Eaton enclosed meter PXMP1300MA15-2D-DEJ - 0.2% IEC 687

Part Number: PXMP1300MA15-2D-DEJ
Manufacturer
Eaton
Part number
PXMP1300MA15-2D-DEJ

Quick Summary

Eaton enclosed meter PXMP1300MA15-2D-DEJ provides integrated power measurement for industrial control panels and electrical rooms. This compact, dual-meter system addresses the challenge of fragmented metering by consolidating monitoring in a single cabinet. Backed by CE marking and industry standards such as ANSI/IEEE C12.20 (0.2% accuracy) and IEC 687 (0.2%), it delivers reliable performance with proven compliance. By combining a 6-inch touchscreen display and Ethernet Modbus connectivity, it enables fast data access and scalable integration, supporting both local visibility and remote monitoring in modern automation environments.

Product Information

Extended Description

PXMP1300MA15-2D-DEJ Eaton: Eaton enclosed meter, (1)PXMP-MB (ABCN Voltage Inputs, EPM), PXMP 6in display, (1) PXM1300MA(Int Dsp,415Vac/300Vdc PS, 5 A IN, ModTCP), (1) 4-Port Eth SW,NEMA12, CPT(480Vac),DCPS MB/Disp/EthSw, (3) NEMA12 Door Ports-(1) USB to MB USB
Product Name
Eaton enclosed meter
Catalog Number
PXMP1300MA15-2D-DEJ
UPC
786689323134
Product Length/Depth
10 in
Product Height
36 in
Product Width
24 in
Product Weight
200 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
480V
Power supply
120-240VAC
Enclosure
NEMA 12
Enclosure size
36”H x 24”W x 10”D
Number of meters
2
Display
6" Touch Screen
Frequency rating
50/60 Hz
Communication
Ethernet Modbus
Degree of protection
NEMA 12
The PXMP1300MA15-2D-DEJ integrates two meters in a single NEMA 12 enclosure, delivering comprehensive energy data from a single source. This consolidation reduces wiring complexity and installation time while improving data accuracy, enabling more efficient energy management and asset utilization in manufacturing facilities. The 6-inch touch screen provides intuitive local visibility, speeding commissioning and on-site troubleshooting, which lowers maintenance overhead and improves operator efficiency. Built-in Ethernet Modbus communication and a 4-port Ethernet switch simplify SCADA and MES integration, enabling seamless data flow to centralized dashboards and remote monitoring platforms. The rugged NEMA 12 enclosure, coupled with a 36 x 24 x 10 inch footprint and a 200 lb cabinet weight, ensures reliable operation in demanding plant environments with dust and moisture exposure. With 480V rating and a 120-240VAC power supply, this meter covers typical industrial power rails, reducing the need for multiple devices. The system’s compliance heritage—CE Marked and ANSI/IEEE C12.20 (0.2% accuracy) along with IEC 687 (0.2% accuracy)—reduces audit risk and supports regulatory reporting, while USB MB connectivity facilitates field updates and maintenance. By supporting two meters, this solution is ideal for panel-level monitoring of multi-source loads, enabling precise accounting for energy usage and demand charges with minimal footprint and total cost of ownership.

Get a Quick Quote for a Eaton PXMP1300MA15-2D-DEJ

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXMP1300MA15-2D-DEJ? Enquire Now

FAQs

How does the PXMP1300MA15-2D-DEJ fit into established Modbus TCP networks? It supports Ethernet Modbus TCP and includes a built-in 4-port Ethernet switch, enabling straightforward integration with SCADA and EMS platforms. The two-meter configuration provides consolidated data channels, reducing wiring and simplifying panel design while preserving compatibility with common industrial switches and IP infrastructure.
This Eaton enclosed meter carries CE Marking and ANSI/IEEE Std C12.20 with 0.2% accuracy, plus IEC 687 at 0.2% accuracy. These certifications guarantee reliable energy measurement within tight tolerances, suitable for regulatory reporting and metering audits. The dual-meter arrangement maintains data integrity across inputs, which is critical for billing and process optimization.
The dual-meter enclosed system is ideal for control panels, machine rooms, electrical rooms, and data centers where precise monitoring of two separate feeders or loads is required. Its NEMA 12 enclosure and 480V rating make it suitable for harsh industrial environments, while the 6-inch touchscreen supports local verification and quick commissioning.
The meter complies with CE Marking, ANSI/IEEE C12.20 and C62.41 family references, and IEC 687, ensuring accurate measurements and reliability in industrial settings. Its NEMA 12 enclosure provides dust and moisture protection appropriate for indoor plant environments, and its 50/60 Hz compatibility aligns with global utility and facility power systems.
Consolidating two meters into one enclosure reduces hardware and wiring costs while improving energy visibility for charge-back and efficiency programs. The USB to MB interface simplifies field updates, and Ethernet connectivity enables remote monitoring and predictive maintenance. Over time, this reduces downtime, streamlines audits, and supports faster fault isolation and reporting.