Eaton Encapsulated Transformer S29N48S05CUSS4X - NEMA4X

Part Number: S29N48S05CUSS4X
Manufacturer
Eaton
Part number
S29N48S05CUSS4X

Quick Summary

The Eaton Encapsulated Transformer S29N48S05CUSS4X provides reliable power isolation and voltage conversion for industrial control panels and machinery. This general-purpose encapsulated design protects windings and connections in demanding environments, reducing downtime and maintenance. Many facilities struggle with moisture ingress, dust, and harsh conditions that shorten transformer life; this unit's NEMA 4X enclosure and copper windings are purpose-built to withstand those challenges. With a 5 kVA rating at 60 Hz and a single-phase configuration, it supports dependable auxiliary power for controls, sensors, and drives. The indoor-outdoor capability and Eaton warranty provide practical business value and long-term asset protection, complementing your existing power distribution strategy.

Product Information

Extended Description

S29N48S05CUSS4X Eaton: Eaton General purpose encapsulated transformer, EP, copper, NEMA 4X, 60 Hz, single-phase, 208 V, 480 V, None, 150 °C rise, 5 KVA, indoor-outdoor
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S29N48S05CUSS4X
UPC
786680096556
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Catalog Notes
NEMA 4X Grade 304 stainless steel enclosure.
Coil material
Copper
Design
EP
Enclosure
NEMA 4X
Tap size
None
Type
General-purpose encapsulated transformer
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
208 V
Secondary Voltage
480 V
Temperature rise
150 °C rise
Volt ampere rating
5 kVA
Weathershield
Indoor-Outdoor
Feature Copper windings and EP design → Business impact: High efficiency and durability under load transients reduce energy losses and maintenance costs; Application: Control panels and automation cabinets in mid-to-high demand environments. Feature NEMA 4X enclosure with indoor-outdoor capability (NEMA 4X Grade 304 stainless steel enclosure per catalog notes) → Business impact: Weatherproof and corrosion-resistant protection lowers downtime in outdoor or washdown areas; Application: Outdoor enclosures and harsh factory floors. Feature 208 V primary to 480 V secondary with 5 kVA rating → Business impact: Flexible integration with common industrial power systems and sufficient mid-range power for drives and sensors; Application: Machine tools, conveyors, and automation equipment. Feature Copper windings and 150 °C rise rating → Business impact: Robust thermal performance supports stable operation in temperature-varied facilities; Application: Industrial plants with fluctuating ambient temperatures. Feature No taps and single-phase 60 Hz operation → Business impact: Simplified installation and compatibility with existing 208/480 V infrastructure; Application: Replacement in legacy control panels and modular power distribution. Feature Warranty and support → Business impact: Clear coverage reduces lifecycle risk and simplifies procurement within the Eaton ecosystem; Application: Asset protection for mission-critical control architectures.

Get a Quick Quote for a Eaton S29N48S05CUSS4X

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S29N48S05CUSS4X? Enquire Now

FAQs

When installing the S29N48S05CUSS4X, provide a clean, dry cabinet with adequate clearance for ventilation and heat dissipation. Mount the unit in a location that supports its indoor-outdoor NEMA 4X rating, connect a 208 V supply to the primary and route the 480 V secondary to the load with proper overcurrent protection. Ensure the enclosure remains closed during operation to preserve its weatherproof and dust-resistant benefits. Adhere to local code requirements and Eaton installation guidelines for optimal performance.
Key specs include 5 kVA rating, 60 Hz frequency, single-phase design, 208 V primary, 480 V secondary, copper windings, and a 150 °C temperature rise. The enclosure is NEMA 4X for indoor-outdoor use, and the unit is designed for reliable operation in demanding environments. Verify installation wiring, protective devices, and clearances match these ratings to ensure safe, efficient operation.
Yes. The transformer features a NEMA 4X enclosure with indoor-outdoor protection, making it suitable for outdoor installations and washdown areas where moisture, dust, or corrosion could affect performance. This rugged design helps extend service life and reduces the frequency of enclosure maintenance in harsh environments.
Warranty details mirror Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. For certifications or specific service support, contact the manufacturer. This coverage supports asset reliability and provides a clear path for returns, replacements, or repairs if needed within the warranty period.
This transformer excels in control panels, automation cabinets, conveyors, pumps, and other factory power distribution needs where 208 V to 480 V stepping is required. Its rugged NEMA 4X enclosure and copper windings deliver dependable power for mid-range loads, enabling safer, more efficient control systems in industrial settings.