Eaton RV48M28F4916PDSD Breaker-Integrated DOE2016

Part Number: RV48M28F4916PDSD
Manufacturer
Eaton
Part number
RV48M28F4916PDSD

Quick Summary

Eaton Breaker integrated ventilated transformer provides compact power conversion for industrial electrical systems. For engineers and procurement teams, space constraints and complex wiring often delay projects and escalate costs. The unit carries DOE2016 Efficient compliance and UL Listed certification, underscoring energy performance and safety. With built-in primary and secondary breakers and an aluminum enclosure, it simplifies installation and reduces total cost of ownership. This solution supports reliable power conditioning in demanding environments while aligning with maintenance strategies and uptime targets.

Product Information

Extended Description

RV48M28F4916PDSD Eaton: Eaton Breaker integrated ventilated transformer, 150 Kva, BRKR INTEG XFMR, 3PH, 480-208Y/120, 115C Rise, Aluminum, DOE 2016, Primary and secondary breakers
Product Name
Eaton Breaker integrated ventilated transformer
Catalog Number
RV48M28F4916PDSD
UPC
786689586874
Product Length/Depth
31.5 in
Product Height
59.52 in
Product Width
34.5 in
Product Weight
1405 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Frame
FR943DD
Feature: Breaker-integrated design reduces panel footprint and wiring complexity. Business Impact: Consolidates protection hardware, minimizes enclosure depth, lowers material and labor costs; enhances safety by reducing interconnect points. Application: Well-suited for retrofit and new-install projects in tight plant spaces, control cabinets, and machine rooms where accessibility is limited. Feature: 150 kVA rating in a 3-phase 480-208Y/120 V configuration. Business Impact: Supports critical loads with stable voltage transformation, reduces the number of transformers needed, and improves site reliability. Application: Power distribution for motors, machines, and process controllers in manufacturing, packaging, or material handling facilities. Feature: DOE2016 Efficient compliance. Business Impact: Delivers measurable energy savings, contributing to lower utility bills and green metrics across operations. Application: Continuous-process facilities and facilities seeking energy-performance certification. Feature: UL Listed certification. Business Impact: Ensures safety compliance and accelerates procurement by meeting industry standards. Application: Utilities, food & beverage, pharmaceutical, and data centers where safety approvals are mandatory. Feature: Aluminum enclosure frame FR943DD and robust construction. Business Impact: Corrosion resistance, durable service life in harsh environments, and easier handling during maintenance. Application: Outdoor or damp locations and corrosive environments common in mining, chemical plants, and heavy manufacturing. Feature: Primary and secondary breakers integrated in the unit. Business Impact: Reduces wiring complexity, simplifies maintenance, and shortens shutdown times for service. Application: Control panels and substations where rapid protection and simplified fault isolation are valued.

Get a Quick Quote for a Eaton RV48M28F4916PDSD

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton RV48M28F4916PDSD? Enquire Now

FAQs

RV48M28F4916PDSD is a 150 kVA, 3-phase transformer with integrated breakers designed for straightforward retrofit and new installations. Ensure mounting clearance for the 59.52 in height, 34.5 in width, and 31.5 in depth profile, confirm compatible enclosure mounting points, and plan feeder wiring for 480-208Y/120 V. Use standard conductor sizes and ensure alignment with UL-listed assembly instructions to maintain DOE2016 efficiency and safety.
The RV48M28F4916PDSD delivers up to 150 kVA with a 3-phase 480Y/208-120 V output. It provides efficient voltage conversion and integrated protection via primary and secondary breakers, reducing external components. This configuration supports motor drives, controls, and process equipment while maintaining stable voltage during load fluctuations typical in manufacturing environments.
Yes. The unit carries UL Listed certification for safety and meets DOE2016 Efficient compliance for energy performance. Its aluminum enclosure offers corrosion resistance suitable for harsh environments, while the integrated breakers simplify compliance documentation and installation workflows in regulated sectors such as utilities, food & beverage, and pharma.
The integrated primary and secondary breakers reduce external wiring, shorten fault isolation times, and simplify routine maintenance. Fewer components mean lower spare-part inventories and faster service interventions, which translates into reduced downtime and lower lifecycle costs. This design also lowers installation labor and reduces panel footprint in constrained spaces.
Startup procedures should follow the Eaton installation guide for the RV48M28F4916PDSD, ensuring correct wiring of primary and secondary breakers and proper coordination with existing protective relays. Use compatible protection settings to optimize fault isolation, maintain DOE2016 efficiency, and preserve UL-listed safety. A pre-commissioning checklist helps verify insulation, grounding, and clearance requirements before energizing.