Eaton Enclosed Meter PXMP1300MA15-2D-DCE - ANSI/IEEE C12.20
Part Number: PXMP1300MA15-2D-DCE
Quick Summary
Eaton Enclosed Meter PXMP1300MA15-2D-DCE is a robust energy metering solution designed for industrial panels and machine rooms. It consolidates two meters in a single enclosure, delivering integrated readings with a 6-inch touch display for quick on-site visibility. Operators often struggle with wiring complexity, data silos, and slow commissioning when upgrading legacy meters; this unit simplifies deployment with Modbus TCP/WEB Push Modbus, RS-485 Modbus, and a built-in 4-port Ethernet switch. With NEMA 12 protection and compatibility for 600 V systems, it supports CE marking and ANSI/IEEE C12.20 (0.2% accuracy) alongside IEC 687 (0.2% accuracy), ensuring compliance and reliability. The business value is clear: faster setup, better energy visibility, and scalable metering that supports energy management initiatives and predictive maintenance.
Product Information
Extended Description
PXMP1300MA15-2D-DCE Eaton: Eaton enclosed meter, (1) PXMP-MB (PXMP-EPM included) with 6IN display (1) PXM1300 (Integrated display, 415 Vac/300 Vdc Power Supply, 5 A Input) with Modbus TCP/WEB Push Modbus, 4-port ethernet switch, PXG900, NEMA 12, 600 VCPT
Product Name
Eaton enclosed meter
Catalog Number
PXMP1300MA15-2D-DCE
UPC
786689281748
Product Length/Depth
30 in
Product Height
36 in
Product Width
10 in
Product Weight
200 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
600V
Power supply
120-240VAC
Enclosure
NEMA 12
Enclosure size
36x30x10
Number of meters
2
Display
6" Touch Screen
Frequency rating
50/60 Hz
Communication
RS-485 Modbus
Degree of protection
NEMA 12
Eaton's enclosed meter family
Eaton's enclosed meter family
Eaton's Enclosed Meters
Eaton Specification Sheet - PXMP1300MA15-2D-DCE
Feature: Dual-meter architecture in one rugged enclosure. Business Impact: Reduces installation footprint, minimizes wiring complexity, and consolidates data streams for central energy management. Application: Industrial panels and switchgear cabinets requiring consolidated metering without multiple boxes. Long-tail keywords: industrial energy management, two-meter enclosure, scalable metering. Feature: 6-inch touch screen display options. Business Impact: Improves on-site visibility and reduces commissioning time, enabling faster decision-making. Application: Real-time monitoring at the machine floor and control panels. Long-tail keywords: 6 inch display, on-site readability, operator interface. Feature: Modbus TCP/WEB Push Modbus and RS-485 Modbus communications. Business Impact: Simplifies integration with existing SCADA/MES and enables reliable data exchange for analytics. Application: Factory floor energy data collection and remote monitoring. Long-tail keywords: Modbus TCP, RS-485 Modbus, data integration. Feature: Built-in PXG900 4-port Ethernet switch. Business Impact: Helps create a reliable industrial network topology, reduces external networking hardware, and improves fault tolerance. Application: Local networks and remote diagnostics. Long-tail keywords: industrial networking, Ethernet switch, network reliability. Feature: NEMA 12 enclosure with 600 V rating and CE marking. Business Impact: Provides robust indoor protection, compatibility with high-voltage systems, and global compliance for safety and reliability. Application: Harsh factory environments and regulated facilities. Long-tail keywords: NEMA 12, CE Marked, high-voltage metering. Feature: Integrated PXM1300 display options and dual meters. Business Impact: Streamlines meter commissioning and allows direct visualization of two measurement channels for energy analytics. Application: Energy management and machine-level monitoring in manufacturing. Long-tail keywords: two-meter energy monitoring, inline visualization. Feature: 120-240 VAC power supply and 36x30x10 enclosure footprint. Business Impact: Flexible power sourcing and easier integration into existing electrical cabinets. Application: Retrofit projects and new installations with mixed voltages. Long-tail keywords: 120-240 VAC, enclosure size, retrofit metering.
Get a Quick Quote for a Eaton PXMP1300MA15-2D-DCE
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton PXMP1300MA15-2D-DCE?
Enquire Now
FAQs
Install the PXMP1300MA15-2D-DCE inside a 36x30x10 in NEMA 12 enclosure, securing it to a suitable mounting surface. Connect the 120-240 VAC supply and wire the two metering channels for voltage and current inputs. Route RS-485 Modbus and configure Modbus TCP/WEB for network access, then enable the 4-port Ethernet switch to integrate with the plant network. Ensure proper grounding and verify CE/ANSI certifications post-install.
The PXMP1300MA15-2D-DCE meets ANSI/IEEE Std C12.20 and IEC 687 with 0.2% accuracy and ANSI/IEEE Std C62.41 for surge considerations. It supports 50/60 Hz operation, a 600V voltage rating, and a 6 inch touch display for visualization. With two meters in one enclosure, it provides precise, dual-channel energy data suitable for detailed energy management and reporting.
Yes. The dual-meter enclosure, 6 inch touch display, Modbus connectivity, and built-in Ethernet switch enable real-time energy visibility across lines. The device integrates with SCADA/MES systems via RS-485 Modbus and Modbus TCP, supporting data analytics, efficiency tracking, and maintenance planning within an industrial energy management program.
The unit carries CE marking and ANSI/IEEE Std C12.20 (0.2% accuracy) along with IEC 687 (0.2% accuracy) and ANSI/IEEE Std C62.41. These certifications ensure regulatory compliance, reliability in demanding environments, and suitability for installation in regulated facilities.
You’ll experience reduced downtime and faster commissioning thanks to a single, integrated enclosure and an intuitive 6 inch display. The Modbus connectivity simplifies data collection for analytics, enabling better demand management and fault detection. The durable NEMA 12 enclosure and robust networking also lower field service costs over the asset life.