Eaton S20P11S10CUSS4X General-Purpose Transformer - NEMA 3R

Part Number: S20P11S10CUSS4X
Manufacturer
Eaton
Part number
S20P11S10CUSS4X

Quick Summary

Eaton General purpose encapsulated transformer delivers reliable power isolation for control panels and industrial equipment. In demanding facilities, unsealed or undersized transformers cause unplanned downtime and costly field rework. UL Listed certification and a rugged NEMA 3R enclosure provide safe operation indoors or outdoors, even in dusty or damp environments. The unit's 10 kVA rating with copper windings supports scalable power distribution, while 240/480 V primary and 120/240 V secondary voltages align with standard plant wiring. Designed for ease of installation, the encapsulated EP design and accessible tap settings simplify maintenance and future expansion.

Product Information

Extended Description

S20P11S10CUSS4X Eaton: Eaton General purpose encapsulated transformer, EP, copper, NEMA 3R, 60 Hz, single-phase, 240 V, 480 V, 120/240 V, 1 at +5% FCAN, 2 at -5% FCBN X 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 10 KVA, indoor-outdoor
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S20P11S10CUSS4X
UPC
786680092145
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Grade 304 stainless steel enclosure with NEMA 4X rating
Coil material
Copper
Design
EP
Enclosure
NEMA 3R
Tap size
1 at +5% FCAN, 2 at -5% FCBN x 2 at +2.5% FCAN, 4 at -2.5% FCBN
Type
General-Purpose Encapsulated Transformer
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
240 V, 480 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
10 kVA
Weathershield
Indoor-Outdoor
Feature: Copper windings provide high electrical conductivity and thermal stability. Business Impact: Higher efficiency with lower copper losses and more predictable temperature rise, reducing cooling needs and energy costs. Application: Suitable for 60 Hz single-phase power distribution in machine control panels and distributed plant power. Feature: NEMA 3R enclosure with indoor-outdoor capability. Business Impact: Weather resistance and durable protection from dust, rain, and humidity, lowering enclosure costs and downtime. Application: Outdoor substations, outdoor control panels, and harsh factory floors. Feature: Tap settings of 1 at +5% FCAN, 2 at -5% FCBN × 2 at +2.5% FCAN, 4 at -2.5% FCBN. Business Impact: On-site voltage regulation minimizes voltage drop and protects connected equipment, reducing failure rates. Application: Fine-tuned transformer performance in fluctuating supply conditions. Feature: 10 kVA rating. Business Impact: Scalable power for multiple loads from a single transformer, decreasing footprint and installation complexity. Application: Small-to-medium control panels and distributed power networks. Feature: 60 Hz, single-phase design with 240 V and 480 V primary, 120/240 V secondary. Business Impact: Direct compatibility with common plant wiring, simplifying integration and reducing retrofit time. Application: Industrial automation systems and machine tools. Feature: UL Listed certification. Business Impact: Regulatory compliance and supplier trust, accelerating procurement and maintenance planning. Application: Safety-minded installations in industrial environments.

Get a Quick Quote for a Eaton S20P11S10CUSS4X

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S20P11S10CUSS4X? Enquire Now

FAQs

Install on a rigid, vibration-free base inside a compliant enclosure. Use the NEMA 3R-rated enclosure for indoor-outdoor environments, connect primary windings to 240 V or 480 V as needed, and wire the 120/240 V secondary to the load. Ensure proper grounding and verify the tap settings match your supply voltage under load.
The transformer is a 10 kVA, single-phase unit with 60 Hz frequency. Primary voltages are 240 V and 480 V, secondary voltage is 120/240 V, copper windings are used, and it has a 115 °C rise. It features multiple tap settings and a NEMA 3R enclosure rated for indoor-outdoor use.
Yes. It uses a NEMA 3R enclosure designed for indoor-outdoor service and UL Listed safety certification, making it well-suited for rugged control panels, machine rooms, and outdoor equipment exposed to dust, moisture, or temperature variation.
This model is UL Listed, ensuring compliance with recognized safety standards. The NEMA 3R enclosure rating further confirms suitability for outdoor and semi-protected installations, improving reliability and simplifying regulatory acceptance in industrial facilities.
Copper windings and robust encapsulation minimize heat and insulation wear, extending service life. The 10 kVA rating supports multiple loads from a single transformer, reducing footprint and installation costs, while voltage tap settings help maintain equipment performance, reducing maintenance downtime and energy waste.