Eaton PXMP-PIM Power Xpert Meter Input Module - UL Listed

Part Number: PXMP-PIM
Manufacturer
Eaton
Part number
PXMP-PIM

Quick Summary

Eaton PXMP-PIM is a Power Xpert multi point meter input module for pulse input monitoring in distributed systems. Engineers often grapple with secure pulse input isolation, external power sourcing, and reliable data logging in harsh industrial environments. This device is CE marked, UL listed and CSA certified, aligning with global safety standards and facilitating field acceptance. By delivering precise metering data and flexible power options, it supports scalable energy management, compliance reporting, and informed decision making across plants. Its compatibility with PXMP-MB and related components ensures straightforward installation in existing Power Xpert networks.

Product Information

Extended Description

PXMP-PIM Eaton: Eaton Power Xpert multi point meter input module, Pulse Input Module, External power source, 0.01A, 24 +/- 20% Vdc, Pulse input, 300V to ground isolation, 2.22K ohms, used with PXMP-MB, PXMP-MB-AB, PXMP-PIM
Product Name
Eaton Power Xpert multi point meter input module
Catalog Number
PXMP-PIM
UPC
786685757940
Product Length/Depth
11 in
Product Height
1 in
Product Width
2.9 in
Product Weight
0.3 lb
Warranty
1 year
Compliances
CE Marked
Certifications
UL Listed 61010-1 File E185559 CSA Std. C22.2 No. 1010.1.92
Catalog Notes
TVS Diode Clamped, Note: opto creates 2.2 V drop sourced by 2.2 Kohms. Isolation dependent on external source. To PE. Group Isolated, All Circuits Common to 24 V Ext. Source.
Used with
PXMP-MB, PXMP-MB-AB, PXMP-PIM
Type
Pulse Input Module
Voltage rating
24 +/- 20% Vdc
Memory
None
%Thd - current and voltage
None
Individual harmonics magnitude
None
Waveform capture sampling rate
None
Impulse transient capture
None
ANSI % revenue accuracy
C12.20 (0.5)
Current sensor input
10 mA
Logging
Data Logging
I/O capability
Prog. Pulse Output --Wh, Varh, Vah
Model
External power source
Feature: Pulse input module with 0.01 A sensitivity and 24 +/- 20% Vdc supply. Benefit: Enables precise capture of external pulse signals, improving accuracy in energy submetering and reporting. Application: Ideal for panel-level monitoring in manufacturing lines where accurateWh, Vah, and Varh data is required. Feature: 300 V to ground isolation. Benefit: Reduces ground loop risks and enhances safety in shared enclosures, supporting compliant operation in mixed electrical environments. Application: Utility rooms and control panels with multiple power sources benefit from reliable isolation. Feature: Programmable Pulse Output for Wh, Varh, Vah. Benefit: Seamless integration with downstream analytics and metering dashboards, accelerating reporting and billing accuracy. Application: Submetering in energy management systems across plants and campuses. Feature: External power source operation. Benefit: Flexible installation without relying on the measurement network power, enabling remote or decentralized deployments. Application: Remote substations and panels where independent power is preferred. Feature: Data Logging and Compatibility. Benefit: Creates an auditable trail for compliance and performance reviews, reducing fault investigation time. Application: Industrial facilities implementing Eaton Power Xpert multi-point meters and PXMP-PIM across multiple lines. Feature: Compliance and Certifications. Benefit: Lowers procurement risk with CE, UL, and CSA certifications supporting global deployments. Application: Global manufacturing sites and regulated industries require proven safety and interoperability.

Get a Quick Quote for a Eaton PXMP-PIM

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXMP-PIM? Enquire Now

FAQs

To install PXMP-PIM with PXMP-MB, mount the module in a standard enclosure, connect the external 24 VDC power source, and wire the pulse input lines to the designated terminals. Ensure the 300 V isolation path is maintained and verify proper grounding. Finally, configure the device in the Configuration Tool to enable data logging and the Wh, Varh, Vah outputs.
PXMP-PIM uses a 24 +/- 20% Vdc supply, accepts a 10 mA current sensor input, and features 0.01 A pulse sensitivity with a 2.22 kΩ input impedance. It provides 300 V isolation to ground and supports data logging with programmable pulse outputs for Wh, Varh, and Vah, enabling precise energy measurement.
Yes. PXMP-PIM is CE marked, UL Listed 61010-1 (File E185559), and CSA certified (C22.2 No. 1010.1.92), ensuring compliance with international safety and performance standards for electrical measurement equipment used in regulated environments.
The module is ideal for multi-point pulse metering and energy submetering in switchgear and control panels. It integrates with Power Xpert meters to deliver accurate Wh, Varh, and Vah data, supports external power sources, and helps facilities monitor energy use, optimize consumption, and support regulatory reporting.
With built-in data logging and reliable isolation, PXMP-PIM reduces fault investigation time and improves energy visibility, contributing to faster compliance reporting and reduced energy waste. A standard 1-year warranty adds assurance, and its compatibility with PXMP-MB components minimizes spare parts and maintenance costs.