Eaton S48G11B16 General-Purpose Transformer - UL Listed

Part Number: S48G11B16
Manufacturer
Eaton
Part number
S48G11B16

Quick Summary

Eaton S48G11B16 is a general‑purpose encapsulated transformer that provides 120/240 V secondary from a 480 V primary for control panels. In many industrial builds, voltage mismatches and exposed equipment raise safety risks and downtime; this unit addresses both with proven isolation and rugged construction. It carries UL Listed safety certification and features a NEMA 3R enclosure suitable for indoor-outdoor service, ensuring compliant, durable operation across environments. With a 1.5 kVA rating and aluminum coil, it delivers reliable power without oversizing, while its compact footprint supports flexible panel layouts and easier installation, reducing overall project cost and downtime.

Product Information

Extended Description

S48G11B16 Eaton: Eaton General purpose encapsulated transformer, EP, aluminum, NEMA 3R, 68, 60 Hz, single-phase, 480 V, 120/240 V, 2 at -5% FCBN, 80 °C rise, 1.5 KVA, indoor-outdoor, 2D
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S48G11B16
UPC
786680071645
Product Length/Depth
6.52 in
Product Height
13.41 in
Product Width
6.37 in
Product Weight
45 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Design
EP
Enclosure
NEMA 3R
Frame
68
Tap size
2 at -5% FCBN
Type
General-Purpose Encapsulated Transformer
Wiring connection
2D
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
480 V
Secondary Voltage
120/240 V
Temperature rise
80 °C rise
Volt ampere rating
1.5 kVA
Weathershield
Indoor-Outdoor
Feature: 1.5 kVA, 480 V primary, 120/240 V secondary, 60 Hz, single-phase. Benefit: Adequate, scalable power for automation and control circuits without oversized equipment. Application: Control panels and small process equipment that require consistent voltage conversion with efficiency. In practice, this means fewer components to manage and lower heat generation inside enclosures. Feature: NEMA 3R enclosure with indoor-outdoor suitability. Benefit: Weather-resistant performance and versatile placement in factories, warehouses, or exterior locations. Application: Outdoor timer modules, exterior feeders, and process lines where environmental exposure is a factor, reducing enclosure changes and maintenance. Feature: Tap size 2 at -5% FCBN. Benefit: Built-in voltage regulation to accommodate supply variations and maintain stable secondary voltage. Application: Sites with fluctuating mains where voltage droop could impact performance of sensors and controllers. Feature: Aluminum coil construction. Benefit: Lightweight, corrosion-resistant windings that improve service life and ease handling during installation. Application: OEM panels and retrofit scenarios where weight and durability matter for field crews. Feature: Weathershield indoor-outdoor capability with a rugged design. Benefit: Extended operating life in challenging environments with fewer replacement cycles. Application: Industrial environments, service bays, and outdoor equipment housings where reliability is critical. Feature: UL Listed and compact dimensions (6.52 in L, 6.37 in W, 13.41 in H). Benefit: Clear compliance and space-efficient panel design; easier integration with standard mounting patterns. Application: New builds and retrofits aiming for safe, standards-aligned power distribution.

Get a Quick Quote for a Eaton S48G11B16

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S48G11B16? Enquire Now

FAQs

For installation, ensure a space that accommodates its 6.52 in depth, 6.37 in width, and 13.41 in height with a 45 lb weight. Use 2D wiring, mount in a protected enclosure, and respect the NEMA 3R indoor-outdoor rating for safe service. The -5% FCBN tap should be used to address voltage variations when the supply fluctuates.
The transformer provides 1.5 kVA at 60 Hz, single-phase, with a 480 V primary input and a 120/240 V secondary output. It features aluminum windings and a temperature rise of 80 °C, suitable for typical industrial control circuits and automation equipment.
Yes. The S48G11B16 uses a NEMA 3R enclosure rated for indoor-outdoor service, along with a rugged design and UL Listed safety certification, making it a reliable choice for panels exposed to varying environmental conditions.
The transformer is UL Listed, ensuring conformity with safety standards for electrical equipment. The NEMA 3R enclosure further supports compliant operation in both indoor and outdoor locations, helping to reduce regulatory risk and streamline approvals for industrial installations.
Warranty is Eaton’s policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. This protects against manufacturing defects and supports lower total cost of ownership by reducing unplanned maintenance and downtime.