Eaton PXM350MA6541-2D8A Enclosed Meter - NEMA 12

Part Number: PXM350MA6541-2D8A
Eaton logo
Manufacturer
Eaton
Part number
PXM350MA6541-2D8A

Quick Summary

Eaton enclosed meter provides panel-mounted energy monitoring for 1–3 phase systems in industrial facilities. This compact solution addresses the challenge of adding metering without bloating control cabinets or increasing wiring complexity. The unit carries CE marking and ANSI/IEEE performance certifications, plus IEC 687, underscoring accuracy and reliability. With ModbusRTU and BACnet MSTP communications, it integrates smoothly with existing SCADA and BMS environments, while its eight meters support scalable energy monitoring across multiple circuits. In short, it delivers robust metering, easier installation, and better visibility for energy management and cost control.

Product Information

Extended Description

PXM350MA6541-2D8A Eaton: Eaton enclosed meter, NEMA12(120/240V, No CPT), 1-3PH/4W Main Fused Disconnect, Control Power Fuse Disconnect per PXM, CT Shorting Block per PXM
Product Name
Eaton enclosed meter
Catalog Number
PXM350MA6541-2D8A
UPC
786689718787
Product Length/Depth
12 in
Product Height
36 in
Product Width
30 in
Product Weight
100 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
240 V/480 V
Power supply
240 V/480 V
Enclosure
NEMA 12
Enclosure size
36inH x 30inW x 8inD
Number of meters
8
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
ModbusRTU,BACnet MSTP
Feature: Eight meters in a single enclosure with a dedicated CT Shorting Block. Business Impact: Centralizes multi-circuit energy data with reduced wiring and cabinet clutter, enabling faster commissioning and simpler maintenance. Application: Sub-panel energy monitoring in manufacturing lines and data centers. Keywords: multi-circuit metering, energy data centralization, eight-channel meter, CT shorting block. Feature: 240 V/480 V voltage rating. Business Impact: Supports common industrial distribution without custom transformers or adapts, lowering implementation risk. Application: Panel upgrades and new installations in machine rooms and process systems. Keywords: 240/480 V, industrial power distribution, panel integration. Feature: NEMA 12 enclosure. Business Impact: Protects electronics from dust and incidental moisture, extending service life in indoor environments and control cabinets. Application: Retrofits inside manufacturing cells and assembly lines. Keywords: NEMA 12 enclosure, industrial enclosures, cabinet protection. Feature: Communications ModbusRTU and BACnet MSTP. Business Impact: Seamless integration with SCADA/BMS for real-time monitoring and centralized data analytics. Application: Energy management, facility automation, and demand response projects. Keywords: ModbusRTU, BACnet MSTP, building automation. Feature: Certifications and accuracy (CE marked; ANSI/IEEE C12.20, C62.41; IEC 687 0.2% accuracy). Business Impact: Ensures regulatory compliance and measurement precision for audits and asset management. Application: Procurement specifications and compliance documentation. Keywords: CE marked, ANSI/IEEE C12.20, IEC 687, 0.2% accuracy. Feature: Display and physical dimensions (Meter Faceplate; 12 in L, 36 in H, 30 in W; 100 lb). Business Impact: Local visibility with compact footprint-to-performance ratio, simplifying installation planning and space budgeting. Application: New builds and retrofits where space is at a premium. Keywords: meter faceplate, 36inH x 30inW x 8inD, 100 lb.

Get a Quick Quote for a Eaton PXM350MA6541-2D8A

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXM350MA6541-2D8A? Enquire Now

FAQs

Installation requires mounting the NEMA 12 enclosure within a controlled indoor space, routing conductors to the eight metering channels, and connecting the CT Shorting Block per the PXM reference. Plan for space to accommodate the 12 in L, 36 in H, and 30 in W footprint and ensure compatibility with 240/480 V feeders and a 50/60 Hz supply.
The meter exposes ModbusRTU and BACnet MSTP interfaces, enabling polling and data collection from energy counters across multiple circuits. Configure device addresses, baud rate, and network topology to integrate real-time kWh, kW, and other metrics into SCADA or EMS dashboards for centralized energy management and fault diagnosis.
Yes. The PXM350MA6541-2D8A supports 240 V/480 V operation, making it compatible with many industrial distribution schemes. This flexibility reduces the need for multiple metering solutions during panel upgrades and supports diverse plant architectures without extensive rewiring.
The unit is CE marked and carries ANSI/IEEE C12.20 (0.2% accuracy) and IEC 687 (0.2% accuracy) certifications, along with ANSI/IEEE C62.41. These specifications support regulatory compliance, precise energy measurement, and reliability in critical energy management applications.
By consolidating eight meters into one enclosure, installers reduce wiring complexity and cabinet space, lowering commissioning time and maintenance costs. The robust enclosure and standards-compliant performance translate to fewer field faults, improved data quality for energy analytics, and accelerated payback through better energy visibility and control.