Eaton PXMP-MM100MA Power Xpert Meter Module - UL Listed 61010-1

Part Number: PXMP-MM100MA
Manufacturer
Eaton
Part number
PXMP-MM100MA

Quick Summary

Power Xpert multi-point meter module is a scalable solution for submetering across multi-feeder systems. It enables energy visibility where traditional single-point meters fall short, reducing guesswork and enabling data-driven decisions.UL Listed 61010-1 and CE Marked certifications provide safety and regulatory confidence, while ANSI/IEEE C12.20 with 0.5% accuracy underpins reliable reporting. This module, designed to work with PXMP-MB, unlocks per-phase insights and data logging without adding excessive installation complexity, delivering measurable business value in both cost reduction and compliance. With its flexible I/O and compact form, it supports integrating energy data into existing Power Xpert interfaces and building management systems for better operational efficiency.

Product Information

Extended Description

PXMP-MM100MA Eaton: Eaton Power Xpert Multi-Point Meter, Module, External power source, 100 mA, CT secondary, 14.6 ohms, used with PXMP-MB, PXMP-MM100MA
Product Name
Eaton Power Xpert multi point Meter module
Catalog Number
PXMP-MM100MA
UPC
786685757896
Product Length/Depth
11 in
Product Height
1 in
Product Width
2.9 in
Product Weight
0.3 lb
Warranty
1 year
Compliances
CE Marked
Certifications
UL Listed 61010-1 File E185559 CSA Std. C22.2 No. 1010.1.92 ANSI/IEEE Std C12.20 (0.5% accuracy)
Catalog Notes
20% over-range see sensor for primary isolation
Used with
PXMP-MB, PXMP-MM100MA
Type
Module
Memory
None
%Thd - current and voltage
None
Individual harmonics magnitude
None
Waveform capture sampling rate
None
Impulse transient capture
None
ANSI % revenue accuracy
C12.20 (0.5)
Current sensor input
100 mA
Instrumentation
Watt Demand Demand Metering Per Phase Power Factor Va demand Watts Current & Voltage - Per Phase
Logging
Data Logging
I/O capability
Analog Input/Output Prog. Pulse Output --Wh, Varh, Vah Digital Input/Output
Model
External power source
Feature: 100 mA current sensor input with CT secondary and 14.6 ohms. Business Impact: Delivers precise, scalable submetering without bulky external transducers. Application: Ideal for multi-point energy monitoring in switchgear and panel boards. Feature: Data logging and per-phase instrumentation. Business Impact: Enables traceable energy analytics, regulatory reporting, and rapid fault isolation. Application: Useful in commercial facilities and light industry requiring per-phase Watt Demand, VA demand, and Power Factor data. Feature: Analog Input/Output and programmable pulse output for Wh, Varh, Vah. Business Impact: Supports integrated monitoring plus control signals, reducing external wiring and interfaces. Application: Supports energy management, demand response, and feeds into PM systems. Feature: Certifications and safety conformance. Business Impact: Ensures regulatory compliance, safer installations, and reliable data quality. Application: Suitable for global deployment in electrical rooms, switchgear, and distribution panels. Feature: Compatibility with PXMP-MB and PXMP-MM100MA modules. Business Impact: Accelerates deployment, simplifies spare-part inventory, and enables future expansion. Application: Retrofit projects and new builds needing modular, standards-based metering.

Get a Quick Quote for a Eaton PXMP-MM100MA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXMP-MM100MA? Enquire Now

FAQs

To install PXMP-MM100MA with a PXMP-MB base, mount the module in the Power Xpert cabinet or panel per the enclosure guidelines and connect the 100 mA current sensor input with the CT secondary. Observe the 20% over-range guidance for primary isolation and verify CE/UL compliance. Route and label signals for per-phase metering and ensure proper grounding and safety clearances.
PXMP-MM100MA delivers ANSI/IEEE C12.20 accuracy at 0.5%, with a 100 mA current sensor input and CT secondary. It supports per-phase Watts, VA, and Power Factor measurements, along with Watt Demand and Va demand. The device includes data logging and I/O for integrated measurements, providing reliable energy data for regulatory reporting and energy-management initiatives.
Yes. The module provides per-phase metering, data logging, and programmable outputs that integrate with Power Xpert interfaces. Its scalable design fits multi-point submetering in data centers, manufacturing, and commercial facilities, enabling accurate energy analytics, improved efficiency, and faster fault detection while maintaining compliance with relevant standards.
PXMP-MM100MA is UL Listed 61010-1 and CE Marked, with additional conformity under CSA standards and ANSI/IEEE C12.20 (0.5% accuracy). These certifications support safe installation in electrical environments and compliant energy reporting across global markets, reducing risk during audits and inspections.
The module delivers enhanced energy visibility through per-point measurements and data logging, enabling precise consumption analytics and regulatory reporting. Its modular design reduces upfront costs, accelerates deployment, and supports future expansion, delivering a faster ROI through reduced energy waste, improved maintenance planning, and easier integration with existing energy-management ecosystems.