Eaton Enclosed Meter PXM350MA6121-2A3A - 0.2% ANSI/IEEE CE

Part Number: PXM350MA6121-2A3A
Eaton logo
Manufacturer
Eaton
Part number
PXM350MA6121-2A3A

Quick Summary

An Eaton enclosed meter provides 3‑phase power monitoring for panel-level electrical distributions in industrial facilities. It helps engineers overcome data gaps, installation complexity, and limited visibility into energy use across multiple feeders. The unit carries CE marking and ANSI/IEEE Std C12.20 (0.2% accuracy) along with IEC 687 compliance, ensuring regulatory alignment and measurement reliability. With ModbusRTU and BACnet MSTP communications and a rugged NEMA 12 enclosure, it delivers fast integration and durable operation, even in demanding environments. By consolidating metering for up to three circuits in one enclosure, it supports proactive energy management, faster fault detection, and lower total cost of ownership for manufacturing, facilities, and data-center projects.

Product Information

Extended Description

PXM350MA6121-2A3A Eaton: Eaton enclosed meter, NEMA12(120/240V, No CPT), 1-3PH/4W Main Fused Disconnect, CT Terminal Block per PXM, Control Power Fused Disconnect per PXM
Product Name
Eaton enclosed meter
Catalog Number
PXM350MA6121-2A3A
UPC
786689718725
Product Length/Depth
12 in
Product Height
30 in
Product Width
20 in
Product Weight
100 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
120/240V
Power supply
120/240 Vac
Enclosure
NEMA 12
Enclosure size
30inH x 20inW x 8inD
Number of meters
3
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
ModbusRTU,BACnet MSTP
NEMA 12 enclosure provides rugged protection against dust and humidity, reducing maintenance and extending meter life in harsh industrial spaces. This protection translates to improved reliability and fewer field service interruptions in electrical rooms and on factory floors. The PXM350MA6121-2A3A incorporates a CT terminal block per PXM, a 1-3PH/4W main fused disconnect, and a control power fused disconnect, enabling streamlined wiring and safe local control. The result is faster commissioning, reduced wiring errors, and easier compliance with electrical standards on new or retrofit installations. With three meters in one enclosure, you gain consolidated feed monitoring, simplified logistics, and lower hardware count for multi‑branch applications across production lines. ModbusRTU and BACnet MSTP interfaces enable straightforward integration into existing building management systems, delivering centralized energy visibility and actionable operating data. ANSI/IEEE C12.20 (0.2% accuracy) and IEC 687 (0.2% accuracy) certification underpin trusted measurement and regulatory compliance, reducing audit risk and service costs. The 30inH x 20inW x 8inD footprint and 100 lb weight support thoughtful space planning and mounting in standard electrical rooms, while the NEMA 12 enclosure protects equipment from dust and moisture during daily operations.

Get a Quick Quote for a Eaton PXM350MA6121-2A3A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXM350MA6121-2A3A? Enquire Now

FAQs

Installation uses a 120/240V supply with a 50/60 Hz rating and a 1-3 phase, 4‑wire configuration. The unit includes a CT terminal block per PXM and a main fused disconnect plus a control power fused disconnect, simplifying wiring integration. Mounting should be within a NEMA 12‑rated enclosure footprint (30inH x 20inW x 8inD) in a compliant electrical room with adequate space for access and cabling.
The PXM350MA6121-2A3A is certified to ANSI/IEEE Std C12.20 with 0.2% accuracy and IEC 687 also at 0.2% accuracy, plus CE marking for European compliance. These certifications provide confidence in measurement reliability, regulatory alignment, and suitability for utility-grade energy monitoring in industrial facilities.
Yes. The meter supports ModbusRTU and BACnet MSTP, enabling direct integration with common building management and industrial automation systems. This facilitates centralized energy monitoring, data aggregation, and real-time fault analysis without requiring additional adapters or custom firmware.
Expected ROI comes from improved energy visibility, reduced energy waste, and faster fault diagnosis. With three meters in one enclosure and centralized data access via standard protocols, facilities can identify usage anomalies, optimize peak demand, and lower energy costs, often offsetting installation requirements within months of deployment.
The enclosure measures 30 inches high by 20 inches wide by 8 inches deep and weighs about 100 pounds, with a NEMA 12 rating. This footprint fits typical electrical rooms and panel housings, enabling straightforward placement in existing spaces without major remodeling.