Eaton enclosed meter PXQ-ST1-1A1-2B-D6 - NEMA 12, 480V
Part Number: PXQ-ST1-1A1-2B-D6
Quick Summary
Eaton enclosed meter delivers accurate power measurement for panel-level monitoring in industrial environments. Users often contend with hard-to-read displays and fragmented energy data that slow action. This model provides a robust NEMA 12 enclosure and 480V, 50/60 Hz operation; verify CE/UL compliance with the manufacturer. Together, these features support faster regulatory reporting, safer installations, and improved energy management across facilities. In practice, this enables engineers to capture real-time demand, monitor voltages, and compare against baselines for continuous improvement. Secondary benefits include straightforward integration with energy dashboards and maintenance workflows, reducing panel downtime and the cost of data reconciliation. Industry-ready, field-tested, and configurable.
Product Information
Extended Description
PXQ-ST1-1A1-2B-D6 Eaton: PXQ-ST1(1A1-N),NEMA12(480V),PXDB-HMI07,3PH/4W Main Fuse Disconnect,CT Shorting Block,Vdc Power Supply:PXQ&HMI
Product Name
Eaton enclosed meter
Catalog Number
PXQ-ST1-1A1-2B-D6
UPC
786689828318
Product Length/Depth
20 in
Product Height
12 in
Product Width
24 in
Product Weight
100 lb
Compliances
Contact Manufacturer
Voltage rating
480V
Power supply
480V
Enclosure
NEMA 12
Enclosure size
24inH x 20inW x 12inD
Number of meters
1
Display
Yes
Frequency rating
50/60 Hz
Metering devices, protective relays, software and connectivity
Metering devices, protective relays, software and connectivity
Eaton's Enclosed Meters
The PXQ-ST1-1A1-2B-D6 uses a robust 480V rating inside a NEMA 12 enclosure, delivering dependable protection against dust and moisture in industrial cabinets. This combination reduces field failures and minimizes maintenance time by keeping critical meters shielded from harsh conditions. Applicability spans main distribution panels, motor control centers, and retrofit projects where plug-and-measure energy data is required. The built-in display provides real-time visibility of energy consumption at the panel level, enabling operators to spot abnormal loads quickly. In practice, this supports faster root-cause analysis during production fluctuations and reduces operator fatigue from manual meter readings. Use cases include plant-wide energy dashboards and daily energy reconciliation in manufacturing environments. Dimensions—24in H x 20in W x 12in D—and a 100 lb weight, support straightforward installation in standard electrical rooms. The enclosure size and form factor allow installation in restricted spaces without compromising accessibility to the meter display and connections. This is particularly valuable for retrofit projects where space is at a premium and downtime must be minimized. The PXQ-ST1-1A1-2B-D6 integrates a main fuse disconnect and CT shorting block for safe commissioning and accurate CT-based measurements. Three-phase, four-wire configurations are supported, simplifying wiring during new builds and upgrades. This reduces commissioning risk and ensures compliant lockout/tagout procedures while maintaining measurement integrity across the system. Compatibility with standard 480V power systems and 50/60 Hz operation means rapid deployment across diverse facilities—data centers, facilities, and manufacturing lines. The unit’s energy-monitoring capability complements existing ERP and MES integrations by delivering clean, timestamped data for reporting and continuous improvement initiatives. In short, this is an energy management solution that pays back through efficiency gains and safer operations.
Get a Quick Quote for a Eaton PXQ-ST1-1A1-2B-D6
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton PXQ-ST1-1A1-2B-D6?
Enquire Now
FAQs
Install the PXQ-ST1-1A1-2B-D6 in a standard electrical cabinet with a NEMA 12 rated enclosure. Ensure adequate clearance for the 24inH x 20inW x 12inD footprint and access to the 1-meter display. Wire per three-phase four-wire (3PH/4W) configurations, include the CT shorting block for safe commissioning, and follow lockout/tagout protocols during wiring and testing.
Key specs include a 480V voltage rating with a 480V power supply, 50/60 Hz frequency, NEMA 12 enclosure, 24inH x 20inW x 12inD dimensions, 100 lb weight, a single meter, and built-in display. It supports 3PH/4W configurations and integrates a CT shorting block for safe CT-based measurements.
Yes. The enclosed meter is designed for panel-level energy monitoring in 480V three-phase environments, with on-board display and a compact footprint suitable for cabinet integration. It supports real-time energy measurement, which complements data center energy dashboards and helps meet monitoring, reporting, and reliability objectives while minimizing downtime during installation.
Verify standard regulatory certifications with Eaton for your region, including CE/UL where applicable. While the product data lists enclosure protection (NEMA 12) and basic specifications, actual certification readiness should be confirmed with the manufacturer to ensure suitability for your facility’s electrical codes and safety requirements.
Deploying the PXQ enclosed meters improves energy visibility, reduces manual reads, and supports faster anomaly detection. The resulting improvements in energy efficiency, reduced downtime, and streamlined data reconciliation translate to lower operating costs and enhanced compliance reporting, delivering a tangible return on investment for facilities with multi-panel distributions.