Eaton RGHDCW3125WMA12 Molded Case Breaker - 65 kAIC
Part Number: RGHDCW3125WMA12
Quick Summary
Eaton RGHDCW3125WMA12 molded case circuit breaker protects critical DC power circuits in industrial automation and control panels. The design minimizes panel footprint and simplifies wiring, addressing common installation challenges in high-density enclosures. Certified UL Listed, IEC Rated, and CSA Certified, it meets rigorous safety and performance standards for global deployments. With a 1250 A rating and three-pole configuration, the device supports robust protection and easier coordination in DC power systems. Its Series G lineage and 65 kAIC interrupt capability at 600 Vdc, plus an auxiliary 2A-2B switch, streamline provisioning and regulatory compliance for demanding applications.
Product Information
Extended Description
RGHDCW3125WMA12 Eaton: Eaton series G RGHDC - frame molded case circuit breaker, 1250A, 600Vdc, with 2A/2B Auxiliary switch, 65 kAIC at 600Vdc, without terminals, electronic trip
Product Name
Eaton Series G molded case circuit breaker
Catalog Number
RGHDCW3125WMA12
UPC
786689028114
Product Length/Depth
19 in
Product Height
20 in
Product Width
18 in
Product Weight
125 lb
Certifications
UL Listed IEC Rated CSA Certified
Type
Series G
Amperage Rating
1250 A
Voltage rating
600 Vdc
Trip Type
T174
Auxiliary switch
2A-2B
Voltage - max
600V
Series
Series G
Terminals
Without terminals
Interrupt rating
65 kAIC at 600 Vdc
Number of poles
Three-pole
Trip rating
1250 A
Application of Multi-Wire Terminals for Molded Case Circuit Breakers
Application of Multi-Wire Terminals for Molded Case Circuit Breakers
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Motor protection circuit breakers product aid
Breaker service centers
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
NG and ND-Frame molded case circuit breakers
NG and ND-Frame molded case circuit breakers
NG and ND-Frame molded case circuit breakers
1250 A amperage rating enables the RGHDCW3125WMA12 to handle peak loads common in automation panels while preserving protection margins during startup. This high rating reduces the need for oversized protective devices, translating into cost savings and space efficiency in panels and switchgear. It is well suited for main feeders and critical DC distribution paths where uptime is essential.600 Vdc voltage rating provides DC-specific protection, addressing arcing and insulation challenges unique to DC systems. This rating supports safe interruption of fault currents and reliable coordination with downstream breakers in control cabinets, robotics systems, and conveyor drives.65 kAIC at 600 Vdc interrupt rating ensures the MCCB can safely interrupt large fault currents, protecting equipment and reducing panel stress. When used with compatible protection schemes, it enables selective coordination and minimizes downtime from faults in automated lines.Three-pole configuration with a 2A-2B auxiliary switch offers robust protection with local signaling for remote fault indication. Being specified without terminals lets you select compatible lug accessories and tailor conductor connections to your enclosure, while the 19 by 18 by 20 inch footprint fits standard 19-inch panels and avoids overhang.Certifications UL Listed, IEC Rated, and CSA Certified help ensure compliance with North American and international standards. This makes the Series G MCCB suitable for global deployments in industrial automation, manufacturing, and DC distribution networks, reducing procurement risk and accelerating project timelines.
Get a Quick Quote for a Eaton RGHDCW3125WMA12
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton RGHDCW3125WMA12?
Enquire Now
FAQs
Because the device is specified without terminals, plan for compatible lug accessories or terminal blocks suited to your enclosure and conductor gauge. Ensure mounting space respects the 19 in depth, 18 in width, and 20 in height footprint, and verify torque and connection guidelines per Eaton hardware. Prepare proper clearance for heat dissipation and optional signaling components.
Key specs include amperage rating of 1250 A, voltage rating of 600 Vdc, interrupt rating of 65 kAIC at 600 Vdc, three-pole configuration, trip type T174, and auxiliary switch 2A-2B. The unit is UL Listed, IEC Rated, and CSA Certified, and weighs about 125 lb with a 19 in depth, 18 in width, and 20 in height footprint.
Yes. The RGHDCW3125WMA12 Series G MCCB is designed for DC protection with a 600 Vdc rating and 65 kAIC interrupt capability, enabling reliable protection in control panels, automation equipment, and DC distribution networks. It supports compatible coordination with downstream devices and is certified for global deployment, aiding regulatory compliance.
This MCCB is UL Listed, IEC Rated, and CSA Certified. These certifications validate safety and performance to North American and international standards, facilitating procurement, audits, and multinational deployment in industries like manufacturing, material handling, and process automation.
The unit fits a 19-inch panel footprint with dimensions of 19 in depth, 18 in width, and 20 in height, and weighs approximately 125 lb. This information helps with cabinet space planning, rack alignment, and ensuring adequate support structure within enclosures.