Quick Summary

Eaton enclosed meter provides accurate three-phase, four-wire power metering for industrial panels and switchgear. Space constraints and integration with building management systems can slow projects and inflate commissioning costs. This CE-marked instrument meets ANSI/IEEE C12.20 and IEC 687 (0.2% accuracy) performance standards. With BACnet/IP, ModbusTCP, and WebUI, it simplifies configuration, data access, and cross-vendor interoperability across facilities. The robust NEMA 12 enclosure and dual-meter capability support scalable, maintenance-friendly deployments in demanding industrial environments. By consolidating two meters in a single enclosure, it reduces footprint and accelerates deployment within existing 480V infrastructure.

Product Information

Extended Description

PXMP3000MA15-2D-DEJ Eaton: PXMPMB(w/EPM),PXMP6inHMI-XV,PXM3k(IntgrlDisp,V/dc PS,5A In,MRTU,MTCP,BACnet/IP),NEMA12,CPT(480V),3PH/4W Main Volt Disc,4-PrtEthSw,VdcPS:HMIandETH SW,eaPXM CAT5 to E-SW,CTSB,3-NEMA12 Door Ports(1-USB,2-RJ45):USB to MB,RJ45 to E-SW
Product Name
Eaton enclosed meter
Catalog Number
PXMP3000MA15-2D-DEJ
UPC
786689362812
Product Length/Depth
10 in
Product Height
36 in
Product Width
24 in
Product Weight
100 lb
Compliances
CE Marked
Certifications
ANSI/IEEE Std C12.20 (0.2% accuracy) ANSI/IEEE Std C62.41 IEC 687 (0.2% accuracy)
Voltage rating
480V
Power supply
480 Vac
Enclosure
NEMA 12
Enclosure size
36inH x 24inW x 10inD
Number of meters
2
Display
Meter Faceplate
Frequency rating
50/60 Hz
Communication
BACnet/IP WebUI ModbusTCP ModbusRTU
Degree of protection
NEMA 12
Dual-meter enclosure delivers two meters in one chassis. This design reduces hardware footprint, simplifies wiring, lowers installation time, and minimizes ongoing maintenance costs in busy industrial panels. Applications include multi-circuit upgrades in manufacturing lines and data centers where space is at a premium and reliability is critical. Integrated communications and WebUI provide BACnet/IP, ModbusTCP, and ModbusRTU support along with a web-based configuration interface. Business impact includes centralized monitoring, faster commissioning, and improved data integrity, enabling facilities teams to orchestrate energy management across multiple systems with fewer integration points. Applications span facilities with building automation, SCADA, and centralized energy dashboards. Power specifications deliver 480V main supply in a 3PH/4W configuration, matching common industrial feeders. This compatibility minimizes the need for transformers or rewiring, accelerating project timelines and reducing total installed cost in manufacturing plants and processing facilities. Rugged NEMA 12 enclosure and a compact footprint (36inH x 24inW x 10inD) deliver durable operation in factory floors, dusty environments, and space-constrained rooms. This design supports long service life with reduced downtime and simplified serviceability. Applications include heavy industry, food & beverage facilities, and data centers where reliability matters. Certifications and accuracy milestones are captured by ANSI/IEEE C12.20 at 0.2% and IEC 687 performance levels, alongside CE marking. This combination ensures regulatory compliance, audit readiness, and dependable metering results in regulated environments. Applications span any compliant facility requiring precise energy data. Connectivity options such as USB, RJ45 ports, and Cat5 to E-SW support HMI integration and field configuration, simplifying installation and ongoing maintenance. The modular approach reduces commissioning time and enhances future-ready scalability for growing plants and digitalized operations.

Get a Quick Quote for a Eaton PXMP3000MA15-2D-DEJ

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton PXMP3000MA15-2D-DEJ? Enquire Now

FAQs

The PXMP3000MA15-2D-DEJ is designed for 480 Vac 3P/4W service and mounts in a NEMA 12 enclosure. Install the two meters side by side, connect the 480V supply and two monitored circuits, then wire the USB and RJ45 ports as needed. Use the WebUI or BACnet/IP for initial configuration and validation; ensure all connections meet local codes.
This meter supports BACnet/IP, ModbusTCP, ModbusRTU, and a WebUI for local/configuration access. Configure BACnet/IP via the WebUI network settings page, assign a device instance, and map their points to your building management or SCADA system. RJ45 ports facilitate E-SW connections, and Cat5 cabling simplifies network integration.
Yes. The enclosure accommodates two meters in a single footprint, saving space and wiring while enabling centralized energy monitoring for redundant or separately fed loads. With BACnet/IP and Modbus, you can integrate both meters into a single data center energy dashboard, improving visibility and control over critical circuits.
The meter is CE marked and meets ANSI/IEEE C12.20 (0.2% accuracy) and IEC 687, plus ANSI/IEEE C62.41 transient considerations. These certifications ensure regulatory compliance, accuracy, and reliability for metering in regulated facilities, simplifying audits and supporting dependable energy data for optimization programs.
ROI derives from reduced installation time and wiring complexity due to the dual-meter design, lower space requirements, and simplified integration with BACnet/IP and Modbus systems. Improved energy visibility enables rate optimization, predictive maintenance, and faster fault diagnosis, delivering measurable energy savings and tighter operational control across the facility.