Eaton R9000 F Bussed Gutter & Term Cabinets - UL Listed
Part Number: R9000 F
Quick Summary
The Eaton R9000 F bussed gutter termination cabinets deliver compact, high-current distribution for underground power feeds. Engineers often struggle with space constraints, corrosion risk, and complex wiring when upgrading large feeders in tight rooms and outdoor areas. These enclosures are UL-listed, EUSERC approved, and finished in ANSI 61 gray for durable outdoor service, providing peace of mind for code compliance and long-term reliability. Designed for retrofit and new installs, they support surface mounting, underground feeds, and flexible 3-wire configurations, helping shorten installation times while reducing total cost of ownership through robust materials and proven performance.
Product Information
Extended Description
R9000 F Eaton: Eaton B-Line series bussed gutter and termination cabinets, 1200 A, 3R, Underground, ANSI 61 gray painted, 065 kAIC, 6 Studs / Ø, (4) #4 - 600 MCM, Galvanized steel, Surface mount, 3 wires, 1 phase or 3 phase
Product Name
Eaton B-Line series bussed gutter and termination cabinets
Catalog Number
R9000 F
UPC
782051531886
Product Length/Depth
11 in
Product Height
52 in
Product Width
24 in
Product Weight
146 lb
Compliances
EUSERC Approved
Certifications
UL
Amperage Rating
1200 A
Phase
Single-phase, three-phase
Interrupt rating
65 kAIC
Material
Galvanized steel
Finish
ANSI 61 gray paint
Number of wires
3
Feed type
Underground
Mounting method
Surface
Line lug size
6 studs/Ø
Load lug size
(4) #4 - 600 MCM
Special features
Used as a termination point before bussed gutters
Degree of protection
3R
Feature: High current capacity and interrupt rating — 1200 A with 65 kAIC protection. Business Impact: Enables bulk feeder connections without multiple cabinets, reducing space needs and simplifying shutdowns for maintenance. Application: Underground or surface-mounted distributions serving large equipment loads in industrial facilities. Feature: Durable galvanized steel construction with ANSI 61 gray paint — corrosion resistance and long service life. Business Impact: Lower maintenance costs and fewer repaint/repair cycles in harsh environments. Application: Outdoor substations, industrial yards, and wet/damp indoor areas. Feature: UL listed and EUSERC approved Enclosure with 3R rating — compliance and safety assurance. Business Impact: Meets mandatory electrical standards, streamlines inspector approvals, and reduces project risk. Application: New builds and retrofit projects across manufacturing and process plants. Feature: Flexible wiring and lug configuration — 6 studs/Ø line lugs and (4) #4 - 600 MCM load lugs; supports 3-wire and 1/3-phase setups. Business Impact: Simplifies field terminations and accommodates diverse feeder designs, lowering install time and error rates. Application: Pre-bussed gutter terminations ahead of distribution gutters. Feature: Surface mounting with underground feed option — installation versatility and rapid deployability. Business Impact: Accelerates site readiness, minimizes floor space changes, and supports tight footprint layouts. Application: Retrofit projects and new installations in constrained spaces.
Get a Quick Quote for a Eaton R9000 F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton R9000 F?
Enquire Now
FAQs
The R9000 F supports surface mounting, with underground feed capability, making it suitable for retrofit and new installs in constrained spaces commonly found in manufacturing facilities.
Yes, the unit is UL-listed and EUSERC approved, with a 3R enclosure rating and an ANSI 61 gray finish that supports durable outdoor and indoor service in challenging environments.
The cabinet is rated for 1200 A with a 65 kAIC interrupt rating, enabling large feeders and multiple conductors to terminate safely before bussed gutters.
Ideal for underground power distribution and termination points ahead of bussed gutters in industrial plants, refineries, and utility-led installations needing reliable, high-current performance.
Its 6 stud/Ø line lugs, (4) 600 MCM load lugs, and surface-underground versatility reduce field terminations and wiring errors, leading to faster installs and lower maintenance costs over the life of the system.