Eaton S26N11S10 General-Purpose Transformer - UL Listed
Part Number: S26N11S10
Quick Summary
The Eaton S26N11S10 general-purpose encapsulated transformer provides reliable power conditioning for rugged industrial panels. Plant floor environments contend with moisture, vibration, and voltage swings that can upset controls; this unit’s NEMA 3R enclosure and 60 Hz operation help stabilize performance and uptime. UL Listed certification demonstrates safety compliance for regulated facilities, while indoor-outdoor capability and aluminum windings support durable service across demanding environments. The 270 V primary and 120/240 V secondary arrangement enables seamless power distribution, reducing wiring changes and enabling smooth integration with existing automation architectures. From installation to ongoing maintenance, this transformer supports efficient power management and distribution strategies, aligning with industry best practices for reliability and cost-of-ownership.
Product Information
Extended Description
S26N11S10 Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 179, 60 Hz, single-phase, 270 V, 120/240 V, NONE, 115 °C rise, 10 KVA, indoor-outdoor, 524Y
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S26N11S10
UPC
786680090974
Product Length/Depth
10.52 in
Product Height
19 in
Product Width
13.38 in
Product Weight
215 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
179
Tap size
None
Type
General-Purpose Encapsulated Transformer
Wiring connection
524Y
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
270 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
10 kVA
Weathershield
Indoor-Outdoor
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton Specification Sheet - S26N11S10
Selling Policy 25-000 - Distribution and Control Products and Services
General design and construction: The EP encapsulated enclosure with aluminum windings protects against moisture and corrosion, delivering long service life in harsh indoor-outdoor plant environments. This configuration reduces maintenance costs and field failures, particularly for outdoor control panels, building relays, and rugged automation cabinets that operate under severe weather, vibration, and transient power conditions. By combining a robust sealing system, efficient heat dissipation, and a flexible mounting footprint, it supports dependable operation in evolving facilities and streamlines retrofit projects for aging infrastructure. Electrical ratings and efficiency: The unit operates at 60 Hz with a 270 V primary and 120/240 V secondary, rated at 10 kVA, providing ample headroom for multiple circuits and serving as a reliable power source for PLCs, relays, and low-voltage controls. This arrangement delivers stable control voltages, minimizes feeder voltage drop, and improves PLC reliability in automation cabinets and distributed control ecosystems across manufacturing lines. In practice, the 10 kVA rating enables a single transformer to serve several relays and sensors, reducing wiring complexity, panel space, and overall capital cost while improving fault tolerance. Wiring and installation specifics: Wiring connection uses 524Y, with a frame designation of 179, enabling straightforward mounting and routing in mid-size control enclosures and serviceable access for future upgrades. The transformer is designed for indoor-outdoor use under the NEMA 3R enclosure, simplifying installation in exposed locations without extra weatherproof housings and enabling safer operation in damp or dusty environments. Compatibility with common Eaton power distribution components accelerates commissioning, lowers install risk, and ensures consistent performance across panels that share a standard 524Y wiring scheme. Safety and compliance: UL Listed certification verifies compliance with electrical safety standards for regulated facilities, while the enclosure protects sensitive windings from moisture, dust, and incidental contact in harsh environments. The device carries a 115 °C rise specification that informs thermal management planning and cooling strategies in crowded electrical rooms and high-duty cycles. Weathershield compatibility and aluminum windings further improve reliability during temperature and humidity swings typical of industrial environments and extended duty operation. Practical deployment insights: Designed to integrate with Eaton's broader power management and distribution ecosystem, the S26N11S10 supports modular expansion and reduces the transformer count needed in larger facilities, improving maintenance scheduling and spare-part inventory. Field feedback highlights quicker commissioning, steadier control voltage, and fewer field interventions compared with loose-core or multi-transformer setups, which translates to lower downtime and higher plant throughput. This general-purpose encapsulated transformer thus aligns with typical ROI expectations for panel upgrades, automation line expansions, and new equipment that require dependable, versatile power conditioning.
Get a Quick Quote for a Eaton S26N11S10
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton S26N11S10?
Enquire Now
FAQs
Plan for the 270 V to 120/240 V conversion in a panel with a NEMA 3R enclosure; ensure sufficient clearance and ventilation for heat dissipation; use the 524Y wiring scheme and 179 frame mounting to simplify routing and future upgrades.
Single-phase, 60 Hz, primary 270 V, secondary 120/240 V, 10 kVA rating, aluminum windings, wiring connection 524Y, enclosure NEMA 3R, temperature rise 115 °C, frame 179.
Yes. The NEMA 3R enclosure and indoor-outdoor capability provide environmental protection, UL Listed safety certification ensures compliance, and the 115 °C rise informs thermal management for demanding duty cycles.
UL Listed certification confirms electrical safety compliance for regulated facilities, while NEMA 3R enclosure design supports rugged indoor-outdoor use, enabling safer operation in varied environments without additional weatherproofing.
The robust encapsulated design reduces field failures and maintenance visits, lowers spare-part counts, and improves uptime in automation lines, contributing to a favorable ROI through reduced downtime and streamlined panel upgrades.