eaton PXM3000MA15-2B6AS9 Enclosed Meter - NEMA 12
Part Number: PXM3000MA15-2B6AS9
Quick Summary
Eaton enclosed meter provides precise three-channel power monitoring for switchgear and control panels. Engineers and procurement teams often grapple with integrating multiple meters into a single, install-ready enclosure without sacrificing data access. This module combines a NEMA 12 enclosure with BACnet/IP and Modbus RTU/TCP, delivering network-ready metering in challenging industrial environments. With a 480V rating and 50/60 Hz compatibility, it fits standard power systems and streamlines compliance reporting. Together with front-access display options and scalable architecture, it supports centralized energy management while reducing wiring complexity and lifecycle costs.
Product Information
Extended Description
PXM3000MA15-2B6AS9 Eaton: 3-PXM3000(MA15,No Opt I/O),Provisions for 3-PXM3k,NEMA12(480V),1-480V 3PH/4W Main Fuse Disconnect(PXM3k#1),1-480V 3PH/4W MFD(PXM3k#2),1-480V 3PH/4W MFD(PXM3k#3),3-480V 3PH/4W MFD (future PXM3k),6-Door mounted ETH Jack,CT Shorting Blocks
Product Name
Eaton enclosed meter
Catalog Number
PXM3000MA15-2B6AS9
UPC
786689857943
Product Length/Depth
12 in
Product Height
30 in
Product Width
24 in
Product Weight
122 lb
Voltage rating
480V
Power supply
480V
Enclosure
NEMA 12
Enclosure size
30inH x 24inW x 12inD
Number of meters
3
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
BACnet/IP Modbus RTU/TCP
Degree of protection
NEMA 12
Feature: Three-channel metering consolidated in a single enclosure means you wire once and monitor three loads simultaneously. Business Impact: reduces wiring complexity and field wiring errors, speeds commissioning, and simplifies data consolidation across devices. Application: ideal for panel boards and switchgear in manufacturing and process facilities. Paragraph two focuses on the rugged enclosure and voltage suitability. Feature: NEMA 12 enclosure plus 480V rating provides robust protection against dust and incidental moisture in harsh environments. Business Impact: enhances reliability, minimizes unplanned downtime, and supports long-term installation in factory floors. Application: suitable for industrial environments with demanding ingress protection needs. Paragraph three covers communications. Feature: BACnet/IP and Modbus RTU/TCP enable seamless integration with building management and SCADA systems. Business Impact: improves visibility, enables remote monitoring, and reduces points of failure during data collection. Application: energy management, facilities automation, and plant-wide instrumentation. Paragraph four highlights expandability. Feature: Provisions for 3-PXM3k, MFDs, 6-door ETH Jack, and CT shorting blocks offer scalable metering and future upgrades. Business Impact: lowers total cost of ownership by avoiding early replacement and speeding up upgrades. Application: plant modernization and incremental capacity planning. Paragraph five covers display and installation. Feature: Meter Faceplate display and defined enclosure size (30inH x 24inW x 12inD) streamline operator access and cabinet integration. Business Impact: simplifies commissioning and improves commissioning accuracy for technicians. Application: compact, high-visibility metering in control panels and electrical rooms.
Get a Quick Quote for a Eaton PXM3000MA15-2B6AS9
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton PXM3000MA15-2B6AS9?
Enquire Now
FAQs
Installation begins with mating the unit to a compatible 480V 3‑phase panel and securing it within a NEMA 12 enclosure. Route three phase conductors to the meter inputs, connect CT shorting blocks as required for current measurement, and terminate communication wires to BACnet/IP and Modbus RTU/TCP. Use the ETH Jack for network access and ensure front access for the Meter Faceplate display. Follow the installation manual for torque specs and clearance.
The meter supports three channels across 480V, 50/60 Hz, in a 3‑phase, 4‑wire configuration. Communications include BACnet/IP and Modbus RTU/TCP, enabling integration with modern BMS and SCADA systems. It ships in a 30inH x 24inW x 12inD enclosure with a NEMA 12 rating, and provides a 3‑meter measurement scope with a front display for quick verification.
Yes. The PXM3000MA15-2B6AS9 is designed for panel boards, switchgear, and automation racks requiring centralized, multi‑channel metering. Its three‑meter capability reduces wiring complexity, while BACnet/IP and Modbus RTU/TCP support enables real‑time energy monitoring and control from a single data source on compliant automation networks.
The enclosure is NEMA 12 rated, offering protection against dust and non‑excessive moisture typical of indoor industrial environments. Electrical specifications include 480V operation and 50/60 Hz compatibility. While SIL or CE certifications aren’t listed, the enclosure and ratings are aligned with common industrial safety and performance standards for control panel metering.
Centralizing three meters in one enclosure reduces panel wiring, simplifies commissioning, and enables unified data logging and reporting for energy management. The modular architecture supports future upgrades (PXM3k expansion, additional MFDs), reducing retrofit downtime and extending the life of the metering solution in evolving facilities.