Eaton S48M11S50CUSS4X Encapsulated Transformer - NEMA 4X

Part Number: S48M11S50CUSS4X
Manufacturer
Eaton
Part number
S48M11S50CUSS4X

Quick Summary

The Eaton S48M11S50CUSS4X encapsulated transformer delivers safe, reliable power for industrial control panels. In harsh facilities, corrosion, moisture ingress, and retrofit constraints erode uptime and increase maintenance costs. With a NEMA 4X enclosure and Grade 304 stainless steel construction, copper windings, and a 60 Hz 480 V to 120/240 V configuration, it tolerates outdoor and wash-down environments while simplifying integration. Designed for indoor-outdoor service, it streamlines installation and minimizes field modifications, delivering consistent performance and long service life for power management in automation systems.

Product Information

Extended Description

S48M11S50CUSS4X Eaton: Eaton General purpose encapsulated transformer, EP, copper, NEMA 4X, 60 Hz, single-phase, 480 V, 120/240 V, 2 at +2.5% FCAN 4 at -2.5% FCBN, 150 °C rise, 50 KVA, indoor-outdoor
Product Name
Eaton General purpose encapsulated transformer
Catalog Number
S48M11S50CUSS4X
UPC
786680079900
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Catalog Notes
NEMA 4X Grade 304 stainless steel enclosure.
Coil material
Copper
Design
EP
Enclosure
NEMA 4X
Tap size
2 at +2.5% FCAN 4 at -2.5% FCBN
Type
General-purpose encapsulated transformer
Frequency rating
60 Hz
Phase
Single-phase
Primary voltage
480 V
Secondary Voltage
120/240 V
Temperature rise
150 °C rise
Volt ampere rating
50 kVA
Weathershield
Indoor-Outdoor
Feature copper windings and an EP encapsulated design → Business impact: reduced leakage, improved thermal performance, and higher efficiency under load → Application: control panels and automation cabinets where space is tight and reliability matters. Feature NEMA 4X Grade 304 stainless enclosure → Business impact: corrosion resistance and water ingress protection across indoor-outdoor sites → Application: outdoor substations, wash-down areas, and harsh manufacturing environments. Feature 50 kVA rating with primary 480 V and secondary 120/240 V → Business impact: adequate headroom for machine tools and control circuits, enabling fewer feeders and simplified wiring → Application: power distribution within equipment enclosures and distributed automation racks. Feature 60 Hz single-phase operation → Business impact: plug-and-play compatibility with standard plant power, reducing engineering time → Application: general-purpose use in industrial automation and packaging lines. Feature voltage taps: 2 at +2.5% and 4 at -2.5% FCBN FCAN → Business impact: precise voltage regulation under varying loads → Application: sensitive drives and PLC-powered systems requiring tight voltage control. Feature indoor-outdoor Weathershield capability → Business impact: versatile deployment reduces need for duplicate enclosures → Application: mixed environments where space and protection are critical.

Get a Quick Quote for a Eaton S48M11S50CUSS4X

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton S48M11S50CUSS4X? Enquire Now

FAQs

Plan for appropriate mounting clearance, accessible lead connections, and proper isolation from vibration. The unit uses a 480 V primary and 120/240 V secondary in a single-phase configuration, housed in a NEMA 4X enclosure suitable for indoor-outdoor use. Ensure compatible panel spaces and secure mounting to a solid base, with proper grounding and clear labeling to meet plant safety standards.
Yes. The transformer features a NEMA 4X enclosure with Grade 304 stainless steel construction, designed for indoor-outdoor service and resistance to corrosion in wash-downs and harsh environments. While it’s robust, verify ambient conditions and provide appropriate protection from direct, extreme exposure if needed, following Eaton installation guidelines.
Voltage regulation is provided via taps: two at +2.5% (FCAN) and four at -2.5% (FCBN). This allows fine-tuning of the secondary voltage under load to maintain PLC and drive stability. Installers should follow the manufacturer’s wiring diagram, ensure secure tap connections, and perform voltage measurements with loaded equipment to confirm target voltages within tolerance.
Certifications are listed as Contact Manufacturer. The unit complies with practical standards for power distribution devices, including a 60 Hz single-phase design, copper windings, and a NEMA 4X enclosure suitable for indoor-outdoor use. For formal certification documentation (CE, SIL, etc.), consult Eaton to confirm the exact approvals for your region and application.
The S48M11S50CUSS4X uses copper windings and a robust encapsulated design to reduce losses and leakage, delivering reliable uptime and predictable performance. With a 50 kVA rating, it supports critical control circuits and automation panels, lowering field wiring changes. The unit’s durable enclosure lowers maintenance needs in harsh environments, contributing to favorable total cost of ownership over its service life.