Eaton RGHDC3300FFWM PV Guard - 125 kAIC, 600 Vac
Part Number: RGHDC3300FFWM
Quick Summary
Eaton PV Guard molded case circuit breaker protects solar PV systems against faults in utility-scale and commercial installations. Facility engineers struggle with reliable DC protection and fast trip coordination in PV arrays; this unit delivers fixed thermal/magnetic trip and high interrupt ratings. Note that certification details vary by region; consult Eaton PVGard datasheets for CE, SIL, and IP ratings where applicable. By aligning with PV system protection standards, this breaker reduces downtime and simplifies compliance, while offering robust performance in DC and AC protection. This translates to faster commissioning, easier maintenance planning, and lower total cost of ownership for solar projects. Engineers will appreciate consistent trip behavior across PV arrays and the rugged RG frame construction under harsh industrial conditions.
Product Information
Extended Description
RGHDC3300FFWM Eaton: Eaton Series G DC/PvGard complete molded case circuit breaker, RG-frame, RG, Fixed thermal, fixed magnetic trip, Three-pole, 3000A, 600 Vac, 250 Vdc, 125 kAIC at 240 Vac, 65 kAIC at 480 Vac, No terminals, Metric, Vdc, 50/60 Hz
Product Name
Eaton PV Guard / Solar complete molded case circuit breaker
Catalog Number
RGHDC3300FFWM
UPC
786685931937
Product Length/Depth
9.75 in
Product Height
15.5 in
Product Width
15.5 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Catalog Notes
INCLUDE (6) REAR CONNECTORS
Amperage Rating
3000A
Voltage rating
600 Vac, 250 Vdc
Trip Type
T186
Circuit breaker type
RG
Circuit breaker frame type
Complete breaker
Terminals
Without terminals
Class
Vdc
Interrupt rating
125 kAIC at 240 Vac 65 kAIC at 480 Vac
Number of poles
Three-pole
PVGard solar circuit breakers product aid
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
Value of Circuit Breakers for PV Systems and Eaton PVGard Solar Circuit Breakers
PVGard solar circuit breakers technical data sheet
PVGard solar circuit breakers technical data sheet
3000A amperage rating enables the breaker to handle large fault currents without nuisance trips, reducing unplanned outages in utility-scale PV farms. In practice, this translates to higher availability and smoother inverter protection coordination across multiple strings, supporting reliable grid integration in commercial and industrial installations. The rating also provides headroom for future capacity expansions within existing electrical rooms. 600 Vac / 250 Vdc voltage rating covers both AC and DC protection in PV systems, simplifying protection design and stocking. This dual rating allows a single device to protect the AC mains and the PV DC side, streamlining installation for rooftop arrays and large-scale solar plants alike. It reduces the number of different breakers needed on a typical PV protection panel. Fixed thermal/magnetic trip (T186) delivers predictable response and fast fault clearance, improving protection coordination with upstream devices. This minimizes nuisance trips during inrush or transient faults and supports safer maintenance windows in live PV installations. Operators benefit from consistent, repeatable performance across seasons and weather conditions. Three-pole RG frame provides synchronized protection across all three phases, with efficient mounting in common electrical enclosures. The RG design aligns with Eaton PVGard families, simplifying spare-part compatibility and field service. Installation teams gain time savings from standardized mounting patterns and documented wiring methods for PV protection circuits. Terminals are not included by default, but catalog notes indicate six rear connectors are included to speed field wiring. This configuration supports quick installation in tight spaces and reduces custom wiring work when integrating with PV inverters and switchgear. The result is faster commissioning and lower project risk. Interrupt ratings of 125 kAIC at 240 Vac and 65 kAIC at 480 Vac deliver robust fault interruption at common PV system voltages. Combined with DC protection at 250 Vdc and a T186 trip curve, the device provides dependable safety margins for both AC and DC portions of solar installations.
Get a Quick Quote for a Eaton RGHDC3300FFWM
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton RGHDC3300FFWM?
Enquire Now
FAQs
The RGHDC3300FFWM includes six rear connectors; terminals are not provided by default. This setup speeds field wiring, reduces custom fabrication, and supports a cleaner enclosure layout when wiring PV protection circuits. Compatible with the PVGard family, the connectors enable reliable, repeatable terminations for three-pole protection in commercial and utility-scale installations.
Key ratings include a 3000A amperage rating, 600 Vac and 250 Vdc voltage ratings, and interrupt ratings of 125 kAIC at 240 Vac and 65 kAIC at 480 Vac. It uses a fixed thermal/magnetic trip (T186) and is a three-pole RG frame molded case circuit breaker designed for PV protection in both AC and DC domains.
Yes. It protects PV systems by providing robust DC protection on the PV side (250 Vdc) and AC protection on the grid side (600 Vac), with high interrupt ratings for fault currents typical in solar installations. It is designed for use within the Eaton PVGard ecosystem and aligns with three-phase protection requirements.
Compliance details are provided by the manufacturer; this model lists 'Compliances: Contact Manufacturer.' For regional certifications such as CE, SIL, or IP ratings, consult Eaton's PVGard technical data sheets and local approvals. Verify compatibility with your project’s regulatory requirements before deployment.
Dimensions are 9.75 in length (depth), 15.5 in height, and 15.5 in width. Weight is listed at 0.001 lb. It is a three-pole RG frame unit, shipped without terminals, but rear connectors are included. Mounting in standard enclosures is straightforward, supporting efficient space utilization in PV protection assemblies.