Eaton R9000 CCL B-Line Gutter Cabinets 3R UL

Part Number: R9000 CCL
Eaton logo
Manufacturer
Eaton
Part number
R9000 CCL

Quick Summary

Eaton R9000 CCL is a 400 A three-phase bussed gutter and termination cabinet for industrial electrical distribution. It addresses common wiring clutter and mis-taps by providing a centralized termination point before bussed gutters. UL-listed and EUSERC-approved with a 3R enclosure rating support rugged service in both overhead and underground applications. Manufactured from galvanized steel with ANSI 61 gray paint and surface mounting, it accommodates #4 to 600 MCM line and load lugs for four wires in three-phase systems, delivering robust durability, easier field wiring, and predictable maintenance cycles for overhead and underground feeders. Ideal for data centers, manufacturing floors, and utility installations, it streamlines procurement with a standard 400 A three-phase capacity.

Product Information

Extended Description

R9000 CCL Eaton: Eaton B-Line series bussed gutter and termination cabinets, 400 A, 3R, Overhead and underground, ANSI 61 gray painted, 042 kAIC, #4 - 600 MCM, #4 - 600 MCM, Galvanized steel, Surface mount, 4 wires, 3 phase
Product Name
Eaton B-Line series bussed gutter and termination cabinets
Catalog Number
R9000 CCL
UPC
782051072006
Product Length/Depth
7 in
Product Height
44 in
Product Width
18 in
Product Weight
72.5 lb
Compliances
EUSERC Approved
Certifications
UL
Amperage Rating
400 A
Phase
Three-phase
Interrupt rating
42 kAIC
Material
Galvanized steel
Finish
ANSI 61 gray paint
Number of wires
4
Feed type
Overhead/underground
Mounting method
Surface
Line lug size
#4 - 600 MCM
Load lug size
#4-600 MCM
Special features
Used as a termination point before bussed gutters
Degree of protection
3R
Feature: The R9000 CCL provides a 400 A, three-phase service with a 42 kAIC interrupt rating. Business impact: It supports robust fault current handling in mid-range distribution networks, reducing nuisance trips and enabling fast isolation of faults. Application: Ideal for manufacturing floors and utility spaces where a reliable termination point precedes bussed gutters. Feature: Lug capacity supports large conductors with #4 - 600 MCM line and load lugs. Business impact: This minimizes field adapters, speeds up terminations, and improves connection reliability under heavy loads. Application: Directly terminates feeders to high-capacity cables, streamlining wiring runs alongside bussed gutters. Feature: Galvanized steel construction with ANSI 61 gray paint delivers durable, corrosion-resistant protection. Business impact: Extends service life in challenging environments and reduces repainting costs over time. Application: Suitable for indoor and outdoor installations across industrial facilities. Feature: Overhead/underground feed capability with surface-mount mounting. Business impact: Provides installation flexibility and reduces civil works for retrofits. Application: Use in overhead duct routes, mezzanines, or below-grade installations where a termination point is needed. Feature: UL-listed, EUSERC-approved, with 3R enclosure rating. Business impact: Ensures code compliance, utility acceptance, and reliable protection from dust, moisture, and impact. Application: Ideal for projects requiring utility-grade approvals and consistent field performance. Feature: Compact footprint with a 7 in depth, 18 in width, and 44 in height, weighing 72.5 lb. Business impact: Easier handling and installation with standard rigging, reducing installation time and site disruption. Application: Surface-mounted cabinets suit tight equipment rooms and retrofit scenarios.

Get a Quick Quote for a Eaton R9000 CCL

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton R9000 CCL? Enquire Now

FAQs

Installing the R9000 CCL requires planning for surface-mounted mounting in a compliant enclosure area. Use the 4-wire, three-phase configuration and connect line and load lugs sized #4 to 600 MCM to ensure proper current carrying capacity. Confirm overhead or underground feed routing, observe clearance for future expansion, and follow Eaton’s torque and termination guidelines to maintain UL and EUSERC compliance.
The cabinet’s 400 A, three-phase rating with 42 kAIC interrupt capability supports diverse feeder loads and fault protection. Its overhead/underground feed compatibility, surface mounting, and galvanized steel construction with ANSI 61 gray finish deliver durable service across facilities. The design integrates easily with bussed gutters and termination cabinets, reducing installation steps and speeding up project commissioning.
Yes, the R9000 CCL is UL listed and EUSERC approved, reflecting compliance with safety, reliability, and utility-specific requirements. These certifications mitigate procurement risk, simplify code approvals, and support utility interconnections. The 3R enclosure rating also provides protection against moisture and impact in mixed indoor/outdoor environments, enabling broader deployment with confidence.
Ideal for manufacturing plants, distribution centers, and utility substations where a termination point precedes bussed gutters, the R9000 CCL handles four wires in three-phase service. It accommodates overhead and underground feeds with #4–600 MCM lugs, supports a 400 A load, and simplifies fault current paths while enabling clean, code-compliant wiring layouts.
With galvanized steel construction and ANSI 61 gray paint, the cabinet resists corrosion in typical industrial environments, reducing repaint and replacement costs. Regular inspections should verify lug terminations, enclosure seals for 3R protection, and cleanliness to prevent heat buildup. OEM catalogs and datasheets provide torque specs and replacement parts, supporting long-term reliability and predictable total cost of ownership.