Eaton S10N11S05N General purpose encapsulated transformer - UL Listed

Part Number: S10N11S05N
Manufacturer
Eaton
Part number
S10N11S05N

Quick Summary

Eaton General purpose encapsulated transformer provides reliable single-phase power isolation for control panels and industrial equipment. When installation sites demand weather resistance and compact footprint, this unit delivers rugged performance without compromising protection. UL Listed and designed with a NEMA 3R enclosure for indoor-outdoor use, it supports 60 Hz operation and a 5 kVA rating. With primary voltage options of 120/240 V and secondary 120/240 V, it helps simplify wiring and spare parts across mixed fleets. This combination of durability, certification, and standardization translates to lower maintenance costs and faster procurement in demanding facilities.

Product Information

Extended Description

S10N11S05N Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 177, 60 Hz, single-phase, 120 V, 240 V, 120/240 V, NONE, 115 °C rise, 5 KVA, indoor-outdoor, 3E
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S10N11S05N
UPC
786680103070
Product Length/Depth
9.89 in
Product Height
16 in
Product Width
10.38 in
Product Weight
113 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Model N
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
177
Tap size
None
Type
General-Purpose Encapsulated Transformer
Wiring connection
3E
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
120 V, 240 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
5 kVA
Weathershield
Indoor-Outdoor
Feature: Encapsulated epoxy resin (EP) design with aluminum coil. Business Impact: Provides robust protection against moisture, dust, and vibration, reducing field failures. Application: Ideal for harsh factory floors and outdoor installations where reliability matters. Feature: NEMA 3R enclosure. Business Impact: Enables indoor-outdoor service and easier mounting in restricted spaces, lowering enclosure-related risks. Application: Control panels mounted in warehouses, outdoors, or damp environments. Feature: 5 kVA rating at 60 Hz, single-phase. Business Impact: Supports typical control loads with headroom for startup currents, improving uptime and reducing downtime penalties. Application: Machine tools, conveyors, and panel boards in light-to-mid capacity applications. Feature: Primary and secondary 120/240 V configuration. Business Impact: Flexible wiring choices simplify integration with existing power distribution and panel infrastructure. Application: Retrofitting legacy equipment and standardizing across multiple lines. Feature: UL Listed with Weathershield indoor-outdoor capability. Business Impact: Compliance assurance and extended service life in varied environments, reducing regulatory risk. Application: Panels, feeders, and remote devices deployed outdoors or in mixed-use facilities.

Get a Quick Quote for a Eaton S10N11S05N

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S10N11S05N? Enquire Now

FAQs

For proper installation, consider its 113 lb weight, footprint dimensions, and the NEMA 3R enclosure designed for indoor-outdoor use. Ensure clearances per manufacturer guidance, secure mounting on a sturdy base, and proper ventilation. With 3E wiring and aluminum windings, wiring should follow standard practice for single-phase, 60 Hz systems and include appropriate protection devices.
This unit is a single-phase transformer rated at 5 kVA, operating at 60 Hz. Primary voltage options are 120 V or 240 V, and the secondary is 120/240 V. It uses an aluminum coil and has a 115 °C rise, making it suitable for continuous operation in typical industrial control environments with stable voltage delivery.
Yes. The transformer features a NEMA 3R enclosure and Weathershield designation for indoor-outdoor service. UL Listed certification adds regulatory confidence, while the rugged enclosure and weather tolerance enable reliable operation in outdoor control panels, equipment bays, and damp environments.
Key certifications include UL Listed, with a NEMA 3R enclosure rating for indoor-outdoor use. The unit operates at 60 Hz, is a single-phase design, and uses 120/240 V primary and 120/240 V secondary voltages, aligning with common industry standards for control and power distribution equipment.
The encapsulated aluminum-wound construction, rugged EP design, and UL/NEMA-rated enclosure reduce field maintenance and replacement costs. Its reliability in indoor-outdoor environments minimizes downtime, supports longer service intervals, and simplifies spare-part inventories, delivering a favorable total cost of ownership for control panel and equipment fleets.