Eaton S20N11P02SS4X General Purpose Transformer - NEMA 4X

Part Number: S20N11P02SS4X
Manufacturer
Eaton
Part number
S20N11P02SS4X

Quick Summary

The Eaton S20N11P02SS4X general purpose encapsulated transformer provides reliable single‑phase power isolation for industrial control panels. In practice, engineers often contend with harsh environments, space constraints, and maintenance overhead; this unit minimizes those challenges with a rugged, compact design. Notable considerations for compliance and reliability include a NEMA 4X enclosure suitable for indoor-outdoor service, a copper winding core, and a 2 kVA rating that supports medium control loads. This model aligns with common control-power needs while emphasizing durability and installation simplicity, making it a strong fit for modern automation workflows and panel builders seeking robust, long‑life performance.

Product Information

Extended Description

S20N11P02SS4X Eaton: Eaton, general purpose encapsulated transformer, ep single-phase 240 x 480v none 120/240v 115°c 2 kva copper windings 68p4x 3a indoor-outdoor 60 hz
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S20N11P02SS4X
UPC
786680115950
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
41 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Catalog Notes
NEMA 4X Grade 304 stainless steel enclosure.
Coil material
Copper
Design
EP
Enclosure
NEMA 4X
Frame
68P4X
Tap size
None
Type
General-purpose encapsulated transformer
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
240 V, 480 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
2 kVA
Weathershield
Indoor-Outdoor
Feature: Copper windings provide high conductivity and efficient energy transfer. Benefit: Reduced heat buildup and improved efficiency lead to lower operating costs. Application: Ideal for steady-state control circuits in automated lines where reliability matters. Feature: 2 kVA power rating supports medium control loads without oversizing. Benefit: Cost-effective protection against undervoltage and overload while enabling scalable automation. Application: Panel power supplies and signal conditioning in machine rooms. Feature: Copper encapsulated design with EP construction. Benefit: Superior moisture and contaminant resistance, extending service life in challenging environments. Application: Enclosures exposed to dust, humidity, or washdown scenarios. Feature: NEMA 4X stainless steel enclosure. Benefit: Corrosion resistance and outdoor suitability reduce maintenance cycles. Application: Outdoor installations or damp plant areas requiring durable protection. Feature: 60 Hz single-phase operation with primary 240/480 V and secondary 120/240 V. Benefit: Flexible integration with common plant power architectures and simple wiring. Application: Control panels fed from plant mains, supporting reliable low-voltage circuits. Feature: Weathershield supports indoor-outdoor use; 68P4X frame provides compatibility with standard panel layouts. Benefit: Faster installation and universal fit within existing housings. Application: Retrofit projects and new builds alike, for consistent installation footprints.

Get a Quick Quote for a Eaton S20N11P02SS4X

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S20N11P02SS4X? Enquire Now

FAQs

Installers should account for the 41 lb weight and the 68P4X frame when mounting the transformer inside a panel. The NEMA 4X enclosure supports indoor-outdoor usage, reducing corrosion risk in harsh environments. Plan wiring to match the 240/480 V primary and 120/240 V secondary configuration and provide adequate clearance for cooling.
This unit is a single-phase transformer rated at 2 kVA. It supports primary voltages of 240 V and 480 V, with secondary voltages of 120/240 V. It operates at 60 Hz and uses copper windings to deliver efficient power transfer with a 115 °C rise, suitable for typical industrial control loads.
Yes. The enclosure is rated NEMA 4X with a code‑friendly 304 stainless steel construction, providing robust protection in indoor-outdoor settings. This makes it appropriate for environments that require corrosion resistance and washdown capability while maintaining reliable control power.
The product data lists Certifications as 'Contact Manufacturer,' so regulatory approvals should be confirmed with Eaton. In practice, transformers in this class commonly require CE marking and UL/CSA approvals depending on region; verify the exact certifications for your installation with the supplier before procurement.
Encapsulated copper windings and a sealed NEMA 4X enclosure minimize moisture ingress and contaminants, reducing maintenance needs and downtime. The 2 kVA rating provides adequate headroom for control circuits, while the 1‑year warranty offers support for field reliability, contributing to lower lifecycle costs in automation applications.