Eaton S29N11S82 General-Purpose Transformer - UL Listed

Part Number: S29N11S82
Manufacturer
Eaton
Part number
S29N11S82

Quick Summary

Eaton S29N11S82 General-Purpose Transformer converts 208V to 120/240V for control circuits in industrial panels. Engineers often struggle with compact, weatherproof transformers that fit tight spaces and resist outdoor exposure. It’s UL Listed for safety and reliability, with a rugged NEMA 3R enclosure that supports indoor-outdoor installations. Designed for Eaton ecosystems, this encapsulated transformer delivers a small, weight-conscious solution for low-voltage control circuits and panel mounting, helping reduce installation complexity and lifecycle costs.

Product Information

Extended Description

S29N11S82 Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 54, 60 Hz, single-phase, 208 V, 120/240 V, NONE, 115 °C rise, 0.1 KVA, indoor-outdoor, 26A
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S29N11S82
UPC
786680068386
Product Length/Depth
4 in
Product Height
8.91 in
Product Width
4.11 in
Product Weight
8 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
54
Tap size
None
Type
General-Purpose Encapsulated Transformer
Wiring connection
26A
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
208 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Volt ampere rating
0.1 kVA
Weathershield
Indoor-Outdoor
Feature → Business Impact → Application: The transformer uses an aluminum coil in a compact 54-frame enclosure, delivering reliable voltage conversion at 0.1 kVA while weighing just 8 lb. This combination reduces installation time and supports space-constrained panels in industrial environments, lowering total cost of ownership and improving panel density. Feature → Application: No taps (tap size is None) simplifies setup and minimizes maintenance concerns in environments with stable supply voltage, while still delivering consistent performance for automation equipment and small machines. Feature → Business Impact → Application: NEMA 3R rated enclosure provides indoor-outdoor protection, enabling safe operation in wet or dusty service areas and reducing enclosure-related failures in outdoor controller housings. Feature → Application: The single-phase, 60 Hz rating with 208 V primary and 120/240 V secondary aligns with common control circuits in factories, facilitating straightforward integration with standard automation gear and power distribution systems. Feature → Business Impact → Application: UL Listed certification ensures compliance and confidence for procurement teams, supporting quality audits and reducing vendor risk in project rollouts. Feature → Application: Lightweight and compact form factor improves transportability and reduces shipping costs, while the encapsulated design minimizes noise and moisture ingress in noisy industrial environments.

Get a Quick Quote for a Eaton S29N11S82

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S29N11S82? Enquire Now

FAQs

Install the S29N11S82 in a suitable enclosure with adequate clearance for the 54 frame and 8 lb weight. Connect the primary 208V to the designated input terminals and attach the 120/240V secondary to the control circuits. Since there are no taps, ensure the input voltage remains stable to avoid rating deviations. Use proper insulation and follow all local codes for indoor-outdoor installations.
The unit features a NEMA 3R enclosure that protects against moisture and dust, allowing safe operation in exposed locations. Its UL Listed certification confirms safety compliance, while the aluminum coil provides robust durability. Together, these factors enable reliable performance in environments where weather and contamination could impact traditional transformers.
This is a single-phase transformer with a primary voltage of 208 V and a secondary voltage of 120/240 V. The voltage rating is 0.1 kVA, operating at 60 Hz with a temperature rise of 115 °C. It uses a 26 A wiring connection and has no taps, making it straightforward for fixed-voltage control applications in standard automation setups.
The transformer follows Eaton’s warranty policy 25-000, providing one year from installation or eighteen months from shipment, whichever comes first. This warranty supports lower long-term maintenance risk and helps justify the initial value by protecting against early-life defects in mission-critical control circuits.
Prioritize a clean, dry mounting surface for the NEMA 3R enclosure and ensure adequate ventilation to manage the 115 °C rise under load. With aluminum coil construction and a compact 4 x 8.91 x 4.11 inch footprint, plan for limited space in panel layouts. Confirm compatibility with existing Eaton power management components to maximize performance and simplify future upgrades.